1,960 research outputs found

    NASA/Pratt and Whitney experimental clean combustor program: Engine test results

    Get PDF
    A two-stage vorbix (vortex burning and mixing) combustor and associated fuel system components were successfully tested in an experimental JT9D engine at steady-state and transient operating conditions, using ASTM Jet-A fuel. Full-scale JT9D experimental engine tests were conducted in a phase three aircraft experimental clean combustor program. The low-pollution combustor, fuel system, and fuel control concepts were derived from phase one and phase two programs in which several combustor concepts were evaluated, refined, and optimized in a component test rig. Significant pollution reductions were achieved with the combustor which meets the performance, operating, and installation requirements of the engine

    Experimental clean combustor program, phase 3

    Get PDF
    A two-stage vortex burning and mixing combustor and associated fuel system components were successfully tested at steady state and transient operating conditions. The combustor exceeded the program goals for all three emissions species, with oxides of nitrogen 10 percent below the goal, carbon monoxide 26 percent below the goal, and total unburned hydrocarbons 75 percent below the goal. Relative to the JT9D-7 combustor, the oxides of nitrogen were reduced by 58 percent, carbon monoxide emissions were reduced by 69 percent, and total unburned hydrocarbons were reduced by 9 percent. The combustor efficiency and exit temperature profiles were comparable to those of production combustor. Acceleration and starting characteristics were deficient relative to the production engine

    An assessment of the use of antimisting fuel in turbofan engines

    Get PDF
    An evaluation was made on the effects of using antimisting kerosene (AMK) on the performance of the components from the fuel system and the combustor of current in service JT8D aircraft engines. The objectives were to identify if there were any problems associated with using antimisting kerosene and to determine the extent of shearing or degradation required to allow the engine components to achieve satisfactory operation. The program consisted of a literature survey and a test program which evaluated the antimisting kerosene fuel in laboratory and bench component testing, and assessed the performance of the combustor in a high pressure facility and in an altitude relight/cold ignition facility

    An assessment of the use of antimisting fuel in turbofan engines

    Get PDF
    The effects of antimisting kerosene on the performance of the components from the fuel system and the combustor of a JT8D aircraft engine were evaluated. The problems associated with antimisting kerosene were identified and the extent of shearing or degradation required to allow the engine components to achieve satisfactory operation were determined. The performance of the combustor was assessed in a high pressure facility and in an altitude relight/cold ignition facility. The performance of the fuel pump and control system was evaluated in an open loop simulation

    Evaluation of Federal Aviation Administration ion engine exhaust sampling rake

    Get PDF
    A FAA exhaust emissions rake was tested in the Experimental Clean Combustor Program, Phase 3 to permit comparison of the values of gaseous emissions and smoke measured by the FAA rake with those measured with the NASA Pratt and Whitney Aircraft (P and WA) rake used in the Phase 3 Experimental Clean Combustor Program and with station seven probes. The results showed that the levels of CO, THC, NOx and smoke measured by the FAA and NASA/P and WA rakes agree well at high power, but that CO emissions measured by the FAA rake were approximately 10 percent higher than those measured by the NASA/P and WA rake at low power

    Secure self-calibrating quantum random bit generator

    Get PDF
    Random bit generators (RBGs) are key components of a variety of information processing applications ranging from simulations to cryptography. In particular, cryptographic systems require "strong" RBGs that produce high-entropy bit sequences, but traditional software pseudo-RBGs have very low entropy content and therefore are relatively weak for cryptography. Hardware RBGs yield entropy from chaotic or quantum physical systems and therefore are expected to exhibit high entropy, but in current implementations their exact entropy content is unknown. Here we report a quantum random bit generator (QRBG) that harvests entropy by measuring single-photon and entangled two-photon polarization states. We introduce and implement a quantum tomographic method to measure a lower bound on the "min-entropy" of the system, and we employ this value to distill a truly random bit sequence. This approach is secure: even if an attacker takes control of the source of optical states, a secure random sequence can be distilled.Comment: 5 pages, 2 figure

    Metronomic Chemotherapy with Vinorelbine Produces Clinical Benefit and Low Toxicity in Frail Elderly Patients Affected by Advanced Non-Small Cell Lung Cancer

    Get PDF
    Lung cancer is the leading cause of death worldwide. The treatment choice for advanced stage of lung cancer may depend on histotype, performance status (PS), age, and comorbidities. In the present study, we focused on the effect of metronomic vinorelbine treatment in elderly patients with advanced unresectable non-small cell lung cancer (NSCLC). Methods. From January 2016 to December 2016, 44 patients affected by non-small cell lung cancer referred to our oncology day hospital were progressively analyzed. The patients were treated with oral vinorelbine 30 mg x 3/wk or 40 mg x 3/wk meaning one day on and one day off. The patients were older than 60, stage IIIB or IV, ECOG PS ≥ 1, and have at least one important comorbidity (renal, hepatic, or cardiovascular disease). The schedule was based on ECOG-PS and comorbidities. The primary endpoint was progression-free survival (PFS). PFS was used to compare patients based on different scheduled dosage (30 or 40 mg x3/weekly) and age (more or less than 75 years old) as exploratory analysis. We also evaluated as secondary endpoint toxicity according to Common Toxicity Criteria Version 2.0. Results. Vinorelbine showed a good safety profile at different doses taken orally and was effective in controlling cancer progression. The median overall survival (OS) was 12 months. The disease control rate (DCR) achieved 63%. The median PFS was 9 months. A significant difference in PFS was detected comparing patients aged below with those over 75, and the HR value was 0.72 (p<0.05). Not significant was the difference between groups with different schedules. Conclusions. This study confirmed the safety profile of metronomic vinorelbine and its applicability for patients unfit for standard chemotherapies and adds the possibility of considering this type of schedule not only for very elderly patients

    Additive manufacturing of PLA to mimic the thrust force of mandibular bone during drilling

    Get PDF
    Edentulism is a condition that results in the partial or total loss of teeth. It may lead to problems during chewing and be a cause of self-isolation and low self-esteem. Edentulism can be resolved both with removable prostheses (dentures) and fixed implants, with the latter being more efficient. The installation of a fixed implant involves a real surgical operation in which the jaw/mandibular bone is drilled through a special drill. One of the main cautions the surgeon must have during the operation is not to sever the nerves during the drilling. Given the composition of the bone is different in each person, the drilling thrust force is variable and controlling its movement can sometimes be complicated. Therefore, being able to test the operation on a dummy may reduce the number of errors. Additive manufacturing with its high degree of customization and ability to produce objects with almost no geometrical limitations could provide the required features to realize the dummy. In this work, the drilling properties of samples made in PLA through Fused Filament Fabrication (FFF) were studied. The samples were designed to mimic the composition of the bone. Specifically, a thin, hard, and denser outer layer and a 25% internal filling were adopted. The samples were drilled with a dental drill properly connected to a collaborative robot
    • …
    corecore