284 research outputs found

    Understanding of research, genetics and genetic research in a rapid ethical assessment in north west Cameroon

    Get PDF
    BACKGROUND There is limited assessment of whether research participants in low-income settings are afforded a full understanding of the meaning of medical research. There may also be particular issues with the understanding of genetic research. We used a rapid ethical assessment methodology to explore perceptions surrounding the meaning of research, genetics and genetic research in north west Cameroon. METHODS Eleven focus group discussions (including 107 adults) and 72 in-depth interviews were conducted with various stakeholders in two health districts in north west Cameroon between February and April 2012. RESULTS Most participants appreciated the role of research in generating knowledge and identified a difference between research and healthcare but gave varied explanations as to this difference. Most participants' understanding of genetics was limited to concepts of hereditary, with potential benefits limited to the level of the individual or family. Explanations based on supernatural beliefs were identified as a special issue but participants tended not to identify any other special risks with genetic research. CONCLUSION We demonstrated a variable level of understanding of research, genetics and genetic research, with implications for those carrying out genetic research in this and other low resource settings. Our study highlights the utility of rapid ethical assessment prior to complex or sensitive research

    Creating an experimental testbed for information-theoretic analysis of architectures for x-ray anomaly detection

    Full text link
    Anomaly detection requires a system that can reliably convert measurements of an object into knowledge about that object. Previously, we have shown that an information-theoretic approach to the design and analysis of such systems provides insight into system performance as it pertains to architectural variations in source fluence, view number/angle, spectral resolution, and spatial resolution.(1) However, this work was based on simulated measurements which, in turn, relied on assumptions made in our simulation models and virtual objects. In this work, we describe our experimental testbed capable of making transmission x-ray measurements. The spatial, spectral, and temporal resolution is sufficient to validate aspects of the simulation-based framework, including the forward models, bag packing techniques, and performance analysis. In our experimental CT system, designed baggage is placed on a rotation stage located between a tungsten-anode source and a spectroscopic detector array. The setup is able to measure a full 360 rotation with 18,000 views, each of which defines a 10 ms exposure of 1,536 detector elements, each with 64 spectral channels. Measurements were made of 1,000 bags that comprise 100 clutter instantiations each with 10 different target materials. Moreover, we develop a systematic way to generate bags representative of our desired clutter and target distributions. This gives the dataset a statistical significance valuable in future investigations.US Department of Homeland Security through the Advanced X-Ray Material Discrimination ProgramThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Countercurrent chromatography in analytical chemistry (IUPAC technical report)

    Get PDF
    © 2009 IUPACCountercurrent chromatography (CCC) is a generic term covering all forms of liquid-liquid chromatography that use a support-free liquid stationary phase held in place by a simple centrifugal or complex centrifugal force field. Biphasic liquid systems are used with one liquid phase being the stationary phase and the other being the mobile phase. Although initiated almost 30 years ago, CCC lacked reliable columns. This is changing now, and the newly designed centrifuges appearing on the market make excellent CCC columns. This review focuses on the advantages of a liquid stationary phase and addresses the chromatographic theory of CCC. The main difference with classical liquid chromatography (LC) is the variable volume of the stationary phase. There are mainly two different ways to obtain a liquid stationary phase using centrifugal forces, the hydrostatic way and the hydrodynamic way. These two kinds of CCC columns are described and compared. The reported applications of CCC in analytical chemistry and comparison with other separation and enrichment methods show that the technique can be successfully used in the analysis of plants and other natural products, for the separation of biochemicals and pharmaceuticals, for the separation of alkaloids from medical herbs, in food analysis, etc. On the basis of the studies of the last two decades, recommendations are also given for the application of CCC in trace inorganic analysis and in radioanalytical chemistry

    ESTIMATION OF PRIMIDONE IN COMMERCIAL DOSAGE FORMS USING A SIMPLE AND CONVENIENT HPLC METHOD

    Get PDF
    ABSTRACT A simple fast and precise reverse phase high performance liquid chromatographic method has been developed for the determination of Primidone Tablets. A symmetry (5µ, 150 x 4 .6mm column) in isocratic mode with methanol: Water (50:50) as mobile phase. The Flow rate is1.0ml/min and effluent is monitored at 210nm

    Bilateral macular hole formation secondary to sclopetaria caused by shockwaves transmitted by a posterior vector: case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sclopetaria is a rare ophthalmic finding in trauma</p> <p>Case Presentation</p> <p>This is a report of a patient who developed macular holes from sclopetaria induced by indirect trauma. A 22-year-old male, suffered a gunshot wound that passed behind his eyes, resulting in bilateral macular hole formation</p> <p>Conclusion</p> <p>To our knowledge, this is the first reported case in which trauma posterior to the globes caused bilateral macular hole formation</p

