281 research outputs found

    Favorable Trend of Implantable Cardioverter-Defibrillator Service Life in a Large Single-Nation Population: Insights From 10-Year Analysis of the Italian Implantable Cardioverter-Defibrillator Registry

    Get PDF
    Background: Implantable cardioverter-defibrillators (ICDs) are widely employed for the prevention of sudden cardiac death. Despite technological improvements, patients often need to undergo generator replacement, which entails the risk of periprocedural complications. Our aim was to estimate the service life of ICDs over a 10-year interval and to assess the main causes of replacement on the basis of data from the National ICD Registry of the Italian Society of Arrhythmology and Cardiac Pacing (AIAC). Methods and Results: The registry includes data from over 400 hospitals in Italy. We included all patients who underwent device replacement from calendar years 2007 to 2016. The median service life of the ICDs and its trend over the years was estimated across the 3 types of devices (single-chamber, dual-chamber, cardiac resynchronization therapy defibrillator) and the indication to implantation. The causes of replacement were also analyzed. We included 29 158 records from 27 676 patients (80.9% men; mean age at device replacement 65.8±12.0 years). The median service life was 57.3 months (interquartile range 27.8 months). Over the years, service life showed an increasing trend. The majority of patients underwent elective replacement because of battery end of life, and over the years there was a significant reduction of replacement for recalls, erosion/infections, and cardiac resynchronization therapy upgrading. Conclusions: Our data from a large single-nation population showed that the trend of ICD service life, independently from ICD type, indication, and settings, significantly improved over time. Moreover, there was a striking reduction of interventions for upgrading and infection/erosion. This favorable trend has important clinical, organizational, and financial implications

    A global analysis of implants and replacements of pacemakers and cardioverter-defibrillators before, during, and after the COVID-19 pandemic in Italy

    Get PDF
    At the beginning of the COVID-19 emergency, non-urgent surgical procedures had to be deferred, but also emergencies were reduced. To assess the global trend of pacemaker (PM) and implantable cardiac-defibrillator (ICD) procedures performed in Italy before, during, and after the first COVID-19 emergency, all the Italian hospital discharge records related to PM/ICD procedures performed between 2012 and 2021, sent to the National Institute of Health, were reviewed. Compared to 2019, in 2020, there was a reduction of first PM implants (52,216 to 43,962, −16%; p < 0.01), but not replacements (16,591 to 17,331, + 4%; p = 0.16). In particular, in April 2020, there was a drop of first implants (− 53,4% vs the average value of April 2018 and April 2019; p < 0.01), while the reduction of replacements was less evident (−32.6%; p = NS). In 2021, PM procedures increased to values similar to the pre-pandemic period. A reduction of ICD procedures was observed in 2020 (22,355, −7% toward 2019), mainly in April 2020 (− 46% vs April 2018/April 2019; p = 0.03). In 2021, the rate of ICD procedures increased (+ 14% toward 2020). A non-significant reduction of “urgent” procedures (complete atrioventricular block for PM and ventricular fibrillation for ICD), even in April 2020, was observed. In 2020, there was a reduction of first PM implants and ICDs, offset by increased activity in 2021. No decrease in PM replacements was observed, and the drop in “urgent” PM and ICD procedures was not statistically significant

    Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry

    Get PDF
    AimsTo analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients.Methods and resultsPatients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy.ConclusionIn 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available
    corecore