31 research outputs found

    Analysis of microbiota associated with peri-implantitis using 16S rRNA gene clone library

    Get PDF
    Background: Peri-implantitis (PI) is an inflammatory disease which leads to the destruction of soft and hard tissues around osseointegrated implants. The subgingival microbiota appears to be responsible for peri-implant lesions and although the complexity of the microbiota has been reported in PI, the microbiota responsible for PI has not been identified. Objective: The purpose of this study was to identify the microbiota in subjects who have PI, clinically healthy implants, and periodontitis-affected teeth using 16S rRNA gene clone library analysis to clarify the microbial differences. Design: Three subjects participated in this study. The conditions around the teeth and implants were evaluated based on clinical and radiographic examinations and diseased implants, clinically healthy implants, and periodontally diseased teeth were selected. Subgingival plaque samples were taken from the deepest pockets using sterile paper points. Prevalence and identity of bacteria was analyzed using a 16S rRNA gene clone library technique. Results: A total of 112 different species were identified from 335 clones sequenced. Among the 112 species, 51 (46%) were uncultivated phylotypes, of which 22 were novel phylotypes. The numbers of bacterial species identified at the sites of PI, periodontitis, and periodontally healthy implants were 77, 57, and 12, respectively. Microbiota in PI mainly included Gram-negative species and the composition was more diverse when compared to that of the healthy implant and periodontitis. The phyla Chloroflexi, Tenericutes, and Synergistetes were only detected at PI sites, as were Parvimonas micra, Peptostreptococcus stomatis, Pseudoramibacter alactolyticus, and Solobacterium moorei. Low levels of periodontopathic bacteria, such as Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans, were seen in peri-implant lesions. Conclusions: The biofilm in PI showed a more complex microbiota when compared to periodontitis and periodontally healthy teeth, and it was mainly composed of Gram-negative anaerobic bacteria. Common periodontopathic bacteria showed low prevalence, and several bacteria were identified as candidate pathogens in PI

    Síndrome de Stevens-Johnson. Apresentação de Caso Clínico

    Get PDF
    Introdução: A Síndrome de Stevens-Johnson (SSJ) é uma doença mucocutânea rara e potencialmente fatal, mais frequente no sexo masculino, cuja incidência aumenta com a idade e em determinados grupos de risco. A SSJ e a Necrólise Tóxica Epidérmica (NET) são duas entidades da mesma doença, com severidade diferente. A etiologia não é clara, mas pensa-se que se deva maioritariamente a reacções adversas a fármacos. Caso clínico: Um jovem de 17 anos de idade, sem antecedentes pessoais relevantes, foi observado no Serviço de Urgência por surgimento de lesões maculopapulares, com 3 dias de evolução, dispersas pela face, cavidade oral, tronco e extremidades, com prostração e taquicardia. Foi internado com o diagnóstico de SSJ. Discussão e Conclusões: O SSJ e a NET têm grande morbilidade e considerável mortalidade. O rápido reconhecimento desta identidade, com a remoção do fármaco desencadeador é essencial. A perda da função de barreira da pele, com a consequente alteração da homeostasia, implica muitas vezes a manutenção da terapêutica de suporte em Unidades de Cuidados Intensivos ou de Queimados.info:eu-repo/semantics/publishedVersio

    A novel non-surgical method for mild peri-implantitis- a multicenter consecutive case series

    No full text
    AIM: The aim of the present study was to evaluate the effect on peri-implant mucosal inflammation from the use of a novel instrument made of chitosan in the non-surgical treatment of mild peri-implantitis across several clinical centers. MATERIALS AND METHODS: In this 6-month multicenter prospective consecutive case series performed in six different periodontal specialist clinics, 63 implants in 63 patients were finally included. The subjects had mild peri-implantitis defined as radiographic bone loss of 1-2 mm, pocket probing depth (PPD) ≥4 mm and a positive bleeding on probing (mBoP) score. The patients were clinically examined at baseline and after 2, 4, 12 and 24 weeks, and radiographs were taken at baseline and at 3 and 6 months. Treatment of the implants with the chitosan brush seated in an oscillating dental drill piece was performed at baseline and at 3 months. Reductions in the clinical parameters (PPD and mBoP) were compared between baseline and the later examination time points. RESULTS: Significant reductions in both PPD and mBoP were observed at all time points compared with the baseline clinical measurements (p < 0.001). The mean PPD and mBoP at baseline were 5.15 mm (4.97; 5.32) and 1.86 (1.78; 1.93), respectively, whereas the mean PPD and mBoP at 6 months were 4.0 mm (3.91; 4.19) and 0.64 (0.54; 0.75), respectively. Stable reductions in PPD and mBoP were evident up to 6 months after the initial treatment and 3 months after the second treatment. All 63 implants were reported to have stable radiographic levels of osseous support. CONCLUSIONS: This case series demonstrated that an oscillating chitosan brush is safe to use and seems to have merits in the non-surgical treatment of dental implants with mild peri-implantitis. To measure the effectiveness of the method, a multicenter randomized clinical trial needs to be undertaken

