58 research outputs found

    Novacor left ventricular assist system versus heartmate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: A prospective study

    Get PDF
    AbstractObjective: Long-term mechanical circulatory support as a bridge-to-transplantation procedure and bridge to recovery is of increasing importance. The implantable left ventricular assist devices, Novacor N100 left ventricular assist system (Baxter Healthcare Corporation, Berkeley, Calif) and TCI HeartMate vented electric left ventricular assist system (Thermo Cardiosystems Inc, Woburn, Mass), have proved to be efficient devices in bridge-to-transplantation settings and for prolonged support. The two systems were compared with regard to reliability and morbidity. Methods: Between October 1996 and March 1998, a prospective, single-center study was done that included 40 patients, 20 of whom were treated with the Novacor system and 20 of whom were treated with the HeartMate device. The diseases were mainly dilated cardiomyopathy (13/9) and ischemic cardiomyopathy (6/10). There were no statistically significant differences between the two groups regarding age, sex, preoperative clinical blood chemistry values, hemodynamic data, or risk factors. Results: There were no statistically significant differences between the two groups with regard to postoperative hemodynamics, organ recovery, out-of-hospital support, and survival to heart transplantation. Mean duration of support was 235.3 ± 210 days for the Novacor group and 174.6 ± 175 days for the HeartMate group and mean out-of-hospital support was 241 ± 179 days and 166 ± 152 days for the two groups, respectively. Neurologic complications occurred significantly more often among the Novacor group, whereas the HeartMate group had a higher prevalence of infections and technical problems, which was statistically significant. Survival to transplantation was 65% for the Novacor group and 60% for the HeartMate group. Conclusions: Most patients had organ recovery with left ventricular assist system support, and a considerable number of patients in both groups underwent transplantation. However, both devices need revision to address the current problems, that is, thromboembolism for the Novacor device and infection and reliability for the HeartMate device. (J Thorac Cardiovasc Surg 2000;119:581-7

    First Observation of Self-Amplified Spontaneous Emission in a Free-Electron Laser at 109 nm Wavelength

    Get PDF
    We present the first observation of Self-Amplified Spontaneous Emission (SASE) in a free-electron laser (FEL) in the Vacuum Ultraviolet regime at 109 nm wavelength (11 eV). The observed free-electron laser gain (approx. 3000) and the radiation characteristics, such as dependency on bunch charge, angular distribution, spectral width and intensity fluctuations all corroborate the existing models for SASE FELs.Comment: 6 pages including 6 figures; e-mail: [email protected]

    Geriatric patients' expectations of their physicians: findings from a tertiary care hospital in Pakistan

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Geriatric health is a neglected and under-explored area internationally and in Pakistan. We aimed to ascertain the expectations of the geriatric patients from their physicians and the factors associated with patient satisfaction in this particular age bracket.</p> <p>Methods</p> <p>A cross-sectional survey was carried out at a tertiary care teaching hospital in Karachi, Pakistan. Data collection was carried out via face-to-face interviews based on structured, pre-tested questionnaires. All consenting individuals aged 65 years or above were recruited into the study. Convenience sampling was used to draw the sample. The data was analyzed using SPSS version 16. Geriatric patient's expectations from physicians were elicited using a set of 11 questions that were graded on a scale of 1-3 where 1 = not important, 2 = important, 3 = very important.</p> <p>Results</p> <p>Three hundred and eighty geriatric patients were interviewed. The response rate of this study was 89.8%. The mean age of the respondents was 73.4 ± 6.8 years. Two hundred and forty eight respondents (65.3%) were female. Diabetes mellitus (53.7%), hypertension (59.5%), arthritis (40.5%) and renal disease (32.1%) were common ailments among geriatric patients. More than 50% of the patients were visiting their physicians once every two to three months. Discussing treatment options and letting patients make the final decision (79.2%), prescribing minimum possible medications (84.5%), physician's holistic knowledge about the spectrum of care issues for geriatric patients (79.2%), being given a realistic but optimistic picture of future health by physicians (85.5%) were ranked as very important expectations by patients from their physicians. Cumulative household income (p = 0.005), most important health complaint (p = 0.01) and frequency of experiencing health complaint (p < 0.001) emerged as independent predictors of the satisfaction of geriatric patients from care provided by physicians.</p> <p>Conclusion</p> <p>We have documented the expectations of the geriatric patients from their physicians in a developing country. Physicians belonging to all disciplines should keep these expectations in mind during clinical encounters with geriatric patients.</p

    Is music enriching for group-housed captive chimpanzees (Pan troglodytes)?

