619 research outputs found

    A comparative DFT study of electronic properties of 2H-, 4H- and 6H-SiC(0001) and SiC(000-1) clean surfaces: Significance of the surface Stark effect

    Full text link
    Electric field, uniform within the slab, emerging due to Fermi level pinning at its both sides is analyzed using DFT simulations of the SiC surface slabs of different thickness. It is shown that for thicker slab the field is nonuniform and this fact is related to the surface state charge. Using the electron density and potential profiles it is proved that for high precision simulations it is necessary to take into account enough number of the Si-C layers. We show that using 12 diatomic layers leads to satisfactory results. It is also demonstrated that the change of the opposite side slab termination, both by different type of atoms or by their location, can be used to adjust electric field within the slab, creating a tool for simulation of surface properties, depending on the doping in the bulk of semiconductor. Using these simulations it was found that, depending on the electric field, the energy of the surface states changes in a different way than energy of the bulk states. This criterion can be used to distinguish Shockley and Tamm surface states. The electronic properties, i.e. energy and type of surface states of the three clean surfaces: 2H-, 4H-, 6H-SiC(0001), and SiC(0001ˉ000 \bar{1}) are analyzed and compared using field dependent DFT simulations.Comment: 18 pages, 10 figures, 4 table

    Defects in SiO2 as the possible origin of near interface traps in the SiC∕SiO2 system: A systematic theoretical study

    Get PDF
    A systematic study of the level positions of intrinsic and carbon defects in SiO2 is presented, based on density functional calculations with a hybrid functional in an alpha-quartz supercell. The results are analyzed from the point of view of the near interface traps (NIT), observed in both SiC/SiO2 and Si/SiO2 systems, and assumed to have their origins in the oxide. It is shown that the vacancies and the oxygen interstitial can be excluded as the origin of such NIT, while the silicon interstitial and carbon dimers give rise to gap levels in the energy range inferred from experiments. The properties of these defects are discussed in light of the knowledge about the SiC/SiO2 interface

    Transrectal Prostate Biopsy and Fiducial Marker Placement in a Standart 1.5T Magnetic Resonance Imaging Scanner

    Get PDF
    Cataloged from PDF version of article.Purpose: We investigated the accuracy and feasibility of a system that provides transrectal needle access to the prostate concurrent with 1.5 Tesla MRI which previously has not been possible. Materials and Methods: In 5 patients with previously diagnosed prostate cancer, MRI guided intraprostatic placement of gold fiducial markers (4 procedures) and/or prostate biopsy (3 procedures) was performed using local anesthesia. Results: Mean procedure duration was 76 minutes and all patients tolerated the intervention well. Procedure related adverse events included self-limited hematuria and hematochezia following 3 of 8 procedures (all resolved in less than 1 week). Mean needle placement accuracy was 1.9 mm for the fiducial marker placement studies and 1.8 mm for the biopsy procedures. Mean fiducial marker placement accuracy was 4.8 mm and the mean fiducial marker placement accuracy transverse to the needle direction was 2.6 mm. All patients who underwent the procedure were able to complete their course of radiotherapy without delay or complication. Conclusions: While studies of clinical usefulness are warranted, transrectal 1.5 T MRI guided prostate biopsy and fiducial marker placement is feasible using this system, providing new opportunities for image guided diagnostic and therapeutic prostate interventions

    Monitoring of Tumor Promotion and Progression in a Mouse Model of Inflammation-Induced Colon Cancer with Magnetic Resonance Colonography

    Get PDF
    AbstractEarly detection of precancerous tissue has significantly improved survival of most cancers including colorectal cancer (CRC). Animal models designed to study the early stages of cancer are valuable for identifying molecular events and response indicators that correlate with the onset of disease. The goal of this work was to investigate magnetic resonance (MR) colonography in a mouse model of CRC on a clinical MR imager. Mice treated with azoxymethane and dextran sulfate sodium were imaged by serial MR colonography (MRC) from initiation to euthanasia. Magnetic resonance colonography was obtained with both T1- and T2-weighted images after administration of a Fluorinert enema to remove residual luminal signal and intravenous contrast to enhance the colon wall. Individual tumor volumes were calculated and validated ex vivo. The Fluorinert enema provided a clear differentiation of the lumen of the colon from the mucosal lining. Inflammation was detected 3 days after dextran sulfate sodium exposure and subsided during the next week. Tumors as small as 1.2 mm3 were detected and as early as 29 days after initiation. Individual tumor growths were followed over time, and tumor volumes were measured by MR imaging correlated with volumes measured ex vivo. The use of a Fluorinert enema during MRC in mice is critical for differentiating mural processes from intraluminal debris. Magnetic resonance colonography with Fluorinert enema and intravenous contrast enhancement will be useful in the study of the initial stages of colon cancer and will reduce the number of animals needed for preclinical trials of prevention or intervention

