284 research outputs found

    Dynamic behaviour of nutrients

    Get PDF

    Paracrine IL-2 Is Required for Optimal Type 2 Effector Cytokine Production

    Get PDF
    IL-2 is a pleiotropic cytokine that promotes the differentiation of Th cell subsets, including Th1, Th2, and Th9 cells, but it impairs the development of Th17 and T follicular helper cells. Although IL-2 is produced by all polarized Th subsets to some level, how it impacts cytokine production when effector T cells are restimulated is unknown. We show in this article that Golgi transport inhibitors (GTIs) blocked IL-9 production. Mechanistically, GTIs blocked secretion of IL-2 that normally feeds back in a paracrine manner to promote STAT5 activation and IL-9 production. IL-2 feedback had no effect on Th1- or Th17-signature cytokine production, but it promoted Th2- and Th9-associated cytokine expression. These data suggest that the use of GTIs results in an underestimation of the presence of type 2 cytokine-secreting cells and highlight IL-2 as a critical component in optimal cytokine production by Th2 and Th9 cells in vitro and in vivo

    The Microchannel X-ray Telescope on Board the SVOM Satellite

    Full text link
    We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1{\deg}) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type developed for the seven eROSITA telescopes. MXT is a compact and light (<35 kg) telescope with a 1 m focal length, and it will provide an effective area of about 45 cmsq on axis at 1 keV. The MXT PSF is expected to be better than 4.2 arc min (FWHM) ensuring a localization accuracy of the afterglows of the SVOM GRBs to better than 1 arc min (90\% c.l. with no systematics) provided MXT data are collected within 5 minutes after the trigger. The MXT sensitivity will be adequate to detect the afterglows for almost all the SVOM GRBs as well as to perform observations of non-GRB astrophysical objects. These performances are fully adapted to the SVOM science goals, and prove that small and light telescopes can be used for future small X-ray missions.Comment: 6 pages, 6 figures, proceedings of the conference "Swift: 10 years of Discovery", Rome, December 2-5, 2014. To be published by Po

    Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer

    Get PDF
    Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical process. This is why most of the projects for the next generation of space missions covering the tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The hard X-ray imaging spectrometer module, developed in CEA with the generic name of Caliste module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed to linearly polarized beams at the European Synchrotron Radiation Facility. These results, obtained at 200-300 keV, demonstrate their capability to give an accurate determination of the polarization parameters (polarization angle and fraction) of the incoming beam. Applying a selection to our data set, equivalent to select 90 degrees Compton scattered interactions in the detector plane, we find a modulation factor Q of 0.78. The polarization angle and fraction are derived with accuracies of approximately 1 degree and 5%. The modulation factor remains larger than 0.4 when essentially no selection is made at all on the data. These results prove that the Caliste-256 modules have performances allowing them to be excellent candidates as detectors with polarimetric capabilities, in particular for future space missions.Comment: 17 pages, 14 figures, 2 tables in Experimental Astronomy, 201

    Spectral performance of the Microchannel X-ray Telescope on board the SVOM mission

    Full text link
    The Microchannel X-ray Telescope (MXT) is an innovative compact X-ray instrument on board the SVOM astronomical mission dedicated to the study of transient phenomena such as gamma-ray bursts. During 3 weeks, we have tested the MXT flight model at the Panter X-ray test facility under the nominal temperature and vacuum conditions that MXT will undergo in-flight. We collected data at series of characteristic energies probing the entire MXT energy range, from 0.28 keV up to 9 keV, for multiple source positions with the center of the point spread function (PSF) inside and outside the detector field of view (FOV). We stacked the data of the positions with the PSF outside the FOV to obtain a uniformly illuminated matrix and reduced all data sets using a dedicated pipeline. We determined the best spectral performance of MXT using an optimized data processing, especially for the energy calibration and the charge sharing effect induced by the pixel low energy thresholding. Our results demonstrate that MXT is compliant with the instrument requirement regarding the energy resolution (<80 eV at 1.5 keV), the low and high energy threshold, and the accuracy of the energy calibration (±\pm20 eV). We also determined the charge transfer inefficiency (~10510^{-5}) of the detector and modeled its evolution with energy prior to the irradiation that MXT will undergo during its in-orbit lifetime. Finally, we measured the relation of the energy resolution as function of the photon energy. We determined an equivalent noise charge of 4.9 ±\pm 0.2 e- rms for the MXT detection chain and a Fano factor of 0.131 ±\pm 0.003 in silicon at 208 K, in agreement with previous works. This campaign confirmed the promising scientific performance that MXT will be able to deliver during the mission lifetime.Comment: 20 pages, 10 figures, accepted for publication in Experimental Astronom