    Reconstruction of peri-implant osseous defects : a multicenter randomized trial

    Get PDF
    There is a paucity of data for the effectiveness of reconstructive procedures in the treatment of peri-implantitis. The objective of this study was to compare reconstruction of peri-implant osseous defects with open flap debridement (OFD) plus porous titanium granules (PTGs) compared with OFD alone. Sixty-three patients (36 female, 27 male; mean age 58.4 y [SD 12.3]), contributing one circumferential peri-implant intraosseous defect, were included in a multinational, multicenter randomized trial using a parallel-group design. After OFD and surface decontamination using titanium brushes and hydrogen peroxide, 33 defects received PTGs. The implants were not submerged. All patients received adjunctive perioperative systemic antibiotics. The primary outcome variable (defect fill) was assessed on digitalized radiographs. Clinical measurements of probing depth (PPD), bleeding on probing (BoP), suppuration, and plaque were taken by blinded examiners. After 12 mo, the test group (OFD plus PTG) showed a mean radiographic defect fill (mesial/distal) of 3.6/3.6 mm compared with 1.1/1.0 in the control group (OFD). Differences were statistically significant in favor of the test group (P < 0.0001). The OFD plus PTG group showed a mean reduction in PPD of 2.8 mm compared with 2.6 mm in the OFD group. BoP was reduced from 89.4% to 33.3% and from 85.8% to 40.4% for the test and control groups, respectively. There was no significant difference in complete resolution of peri-implantitis (PPD ≤4 mm and no BoP at six implant sites and no further bone loss), because this finding was accomplished at 30% of implants in the test group and 23% of implants in the control group. Reconstructive surgery using PTGs resulted in significantly enhanced radiographic defect fill compared with OFD. However, limitations in the lack of ability to discern biomaterial from osseous tissue could not be verified to determine new bone formation. Similar improvements according to clinical measures were obtained after both surgical treatment modalities (ClinicalTrials.gov NCT02406001)

    Long-term biological complications of dental implants placed either in pristine or in augmented sites: A systematic review and meta-analysis.

    Get PDF
    AIM To investigate and compare the prevalence of biological complications and failure of implants placed in pristine vs. augmented sites after a mean observation period of at least 10 years. MATERIALS AND METHODS The focused question "In patients with osseointegrated dental implants, are there differences in biological complications and implant failure at implants placed in pristine vs. augmented sites?" was addressed using the Population, Exposure, Comparison and Outcome criteria. Electronic and manual searches supplemented by the screening of the grey literature were carried out. A case definition of peri-implant mucositis and peri-implantitis had to be specified. The binary random-effects method was chosen to conduct meta-analyses. Results are presented as Forest plots with weighted mean values and 95% confidence intervals (CI). The I statistic test was applied to quantify heterogeneity. The Newcastle-Ottawa Scale and the parameters provided in the Cochrane Center and CONSORT statement were used for quality assessment. The results are reported according to the PRISMA guidelines. RESULTS No randomized clinical trial (RCT) comparing the outcomes of implants placed in pristine vs. augmented sites was identified. Five case-series studies, one case-control study, one cross-sectional study and one RCT were eligible for qualitative and quantitative analyses. No statistically significant differences (p > .05) were observed between implants placed in pristine vs. augmented sites for any outcome variables both at patient and at implant levels, respectively. High heterogeneity concerning patient sampling, case definitions of biological complications and eligibility criteria was observed. CONCLUSION The studies included in the present systematic review did not directly address the focused questions. Hence, the outcomes of the meta-analysis should be interpreted with caution due to high variability with respect to study design
    corecore