14 research outputs found

    Is there a biological difference between trauma-related depression and PTSD? DST says 'NO'

    No full text
    The use of the low-dose dexamethasone suppression test (DST) as a potentially discriminative marker between post-traumatic stress disorder (PTSD) and depression is still under discussion. In order to compare the influence of these psychopathologies on the DST results, we examined suppression in war-traumatized subjects with one or both of these disorders, as well as in healthy controls. Based on our previous findings, we hypothesized that subjects with any disorder would exhibit higher dexamethasone suppression than healthy controls due to traumatic experiences. This study was a part of a broader project in which simultaneous psychological and biological investigations were carried out in hospital conditions on 399 mate participants: 57 with PTSD, 28 with depression, 76 with PTSD + depression, and 238 healthy controls. Cortisol was measured in blood samples taken at 0900 h before and after administering 0.5 mg of dexamethasone (at 2300 h). Group means standard deviation of cortisol suppression were: 79.4 +/- 18.5 in the PTSD group, 80.8 +/- 11.6 in the depression group, 77.5 +/- 24.6 in the group with PTSD+depression, and 66.8 +/- 34.6 in healthy controls. The first three groups suppressed significantly more than the fourth. When the number of traumas was introduced as a covariate, the differences disappeared. The hypothesis was confirmed: in respect to DST, the examined trauma-related psychopathologies showed the same pattern: hypersuppression, due to multiple traumatic experiences. (C) 2012 Elsevier Ltd. All rights reserved.European Commission [INCO-CT-2004-509213]; Ministry of Science, Serbia [179018, 41009

    Is there a biological difference between trauma-related depression and PTSD? DST says 'NO'

    No full text
    The use of the low-dose dexamethasone suppression test (DST) as a potentially discriminative marker between post-traumatic stress disorder (PTSD) and depression is still under discussion. In order to compare the influence of these psychopathologies on the DST results, we examined suppression in war-traumatized subjects with one or both of these disorders, as well as in healthy controls. Based on our previous findings, we hypothesized that subjects with any disorder would exhibit higher dexamethasone suppression than healthy controls due to traumatic experiences. This study was a part of a broader project in which simultaneous psychological and biological investigations were carried out in hospital conditions on 399 mate participants: 57 with PTSD, 28 with depression, 76 with PTSD + depression, and 238 healthy controls. Cortisol was measured in blood samples taken at 0900 h before and after administering 0.5 mg of dexamethasone (at 2300 h). Group means standard deviation of cortisol suppression were: 79.4 +/- 18.5 in the PTSD group, 80.8 +/- 11.6 in the depression group, 77.5 +/- 24.6 in the group with PTSD+depression, and 66.8 +/- 34.6 in healthy controls. The first three groups suppressed significantly more than the fourth. When the number of traumas was introduced as a covariate, the differences disappeared. The hypothesis was confirmed: in respect to DST, the examined trauma-related psychopathologies showed the same pattern: hypersuppression, due to multiple traumatic experiences. (C) 2012 Elsevier Ltd. All rights reserved.European Commission [INCO-CT-2004-509213]; Ministry of Science, Serbia [179018, 41009

    Hemometrijski pristup razvoju kolorimetrijske metode za procenu količine prehrambenih boja u proizvodima od mesa