    Atomic layer deposition of high-k dielectric layers on Ge and III-V MOS channels

    Get PDF
    Ge and III-V semiconductors are potential high performance channel materials for future CMOS devices. In this work, we have studied At. Layer Deposition (ALD) of high-k dielec. layers on Ge and GaAs substrates. We focus at the effect of the oxidant (H2O, O3, O2, O2 plasma) during gate stack formation. GeO2, obtained by Ge oxidn. in O2 or O3, is a promising passivation layer. The germanium oxide thickness can be scaled down below 1 nm, but such thin layers contain Ge in oxidn. states lower than 4+. Still, elec. results indicate that small amts. of Ge in oxidn. states lower than 4+ are not detrimental for device performance. Partial intermixing was obsd. for high-k dielec. and GeO2 or GaAsOx, suggesting possible correlations in the ALD growth mechanisms on Ge and GaAs substrates. [on SciFinder (R)

    The COSPIX mission: focusing on the energetic and obscured Universe

    Full text link
    Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of its call for selection of the M3 mission. In addition, COSPIX, will also provide key measurements on the non thermal Universe, particularly in relation to the question of the acceleration of particles, as well as on many other fundamental questions as for example the energetic particle content of clusters of galaxies. COSPIX is proposed as an observatory operating from 0.3 to more than 100 keV. The payload features a single long focal length focusing telescope offering an effective area close to ten times larger than any scheduled focusing mission at 30 keV, an angular resolution better than 20 arcseconds in hard X-rays, and polarimetric capabilities within the same focal plane instrumentation. In this paper, we describe the science objectives of the mission, its baseline design, and its performances, as proposed to ESA.Comment: 7 pages, accepted for publication in Proceedings of Science, for the 25th Texas Symposium on Relativistic Astrophysics (eds. F. Rieger &amp; C. van Eldik), PoS(Texas 2010)25

    The Scientific Performance of the Microchannel X-ray Telescope on board the SVOM Mission

    Full text link
    The Microchannel X-ray Telescope (MXT) will be the first focusing X-ray telescope based on a "Lobster-Eye" optical design to be flown on Sino-French mission SVOM. SVOM will be dedicated to the study of Gamma-Ray Bursts and more generally time-domain astrophysics. The MXT telescope is a compact (focal length ~ 1.15 m) and light (< 42 kg) instrument, sensitive in the 0.2--10 keV energy range. It is composed of an optical system, based on micro-pore optics (MPOs) of 40 micron pore size, coupled to a low-noise pnCDD X-ray detector. In this paper we describe the expected scientific performance of the MXT telescope, based on the End-to-End calibration campaign performed in fall 2021, before the integration of the SVOM payload on the satellite.Comment: 22 pages, 12 figures, accepted for publication in Experimental Astronom

    The Effects Combining Cryocompression Therapy following an Acute Bout of Resistance Exercise on Performance and Recovery

    Get PDF
    Compression and cold therapy used separately have shown to reduce negative effects of tissue damage. The combining compression and cold therapy (cryocompression) as a single recovery modality has yet to be fully examined. To examine the effects of cryocompression on recovery following a bout of heavy resistance exercise, recreationally resistance trained men (n =16) were recruited, matched, and randomly assigned to either a cryocompression group (CRC) or control group (CON). Testing was performed before and then immediately after exercise, 60 minutes, 24 hours, and 48 hours after a heavy resistance exercise workout (barbell back squats for 4 sets of 6 reps at 80% 1RM, 90 sec rest between sets, stiff legged deadlifts for 4 sets of 8 reps at 1.0 X body mass with 60 sec rest between sets, 4 sets of 10 eccentric Nordic hamstring curls, 45 sec rest between sets). The CRC group used the CRC system for 20-mins of cryocompression treatment immediately after exercise, 24 hours, and 48 hours after exercise. CON sat quietly for 20-mins at the same time points. Muscle damage [creatine kinase], soreness (visual analog scale, 0-100), pain (McGill Pain Q, 0-5), fatigue, sleep quality, and jump power were significantly (p \u3c 0.05) improved for CRC compared to CON at 24 and 48 hours after exercise. Pain was also significantly lower for CRC compared to CON at 60-mins post exercise. These findings show that cryocompression can enhance recovery and performance following a heavy resistance exercise workout
    corecore