200 research outputs found

    Antipsychotics and Torsadogenic Risk: Signals Emerging from the US FDA Adverse Event Reporting System Database

    Get PDF
    Background: Drug-induced torsades de pointes (TdP) and related clinical entities represent a current regulatory and clinical burden. Objective: As part of the FP7 ARITMO (Arrhythmogenic Potential of Drugs) project, we explored the publicly available US FDA Adverse Event Reporting System (FAERS) database to detect signals of torsadogenicity for antipsychotics (APs). Methods: Four groups of events in decreasing order of drug-attributable risk were identified: (1) TdP, (2) QT-interval abnormalities, (3) ventricular fibrillation/tachycardia, and (4) sudden cardiac death. The reporting odds ratio (ROR) with 95 % confidence interval (CI) was calculated through a cumulative analysis from group 1 to 4. For groups 1+2, ROR was adjusted for age, gender, and concomitant drugs (e.g., antiarrhythmics) and stratified for AZCERT drugs, lists I and II (http://www.azcert.org, as of June 2011). A potential signal of torsadogenicity was defined if a drug met all the following criteria: (a) four or more cases in group 1+2; (b) significant ROR in group 1+2 that persists through the cumulative approach; (c) significant adjusted ROR for group 1+2 in the stratum without AZCERT drugs; (d) not included in AZCERT lists (as of June 2011). Results: Over the 7-year period, 37 APs were reported in 4,794 cases of arrhythmia: 140 (group 1), 883 (group 2), 1,651 (group 3), and 2,120 (group 4). Based on our criteria, the following potential signals of torsadogenicity were found: amisulpride (25 cases; adjusted ROR in the stratum without AZCERT drugs = 43.94, 95 % CI 22.82-84.60), cyamemazine (11; 15.48, 6.87-34.91), and olanzapine (189; 7.74, 6.45-9.30). Conclusions: This pharmacovigilance analysis on the FAERS found 3 potential signals of torsadogenicity for drugs previously unknown for this risk

    The 'help' question doesn't help when screening for major depression: external validation of the three-question screening test for primary care patients managed for physical complaints

    Get PDF
    Major depression, although frequent in primary care, is commonly hidden behind multiple physical complaints that are often the first and only reason for patient consultation. Major depression can be screened by two validated questions that are easier to use in primary care than the full Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) criteria. A third question, called the 'help' question, improves the specificity without apparently decreasing the sensitivity of this screening procedure. We validated the abbreviated screening procedure for major depression with and without the 'help' question in primary care patients managed for a physical complaint. This diagnostic accuracy study used data from the SODA (for 'SOmatisation Depression Anxiety') cohort study conducted by 24 general practitioners (GPs) in western Switzerland that included patients over 18 years of age with at least a single physical complaint at index consultation. Major depression was identified with the full Patient Health Questionnaire. GPs were asked to screen patients for major depression with the three screening questions 1 year after inclusion. Of 937 patients with at least a single physical complaint, 751 were eligible 1 year after index consultation. Major depression was diagnosed in 69/724 (9.5%) patients. The sensitivity and specificity of the two-question method alone were 91.3% (95% CI 81.4 to 96.4) and 65.0% (95% CI 61.2 to 68.6), respectively. Adding the 'help' question decreased the sensitivity (59.4%; 95% CI 47.0 to 70.9) but improved the specificity (88.2%; 95% CI 85.4 to 90.5) of the three-question method. The use of two screening questions for major depression was associated with high sensitivity and low specificity in primary care patients presenting a physical complaint. Adding the 'help' question improved the specificity but clearly decreased the sensitivity; when using the 'help' question, four out of ten patients with depression will be missed, compared to only one out of ten with the two-question method. Therefore, the 'help' question is not useful as a screening question, but may help discussing management strategies

    Assessment of Hyperbolic Heat Transfer Equation in Theoretical Modeling for Radiofrequency Heating Techniques