    Get PDF
    The aim of this research was to develop a novel colorimetric method based on mathematical models, by multiple linear regression (MLR), from the CIE L*a*b* measurements and data of the HPLC determination of food colorants. Calibration set of 10 production batches of finely grinded cooked sausage with food colorants added was manufactured in industrial conditions as follows: one control batch and 9 products with various quantities of added food colorants: E120 (3.4, 7.5 and 12.5 mg/kg), E 124 (5.0, 15.0, 25.0 mg/kg) and E 129 (5.0, 15.0, 25.0 mg/kg). The estimation of the added food colorants was assessed by measuring L*, a*, b* parameters of cross-section. The quantification of food colorants was achieved by HPLC-PDA. Food colorants were extracted from meat products using Accelerated Solvent Extraction (ASE). Quantification of food colorants was achieved in the range from 1 to 100 mg / kg, and recovery values were from 76.15% to 107.04%, for E 120, from 97.61% to 101.03%, for E 124 and from 99.91% to 101.67%, for E 129. Correlation of the results obtained using HPLC and colorimetric measuring data was assessed by Multiple Linear Regression (MLR). The results from colorimetric and chromatographic determinations in four experimental batches (three batches with different quantities of food colorants and one control batch) were used for calibration. Coefficients of determination (R2) for linear models in experimental batches were 0.954, for E 124, 0.987, for E 120 and 0.993, for E 129. Correlation functions of food colorant quantities and corresponding L*a*b* values were established. The obtained mathematical models were tested for the estimation of the content of dyes in 21 samples of finely grinded cooked sausages purchased in retail stores. Food colorants were confirmed in 20 samples (95.24 %), and one sample (4.76 %) did not contain any of these compounds. Out of the positive samples, sixteen samples (80.00 %) contained E 120, while four samples (20.00 %) contained E 129. Food colorant E124 was not established in any of the analyzed samples. Colorimetric CIE L*a*b* method might be used during sensory evaluation of meat products for the assessment of the added food colorants.Cilj ovog rada je bio da se, merenjem vrednosti parametara boje preseka proizvoda od mesa u CIE (Commission Internationale de l'Eclairage, Međunarodna komisija za osvetljenje) L*a*b* prostoru (L* ā€“ svetloća, a* ā€“ udeo crvene boje i b* ā€“ udeo žute boje) ispita mogućnost procene sadržaja dodate prehrambene boje u proizvodima od mesa. Količina prehrambene boje u uzorcima od mesa određena je metodom visokoefikasne tečne hromatografije sa detekcijom na fotodiodnom sloju (HPLC-PDA), a međusobna zavisnost dobijenih vrednosti i kolorimetrijskih parametara ispitana je viÅ”estrukom linearnom regresijom (MLR). Kalibracioni set od 10 proizvodnih partija fino usitnjene barene kobasice, sa tri dodate boje, izrađen je u industrijskim uslovima, i to: kontrolni proizvod bez boje i 9 proizvoda sa različitim količinama dodatih boja E 120 (3,4; 7,5 i 12,5 mg/kg), E 124 (5, 15 i 25 mg/kg) i E 129 (5, 15 i 25 mg/kg). Postavljene su jednačine funkcije zavisnosti količine boje od L*, a* i b* vrednosti. Dobijeni matematički modeli su provereni i primenjeni za procenjivanje sadržaja boje u 21 uzorku fino usitnjenih barenih kobasica sa tržiÅ”ta. Utvrđeno je da se kolorimetrijskom CIE L*a*b* metodom mogu, u toku senzorskog ocenjivanja boje proizvoda, proceniti količine dodatih boja u proizvodima od mesa i da se ova metoda može primeniti kao komplementarna HPLC-PDA

    Effect of modified atmosphere and vacuum packaging on selected chemical parameters of rainbow trout (Oncorhynchus mykiss) and carp (Cyprinus carpio) cuts freshness

