848 research outputs found

    Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries

    Get PDF
    The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.Comment: 22 pages, 8 figures, 1 table, (minor corrections and changes made to text and figures in version 2

    Experimental demonstration of coupled optical springs

    Get PDF
    Optical rigidity will play an important role in improving the sensitivity of future generations of gravitational wave (GW) interferometers, which employ high laser power in order to reach and exceed the standard quantum limit. Several experiments have demonstrated the combined effect of two optical springs on a single system for very low-weight mirror masses or membranes. In this paper we investigate the complex interactions between multiple optical springs and the surrounding apparatus in a system of comparable dynamics to a large-scale GW detector. Using three 100 g mirrors to form a coupled cavity system capable of sustaining two or more optical springs, we demonstrate a number of different regimes of opto-mechanical rigidity and measurement techniques. Our measurements reveal couplings between each optical spring and the control loops that can affect both the achievable increase in sensitivity and the stability of the system. Hence this work establishes a better understanding of the realisation of these techniques and paves the way to their application in future GW observatories, such as upgrades to Advanced LIGO

    The clinical and cost-effectiveness of a Victim Improvement Package (VIP) for the reduction of chronic symptoms of depression or anxiety in older victims of common crime (the VIP trial): study protocol for a randomised controlled trial.

    Get PDF
    BACKGROUND: Older people are vulnerable to sustained high levels of psychosocial distress following a crime. A cognitive behavioural therapy (CBT)-informed psychological therapy, the Victim Improvement Package (VIP) may aid recovery. The VIP trial aims to test the clinical and cost-effectiveness of the VIP for alleviating depressive and anxiety symptoms in older victims of crime. METHODS/DESIGN: People aged 65 years or more who report being a victim of crime will be screened by Metropolitan Police Service Safer Neighbourhood Teams within a month of the crime for distress using the Patient Health Questionnaire-2 and the Generalised Anxiety Disorder-2. Those who screen positive will be signposted to their GP for assistance, and re-screened at 3 months. Participants who screen positive for depression and/or anxiety at re-screening are randomised to a CBT informed VIP added to treatment as usual (TAU) compared to TAU alone. The intervention consists of 10 individual 1-h sessions, delivered weekly by therapists from the mental health charity Mind. The primary outcome measure is the Beck Depression Inventory-II (BDI-II) and the Beck Anxiety Inventory (BAI), used as a composite measure, assessed at 6 months after the crime (post therapy) with a 9-month post-crime follow-up. Secondary outcome measures include the EQ-5D, and a modified Client Service Receipt Inventory. A total of 226 participants will be randomised VIP:TAU with a ratio 1:1, in order to detect a standardised difference of at least 0.5 between groups, using a mixed-effects linear-regression model with 90% power and a 5% significance level (adjusting for therapist clustering and potential drop-out). A cost-effectiveness analysis will incorporate intervention costs to compare overall health care costs and quality of life years between treatment arms. An embedded study will examine the impact of past trauma and engagement in safety behaviours and distress on the main outcomes. DISCUSSION: This trial should provide data on the clinical and cost-effectiveness of a CBT-informed psychological therapy for older victims of crime with anxiety and/or depressive symptoms and should demonstrate a model of integrated cross-agency working. Our findings should provide evidence for policy-makers, commissioners and clinicians responding to the needs of older victims of crime. TRIAL REGISTRATION: International Standard Randomised Controlled Trials Number, ID: ISRCTN16929670. Registered on 3 August 2016

    The failure of suicide prevention in primary care: family and GP perspectives - a qualitative study

    Get PDF
    Background Although Primary care is crucial for suicide prevention, clinicians tend to report completed suicides in their care as non-preventable. We aimed to examine systemic inadequacies in suicide prevention from the perspectives of bereaved family members and GPs.Methods Qualitative study of 72 relatives or close friends bereaved by suicide and 19 General Practitioners who have experienced the suicide of patients.Results Relatives highlight failures in detecting symptoms and behavioral changes and the inability of GPs to understand the needs of patients and their social contexts. A perceived overreliance on anti-depressant treatment is a major source of criticism by family members. GPs tend to lack confidence in the recognition and management of suicidal patients, and report structural inadequacies in service provision.Conclusions Mental health and primary care services must find innovative and ethical ways to involve families in the decision-making process for patients at risk of suicide