    Isolated oxygen defects in 3C- and 4H-SiC: A theoretical study

    Get PDF
    Ab initio calculations in the local-density approximation have been carried out in SiC to determine the possible configurations of the isolated oxygen impurity. Equilibrium geometry and occupation levels were calculated. Substitutional oxygen in 3C-SiC is a relatively shallow effective mass like double donor on the carbon site (O-C) and a hyperdeep double donor on the Si site (O-Si). In 4H-SiC O-C is still a double donor but with a more localized electron state. In 3C-SiC O-C is substantially more stable under any condition than O-Si or interstitial oxygen (O-i). In 4H-SiC O-C is also the most stable one except for heavy n-type doping. We propose that O-C is at the core of the electrically active oxygen-related defect family found by deep level transient spectroscopy in 4H-SiC. The consequences of the site preference of oxygen on the SiC/SiO2 interface are discussed

    Second harmonic generation in SiC polytypes

    Full text link
    LMTO calculations are presented for the frequency dependent second harmonic generation (SHG) in the polytypes 2H, 4H, 6H, 15R and 3C of SiC. All independent tensor components are calculated. The spectral features and the ratios of the 333 to 311 tensorial components are studied as a function of the degree of hexagonality. The relationship to the linear optical response and the underlying band structure are investigated. SHG is suggested to be a sensitive tool for investigating the near band edge interband excitations.Comment: 12 pages, 10 figure

    D\u27Amico Risk Stratification Correlates with Degree of Suspicion of Prostate Cancer on Multiparametric Magnetic Resonance Imaging.

    Get PDF
    PURPOSE: We determined whether there is a correlation between D\u27Amico risk stratification and the degree of suspicion of prostate cancer on multiparametric magnetic resonance imaging based on targeted biopsies done with our electromagnetically tracked magnetic resonance imaging/ultrasound fusion platform. MATERIALS AND METHODS: A total of 101 patients underwent 3 Tesla multiparametric magnetic resonance imaging of the prostate, consisting of T2, dynamic contrast enhanced, diffusion weighted and spectroscopy images in cases suspicious for or with a diagnosis of prostate cancer. All prostate magnetic resonance imaging lesions were then identified and graded by the number of positive modalities, including low-2 or fewer, moderate-3 and high-4 showing suspicion on multiparametric magnetic resonance imaging. The biopsy protocol included standard 12-core biopsy, followed by real-time magnetic resonance imaging/ultrasound fusion targeted biopsies of the suspicious magnetic resonance lesions. Cases and lesions were stratified by the D\u27Amico risk stratification. RESULTS: In this screening population 90.1% of men had a negative digital rectal examination. Mean±SD age was 62.7±8.3 years and median prostate specific antigen was 5.8 ng/ml. Of the cases 54.5% were positive for cancer on protocol biopsy. Chi-square analysis revealed a statistically significant correlation between magnetic resonance suspicion and D\u27Amico risk stratification (p CONCLUSIONS: Our data support the notion that using multiparametric magnetic resonance prostate imaging one may assess the degree of risk associated with magnetic resonance visible lesions in the prostate

    Inflammatory breast cancer: dynamic contrast-enhanced MR in patients receiving bevacizumab. Initial experience

    Get PDF
    To retrospectively compare three dynamic contrast material-enhanced magnetic resonance (MR) imaging (dynamic MR imaging) analytic methods to determine the parameter or combination of parameters most strongly associated with changes in tumor microvasculature during treatment with bevacizumab alone and bevacizumab plus chemotherapy in patients with inflammatory or locally advanced breast cancer. MATERIALS AND METHODS: This study was conducted in accordance with the institutional review board of the National Cancer Institute and was compliant with the Privacy Act of 1974. Informed consent was obtained from all patients. Patients with inflammatory or locally advanced breast cancer were treated with one cycle of bevacizumab alone (cycle 1) followed by six cycles of combination bevacizumab and chemotherapy (cycles 2-7). Serial dynamic MR images were obtained, and the kinetic parameters measured by using three dynamic analytic MR methods (heuristic, Brix, and general kinetic models) and two region-of-interest strategies were compared by using two-sided statistical tests. A P value of .01 was required for significance. RESULTS: In 19 patients, with use of a whole-tumor region of interest, the authors observed a significant decrease in the median values of three parameters measured from baseline to cycle 1: forward transfer rate constant (Ktrans) (-34% relative change, P=.003), backflow compartmental rate constant extravascular and extracellular to plasma (Kep) (-15% relative change, P<.001), and integrated area under the gadolinium concentration curve (IAUGC) at 180 seconds (-23% relative change, P=.009). A trend toward differences in the heuristic slope of the washout curve between responders and nonresponders to therapy was observed after cycle 1 (bevacizumab alone, P=.02). The median relative change in slope of the wash-in curve from baseline to cycle 4 was significantly different between responders and nonresponders (P=.009). CONCLUSION: The dynamic contrast-enhanced MR parameters Ktrans, Kep, and IAUGC at 180 seconds appear to have the strongest association with early physiologic response to bevacizumab. Clinical trial registration no. NCT0001654
    corecore