    Safety and efficacy of sonothrombolysis for acute ischaemic stroke: a multicentre, double-blind, phase 3, randomised controlled trial

    Get PDF
    Background: Pulsed-wave ultrasound increases the exposure of an intracranial thrombus to alteplase (recombinant tissue plasminogen activator), potentially facilitating early reperfusion. We aimed to ascertain if a novel operator-independent transcranial ultrasound device delivering low-power high-frequency ultrasound could improve functional outcome in patients treated with alteplase after acute ischaemic stroke. Methods: We did a multicentre, double-blind, phase 3, randomised controlled trial (CLOTBUST-ER) at 76 medical centres in 14 countries. We included patients with acute ischaemic stroke (National Institutes of Health Stroke Scale score ≥10) who received intravenous thrombolysis (alteplase bolus) within 3 h of symptom onset in North America and within 4·5 h of symptom onset in all other countries. Participants were randomly allocated (1:1) via an interactive web response system to either active ultrasound (2 MHz pulsed-wave ultrasound for 120 min [sonothrombolysis]; intervention group) or sham ultrasound (control group). Ultrasound was delivered using an operator-independent device, which had to be activated within 30 min of the alteplase bolus. Participants, investigators, and those assessing outcomes were unaware of group assignments. The primary outcome was improvement in the modified Rankin Scale score at 90 days in patients enrolled within 3 h of symptom onset, assessed in the intention-to-treat population as a common odds ratio (cOR) using ordinal logistic regression shift analysis. This trial is registered with ClinicalTrials.gov, number NCT01098981. The trial was stopped early by the funder after the second interim analysis because of futility. Findings: Between August, 2013, and April, 2015, 335 patients were randomly allocated to the intervention group and 341 patients to the control group. Compared with the control group, the adjusted cOR for an improvement in modified Rankin Scale score at 90 days in the intervention group was 1·05 (95% CI 0·77–1·45; p=0·74). 51 (16%) of 317 patients in the intervention group and 44 (13%) of 329 patients in the control group died (unadjusted OR 1·24, 95% CI 0·80–1·92; p=0·37) and 83 (26%) and 79 (24%), respectively, had serious adverse events (1·12, 0·79–1·60; p=0·53). Interpretation: Sonothrombolysis delivered by an operator-independent device to patients treated with alteplase after acute ischaemic stroke was feasible and most likely safe, but no clinical benefit was seen at 90 days. Sonothrombolysis could be further investigated either in randomised trials undertaken in stroke centres that are dependent on patient transfer for endovascular reperfusion therapies or in countries where these treatments cannot yet be offered as the standard of care

    Endovascular equipoise shift in a phase III randomized clinical trial of sonothrombolysis for acute ischemic stroke

    Get PDF
    Background: Results of our recently published phase III randomized clinical trial of ultrasound-enhanced thrombolysis (sonothrombolysis) using an operator-independent, high frequency ultrasound device revealed heterogeneity of patient recruitment among centers. Methods: We performed a post hoc analysis after excluding subjects that were recruited at centers reporting a decline in the balance of randomization between sonothrombolysis and concurrent endovascular trials. Results: From a total of 676 participants randomized in the CLOTBUST-ER trial we identified 52 patients from 7 centers with perceived equipoise shift in favor of endovascular treatment. Post hoc sensitivity analysis in the intention-to-treat population adjusted for age, National Institutes of Health Scale score at baseline, time from stroke onset to tPA bolus and baseline serum glucose showed a significant (p &lt; 0.01) interaction of perceived endovascular equipoise shift on the association between sonothrombolysis and 3 month functional outcome [adjusted common odds ratio (cOR) in centers with perceived endovascular equipoise shift: 0.22, 95% CI 0.06–0.75; p = 0.02; adjusted cOR for centers without endovascular equipoise shift: 1.20, 95% CI 0.89–1.62; p = 0.24)]. After excluding centers with perceived endovascular equipoise shift, patients randomized to sonothrombolysis had higher odds of 3 month functional independence (mRS scores 0–2) compared with patients treated with tPA only (adjusted OR: 1.53; 95% CI 1.01–2.31; p = 0.04). Conclusion: Our experience in CLOTBUST-ER indicates that increasing implementation of endovascular therapies across major academic stroke centers raises significant challenges for clinical trials aiming to test noninterventional or adjuvant reperfusion strategies
    corecore