    Get PDF
    Theoretical modeling is a technique widely used to study the electrical-thermal performance of different surgical procedures based on tissue heating by use of radiofrequency (RF) currents. Most models employ a parabolic heat transfer equation (PHTE) based on Fourier’s theory, which assumes an infinite propagation speed of thermal energy. We recently proposed a one-dimensional model in which the electrical-thermal coupled problem was analytically solved by using a hyperbolic heat transfer equation (HHTE), i.e. by considering a non zero thermal relaxation time. In this study, we particularized this solution to three typical examples of RF heating of biological tissues: heating of the cornea for refractive surgery, cardiac ablation for eliminating arrhythmias, and hepatic ablation for destroying tumors. A comparison was made of the PHTE and HHTE solutions. The differences between their temperature profiles were found to be higher for lower times and shorter distances from the electrode surface. Our results therefore suggest that HHTE should be considered for RF heating of the cornea (which requires very small electrodes and a heating time of 0.6 s), and for rapid ablations in cardiac tissue (less than 30 s)

    A study of the diagnostic accuracy of the PHQ-9 in primary care elderly

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The diagnostic accuracy of the Patient Health Questionnaire-9 (PHQ-9) for assessment of depression in elderly persons in primary care settings in the United States has not been previously addressed. Thus, the purpose of this study was to evaluate the test performance of the PHQ-9 for detecting major and minor depression in elderly patients in primary care.</p> <p>Methods</p> <p>A prospective study of diagnostic accuracy was conducted in two primary care, university-based clinics in the Pacific Northwest of the United States. Seventy-one patients aged 65 years or older participated; all completed the PHQ-9 and the 15-item Geriatric Depression Scale (GDS) and underwent the Structured Clinical Interview for Depression (SCID). Sensitivity, specificity, area under the receiver operating characteristic (ROC) curve, and likelihood ratios (LRs) were calculated for the PHQ-9, the PHQ-2, and the 15-item GDS for major depression alone and the combination of major plus minor depression.</p> <p>Results</p> <p>Two thirds of participants were female, with a mean age of 78 and two chronic health conditions. Twelve percent met SCID criteria for major depression and 13% minor depression. The PHQ-9 had an area under the curve (AUC) of 0.87 (95% confidence interval [CI], 0.74-1.00) for major depression, while the PHQ-2 and the 15-item GDS each had an AUC of 0.81 (95% CI for PHQ-2, 0.64-0.98, and for 15-item GDS, 0.70-0.91; <it>P </it>= 0.551). For major and minor depression combined, the AUC for the PHQ-9 was 0.85 (95% CI, 0.73-0.96), for the PHQ-2, 0.80 (95% CI, 0.68-0.93), and for the 15-item GDS, 0.71 (95% CI, 0.55-0.87; <it>P </it>= 0.187).</p> <p>Conclusions</p> <p>Based on AUC values, the PHQ-9 performs comparably to the PHQ-2 and the 15-item GDS in identifying depression among primary care elderly.</p

    Should methodological filters for diagnostic test accuracy studies be used in systematic reviews of psychometric instruments? a case study involving screening for postnatal depression

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Challenges exist when searching for diagnostic test accuracy (DTA) studies that include the design of DTA search strategies and selection of appropriate filters. This paper compares the performance of three MEDLINE search strategies for psychometric diagnostic test accuracy (DTA) studies in postnatal depression.</p> <p>Methods</p> <p>A reference set of six relevant studies was derived from a forward citation search via Web of Knowledge. The performance of the 'target condition and index test' method recommended by the Cochrane DTA Group was compared to two alternative strategies which included methodological filters. Outcome measures were total citations retrieved, sensitivity, precision and associated 95% confidence intervals (95%CI).</p> <p>Results</p> <p>The Cochrane recommended strategy and one of the filtered search strategies were equivalent in performance and both retrieved a total of 105 citations, sensitivity was 100% (95% CI 61%, 100%) and precision was 5.2% (2.6%, 11.9%). The second filtered search retrieved a total of 31 citations, sensitivity was 66.6% (30%, 90%) and precision was 12.9% (5.1%, 28.6%). This search missed the DTA study with most relevance to the DTA review.</p> <p>Conclusions</p> <p>The Cochrane recommended search strategy, 'target condition and index test', method was pragmatic and sensitive. It was considered the optimum method for retrieval of relevant studies for a psychometric DTA review (in this case for postnatal depression). Potential limitations of using filtered searches during a psychometric mental health DTA review should be considered.</p

    Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating.</p> <p>Methods</p> <p>A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip.</p> <p>Results</p> <p>A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C.</p> <p>Conclusion</p> <p>Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner.</p
    • 

    corecore