7,055 research outputs found

    PERLINDUNGAN KONSUMEN TERHADAP MAKANAN JAJANAN YANG MENGANDUNG FORMALIN DAN BORAKS(SUATU PENELITIAN DI KOTA BANDA ACEH)

    Get PDF
    ABSTRAKNANDA MAULINA SAFIRA,PERLINDUNGAN KONSUMEN TERHADAP 2014MAKANAN JAJANAN YANG MENGANDUNG FORMALIN DAN BORAKS (Studi Penelitian di Kota Banda Aceh)Fakultas Hukum Universitas Syiah Kuala(iv, 63) pp., tabl., bibl., appdx.( RISMAWATI, S.H., M.Hum. )Dalam Pasal 4 huruf a Undang-Undang Perlindungan Konsumen dijelaskan bahwa konsumen memiliki hak atas keselamatan dalam mengkonsumsi barang. Dalam Pasal 67 Undang-Undang Nomor 18 Tahun 2012 tentang Pangan dijelaskan bahwa ketentuan keamanan pangan diselenggarakan untuk menjaga pangan tetap aman dikonsumsi, sehingga terhindar dari kemungkinan cemaran biologis atau kimia yang dapat membahayakan kesehatan manusia. Dalam Peraturan Menteri Kesehatan Nomor 33 Tahun 2012 tentang Bahan Tambahan Pangan disebutkan bahwa bahan yang dilarang digunakan sebagai bahan tambahan pangan diantaranya adalah formalin dan boraks. Pada kenyataannya, di Kota Banda Aceh terdapat masalah dalam mewujudkan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Penulisan skripsi ini bertujuan untuk menjelaskan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks, faktor penyebab tidak berjalannya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks, dan upaya mengatasi hambatan perwujudan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Data yang diperlukan dalam tulisan ini adalah data sekunder dan data primer. Data sekunder diperoleh melalui penelitian kepustakaan dilakukan dengan cara membaca peraturan perundang-undangan, buku-buku, surat kabar dan bahan-bahan lain yang berkaitan dengan penelitian ini, dan data primer diperoleh dengan cara mewancarai responden dan informan.Hasil penelitian menunjukkan bahwa perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks di Kota Banda Aceh, belum berjalan sebagaimana yang telah diatur dalam Undang-Undang Nomor 18 Tahun 2012 dan Peraturan Menteri Kesehatan Nomor 33 Tahun 2012. Faktor penyebab tidak berjalannya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks yaitu kurangnya sosialisasi peraturan perundang-undangan, kurangnya pengawasan, kurangnya ketegasan dalam penerapan sanksi dan kurangnya laporan dari pihak masyarakat.Upaya mengatasi hambatan perwujudan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks yaitu penyuluhan hukum, pengawasan, peringatan dan pembinaan.Disarankan kepada instansi pemerintahan seperti Dinas Kesehatan dan BBPOM untuk menambah jumlah petugas serta mengalokasikan dana dalam melakukan pemeriksaan dan pengujian makanan jajanan sehingga terselenggaranya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Banda Ace

    Single-hit resolution measurement with MEG II drift chamber prototypes

    Get PDF
    Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles keeping the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the measurements performed on three different prototypes of the MEG II drift chamber aimed at determining the achievable single-hit resolution. The prototypes were operated with helium/isobutane gas mixtures and exposed to cosmic rays, electron beams and radioactive sources. Direct measurements of the single hit resolution performed with an external tracker returned a value of 110 Ό\mum, consistent with the values obtained with indirect measurements performed with the other prototypes.Comment: 18 pages, 18 figure

    Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets

    Get PDF
    Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.Comment: 14 pages, 16 figures. Updated to match published versio

    Selection of Single Top Events with the CMS Detector at LHC

    Get PDF
    The detection of single-top events with CMS is discussed. Two selections are proposed, aimed to measure single top production in the Standard Model t- and s-channel, respectively. The perspectives of the measurements for an integrated luminosity of 10 fb-1 are described. The results are based on detailed detector simulations, either based on GEANT4, or on faster techniques. The reconstruction procedures developed by the CMS Collaboration are utilized

    MEG Upgrade Proposal

    Full text link
    We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) \mu \to e \gamma, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the 6×10−146 \times 10^{-14} level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.Comment: A. M. Baldini and T. Mori Spokespersons. Research proposal submitted to the Paul Scherrer Institute Research Committee for Particle Physics at the Ring Cyclotron. 131 Page

    Measurement of the radiative decay of polarized muons in the MEG experiment

    Get PDF
    We studied the radiative muon decay ÎŒ+→e+ÎœÎœË‰Îł\mu^+ \to e^+\nu\bar{\nu}\gamma by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B(ÎŒ+→e+ÎœÎœË‰Îł\mu^+ \to e^+\nu\bar{\nu}\gamma) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_{\gamma} > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for ÎŒ+→e+Îł\mu^+ \to e^+\gamma process.Comment: 8 pages, 7 figures. Added an introduction to NLO calculation which was recently calculated. Published versio

    New constraint on the existence of the mu+-> e+ gamma decay

    Get PDF
    The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.Comment: 5 pages, 3 figures, a version accepted in Phys. Rev. Let

    The MEG detector for ÎŒ+→e+Îł{\mu}+\to e+{\gamma} decay search

    Get PDF
    The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous Ό+\mu^+ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.Comment: 59 pages, 90 figure
    • 

    corecore