    Get PDF
    The purpose of food packing in modified atmosphere is to extend its sustainability by preventing both biochemical processes and growth of spoilage bacteria. Gases or their mixtures which are mostly used in the modified atmosphere food packing technology are carbon-dioxide (CO2), oxygen (O2) and nitrogen (N2). The aim of our research was to examine the influence of packaging in modified atmosphere and vacuum on the total volatile basic nitrogen (TVB-N) content and pH in muscle of rainbow trout (Oncorhynchus mykiss) and common carp (Cyprinus carpio), as well as to determine the most suitable gas mixtures for packing of these freshwater species. Three sample groups of trout and carp cuts were investigated. The first two groups were packaged in modified atmosphere with different gas ratios: 60%CO2+40%N2 (I group) and 40%CO2+60%N2 (II group), whereas the samples from third, control group, (III group) were vacuum packaged. During trials samples were stored in refrigerator at +3Ā°C. Determination of TVB-N and pH was performed on 1st, 7th and 14th day of storage. The obtained results indicate that the investigated mixtures of gases and vacuum as well had a significant influence on the values of TVB-N in trout and carp cuts samples. The lowest increase in TVB-N was established in trout and carp cuts samples from the group I, whereas the highest increase was established in samples from group III. Statistical significant difference (p < 0,001) between the average values of TVB-N for trout (I group: 18,17 Ā± 0,93; II group: 20,90 Ā± 0,81 and III group: 36,18 Ā± 2,65 mg N/100 g ) and carp cuts (I group: 26,74 Ā± 1,48; II group: 30,02 Ā± 0,31 and III group: 35,10 Ā± 1,75 mg N/100 g) was established on 14th day. The lowest pH value was established in samples packaged in modified atmosphere with 60% CO2 +40% N2 (I group). On 14th day of testing the obtained value was 6,15 Ā± 0,09 for trout and 5,94 Ā± 1,11 for carp samples. Increase in pH value in trout samples packed in vacuum was established during the whole period of investigation (p < 0,001), while in carp cuts samples packaged in vacuum the increase in pH value (p < 0,05) was established up to 7th day of testing. Based on the obtained results it can be concluded that gas mixture consisting of 60% CO2 and 40% N2 was the most suitable for packaging of fresh trout and carp cuts in terms of selected chemical parameters, such as TVB-N and pH. [Projekat Ministarstva nauke Republike Srbije, br. TR 31011 i br. TR 31075

    Chemometric approach in the development of the colorimetric method for the estimation of food colorants in meat products

    No full text
    The aim of this research was to develop a novel colorimetric method based on mathematical models, by multiple linear regression (MLR), from the CIE L*a*b* measurements and data of the HPLC determination of food colorants. Calibration set of 10 production batches of finely grinded cooked sausage with food colorants added was manufactured in industrial conditions as follows: one control batch and 9 products with various quantities of added food colorants: E120 (3.4, 7.5 and 12.5 mg/kg), E 124 (5.0, 15.0, 25.0 mg/kg) and E 129 (5.0, 15.0, 25.0 mg/kg). The estimation of the added food colorants was assessed by measuring L*, a*, b* parameters of cross-section. The quantification of food colorants was achieved by HPLC-PDA. Food colorants were extracted from meat products using Accelerated Solvent Extraction (ASE). Quantification of food colorants was achieved in the range from 1 to 100 mg / kg, and recovery values were from 76.15% to 107.04%, for E 120, from 97.61% to 101.03%, for E 124 and from 99.91% to 101.67%, for E 129. Correlation of the results obtained using HPLC and colorimetric measuring data was assessed by Multiple Linear Regression (MLR). The results from colorimetric and chromatographic determinations in four experimental batches (three batches with different quantities of food colorants and one control batch) were used for calibration. Coefficients of determination (R2) for linear models in experimental batches were 0.954, for E 124, 0.987, for E 120 and 0.993, for E 129. Correlation functions of food colorant quantities and corresponding L*a*b* values were established. The obtained mathematical models were tested for the estimation of the content of dyes in 21 samples of finely grinded cooked sausages purchased in retail stores. Food colorants were confirmed in 20 samples (95.24 %), and one sample (4.76 %) did not contain any of these compounds. Out of the positive samples, sixteen samples (80.00 %) contained E 120, while four samples (20.00 %) contained E 129. Food colorant E124 was not established in any of the analyzed samples. Colorimetric CIE L*a*b* method might be used during sensory evaluation of meat products for the assessment of the added food colorants
    corecore