    Agitation near the end of life with dementia: An ethnographic study of care

    Get PDF
    Background and objectives Agitation is common in people living with dementia especially at the end of life. We examined how staff interpreted agitation behavior in people with dementia nearing end of life, how this may influence their responses and its impact on the quality of care. Research design Ethnographic study. Structured and semi-structured non-participant observations (referred to subsequently in this paper as “structured observations”) of people living with dementia nearing the end of life in hospital and care homes (south-east England) and in-depth interviews with staff, conducted August 2015-March 2017. Methods Three data sources: 1) detailed field notes, 2) observations using a structured tool and checklist for behaviors classed as agitation and staff and institutional responses, 3) staff semi-structured qualitative interviews. We calculated the time participants were agitated and described staff responses. Data sources were analyzed separately, developed continuously and relationally during the study and synthesized where appropriate. Results We identified two main ‘ideal types’ of staff explanatory models for agitation: In the first, staff attribute agitated behaviors to the person’s “moral judgement”, making them prone to rejecting or punitive responses. In the second staff adopt a more “needs-based” approach in which agitation behaviors are regarded as meaningful and managed with proactive and investigative approaches. These different approaches appear to have significant consequences for the timing, frequency and quality of staff response. While these models may overlap they tend to reflect distinct organizational resources and values. Conclusions Care worker knowledge about agitation is not enough, and staff need organizational support to care better for people living with dementia towards end of life. Positional theory may help to explain much of the cultural-structural context that produces staff disengagement from people with dementia, offering insights on how agitation behavior is reframed by some staff as dangerous. Such behavior may be associated with low-resource institutions with minimal staff training where the personhood of staff may be neglected

    Design of a speed meter interferometer proof-of-principle experiment

    Get PDF
    The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.Comment: Revised version: 16 pages, 6 figure

    An Online Survey of the Dietary Practices of Saudi Students in the UK: A Quantitative Study

    Get PDF
    There has been an abundance of research on the dietary practices of international university students in the United Kingdom (UK), as they comprise a significant proportion of the country’s undergraduate population. However, there is a paucity in the literature with regard to the dietary practices, or other health behaviours, of Saudi students studying in the UK. Therefore, this empirical study sought to provide new insights to address this gap. This study contribution to investigate the dietary practices of Saudi students in the UK. The data was collected from a sample of 212 university students and encompassed an age range from 18 to 31+ years. A quantitative methodology was adopted in the form of an exploratory survey questionnaire. The sample was recruited through voluntary and snowball sampling techniques. Questionnaire data was analysed using Microsoft Excel and SPSS for Windows, version 26. The results demonstrated that various intrapersonal, interpersonal, and environmental factors play a significant role in developing eating behaviours and dietary choices. Some favourable changes in dietary practices were observed among Saudi students in the UK as opposed to Saudi Arabia, including a higher intake of fruit and vegetables, along with a lower intake of soft drinks, sugary and fatty foods. However, there was a notable reduction in consumption of all types of meat and fish as well as the total number of daily meals. Additionally, around a third of participants regularly consumed ready-to-eat food and takeaways 2-6 times a week. Interventions should therefore consider individual, societal and environmental factors

    Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors

    Get PDF
    The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.Comment: 7 pages, 5 figure

    Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors

    Get PDF
    With the recent detection of Gravitational waves (GW), marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise (QN) limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum noise limited sensitivity is independent of the actual interferometer configuration, e.g. Michelson and Sagnac interferometers are effected in the same way. We show that misalignment of the output ports of the interferometer (output misalignment) only effects the high frequency part of the quantum noise limited sensitivity (detection noise). However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise (back action noise) by the same amount and hence the quantum noise limited sensitivity is not negatively effected in that frequency range. We show that the misalignment of laser into the interferometer (input misalignment) produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof of concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment
    • 

    corecore