    Get PDF
    Many facilities that house captive primates play music for animal enrichment or for caregiver enjoyment. However, the impact on primates is unknown as previous studies have been inconclusive. We conducted three studies with zoo-housed chimpanzees (Pan troglodytes) and one with group-housed chimpanzees at the National Centre for Chimpanzee Care to investigate the effects of classical and pop/rock music on various variables that may be indicative of increased welfare. Study one compared the behaviour and use of space of 18 animals when silence, classical or pop/rock music was played into one of several indoor areas. Overall, chimpanzees did not actively avoid the area when music was playing but were more likely to exit the area when songs with higher beats per minute were broadcast. Chimpanzees showed significantly fewer active social behaviours when music, rather than silence, was playing. They also tended to be more active and engage in less abnormal behaviour during the music but there was no change to either self-grooming or aggression between music and silent conditions. The genre of music had no differential effects on the chimpanzees’ use of space and behaviour. In the second study, continuous focal observations were carried out on three individuals with relatively high levels of abnormal behaviour. No differences in behaviour between music and silence periods were found in any of the individuals. The final two studies used devices that allowed chimpanzees to choose if they wanted to listen to music of various types or silence. Both studies showed that there were no persistent preferences for any type of music or silence. When taken together, our results do not suggest music is enriching for group-housed captive chimpanzees, but they also do not suggest that music has a negative effect on welfare

    K201 improves aspects of the contractile performance of human failing myocardium via reduction in Ca2+ leak from the sarcoplasmic reticulum

    Get PDF
    In heart failure, intracellular Ca2+ leak from cardiac ryanodine receptors (RyR2s) leads to a loss of Ca2+ from the sarcoplasmic reticulum (SR) potentially contributing to decreased function. Experimental data suggest that the 1,4-benzothiazepine K201 (JTV-519) may stabilise RyR2s and thereby reduce detrimental intracellular Ca2+ leak. Whether K201 exerts beneficial effects in human failing myocardium is unknown. Therefore, we have studied the effects of K201 on muscle preparations from failing human hearts. K201 (0.3 μM; extracellular [Ca2+]e 1.25 mM) showed no effects on contractile function and micromolar concentrations resulted in negative inotropic effects (K201 1 μM; developed tension −9.8 ± 2.5% compared to control group; P < 0.05). Interestingly, K201 (0.3 μM) increased the post-rest potentiation (PRP) of failing myocardium after 120 s, indicating an increased SR Ca2+ load. At high [Ca2+]e concentrations (5 mmol/L), K201 increased PRP already at shorter rest intervals (30 s). Strikingly, treatment with K201 (0.3 μM) prevented diastolic dysfunction (diastolic tension at 5 mmol/L [Ca2+]e normalised to 1 mmol/L [Ca2+]e: control 1.26 ± 0.06, K201 1.01 ± 0.03, P < 0.01). In addition at high [Ca2+]e, K201 (0.3 μM) treatment significantly improved systolic function [developed tension +27 ± 8% (K201 vs. control); P < 0.05]. The beneficial effects on diastolic and systolic functions occurred throughout the physiological frequency range of the human heart rate from 1 to 3 Hz. Upon elevated intracellular Ca2+ concentration, systolic and diastolic contractile functions of terminally failing human myocardium are improved by K201

    The Heater–Cooler Unit—A Conceivable Source of Infection

    No full text
    Even drinking water is contaminated with pathogenic microorganisms. This does not necessarily pose a risk for healthy individuals, but it may result in serious consequences in people with impaired immune systems. This is particularly valid if drinking water is used for medical purposes. The heater–cooler unit (HCU) connected to heat exchangers or blankets by tubing, the connection is closed water circuit that contains microorganisms and algae. While connecting the tubing to the heat exchanger, spilling of water cannot be avoided. Microbiological examinations showed that germs and particles pollute the units. Exposure to the patient and the OR equipment has the potential to increase the risk of infection should the HCU water come in contact with the patient. As a result of the high incidence of particle and algae in the HCU, malfunction occurs. Sampling shows >1000/mL CFU (colony forming units) at 36°C and 55/mL CFU at 20°C on average. The specific findings include Pseudomonas and Legionella. Disinfecting HCU is very difficult. Often HCUs do not provide any technology to reduce bacterial or other contamination. The instructions for use of oxygenators often exclude the use of disinfectants. Maintenance instructions for the HCU advocate the use of disinfectants that carry the risk of oxygenator damage and of heat exchanger leakage. The effect of chemical disinfectants and heat exchanger membranes have not been examined, they may impair heat exchanger permeability and function. As an alternative to chemical and thermal disinfection, we used the alternative method of filtration. Using a membrane filter element, we noticed a decreasing number of CFUs from 55 to sterile conditions at 20°C and from >1000 CFUs to 100 CFUs at 36°C (Figure 1). In addition, we noticed a removal of other particles and algae. In conclusion, we have demonstrated a technique that is simple to implement and effectively reduces the microbiological load of the water in the heater– cooler unit
    corecore