297 research outputs found

    Quality control of injection molded eyewear by non-contact deflectometry

    Get PDF
    Occupational eye wear such as safety spectacles are manufactured by injection molding techniques. Testing of the assembled safety spectacle lenses in transmission is state of the art, but there is a lack of surface measurement systems for occupational safety lenses. The purpose of this work was to validate a deflectometric setup for topography measurement, detection of defects and visualization of the polishing quality, e.g. casting indentations or impressions, for the production process of safety spectacles. The setup is based on a customized stereo phase measuring deflectometer (PMD), equipped with 3 cameras with f’1,2 = 16 mm and f’3 = 8.5 mm and a specified measurement uncertainty of ± 3 μm. Sixteen plastic lenses and 8 corresponding injection molds from 4 parallel cavities were used for validation of the deflectometer. For comparison an interferometric method and a reference standard (< λ/10 super polished) was used. The accuracy and bias with a spherical safety spectacle sample was below 1 μm, according to DIN ISO 5725-2.2002-12. The repeatability was 2.1 μm and 35.7 μm for a blind radius fit. In conclusion, the PMD technique is an appropriate tool for characterizing occupational safety spectacle and injections mold surfaces. With the presented setup we were able to quantify the surface quality. This can be useful and may optimize the quality of the end product, in addition to standardized measuring systems in transmission

    Clinical Comparison of the Performance of Two Marketed Ophthalmic Viscoelastic Devices (OVDs): The Bacterially Derived Healon PRO OVD and Animal-Derived Healon OVD

    Get PDF
    This clinical investigation compared the clinical performance of two marketed ophthalmic viscoelastic devices (OVDs): the bacterially derived Healon PRO OVD (test) and the animal-derived Healon OVD (control) under normal use conditions during cataract removal and lens implantation. This prospective, multicenter, randomized, parallel, participant/evaluator masked, postmarket investigation enrolled 139 subjects (170 eyes), 116 (143 eyes) of which were treated (73 test; 70 control group). Both test and control OVDs were used, at a minimum, to inflate the anterior chamber and protect the endothelium prior to cataract extraction according to the standard procedure. The surgeon completed a postsurgery OVD clinical performance questionnaire, and intraocular pressure (IOP) was measured before surgery and at the 1 day postoperative visit with Goldmann applanation tonometry. Any IOP measurement of 30 mmHg or higher was considered a "spike"and recorded as a study-specific, serious adverse event. The bacterially derived Healon PRO OVD was found to be statistically noninferior to the overall clinical performance of the animal-derived Healon OVD control; thus, the primary hypothesis was satisfied. There were no statistically significant differences between OVD groups for any of the additional endpoints relating to IOP changes or to safety, thus satisfying additional hypotheses. The Healon PRO OVD showed statistically significant improvements in surgeon ratings for ease of injectability, transparency/visibility, and ease of IOL placement. The safety profile was also similar between OVD groups with regards to serious and/or device-related adverse events, as well as medical and lens findings. The results of this clinical investigation support the safety and effectiveness of the bacterially derived, currently marketed Healon PRO OVD and indicate that the intraocular surgical performance was similar between the two OVDs

    Analysis of Biomechanical Response After Corneal Crosslinking with Different Fluence Levels in Porcine Corneas.

    Get PDF
    PURPOSE To evaluate corneal stiffening of porcine corneas induced by corneal crosslinking (CXL) with constant irradiance as a function of total fluence. METHODS Ninety corneas from freshly enucleated porcine eyes were divided into five groups of 18 eyes. Groups 1-4 underwent epi-off CXL using a dextran-based riboflavin solution and an irradiance of 18 mW/cm2, group 5 served as the control group. Groups 1 to 4 were treated with a total fluence of 20, 15, 10.8, and 5.4 J/cm2, respectively. Thereafter, biomechanical measurements were performed on 5 mm wide and 6 mm long strips using an uniaxial material tester. Pachymetry measurements were performed on each cornea. RESULTS At 10% strain, the stress was 76, 56, 52, and 31% higher in groups 1-4, respectively compared to the control group. The Young's modulus was 2.85 MPa for group 1, 2.53 MPa for group 2, 2.46 MPa for group 3, 2.12 MPa for group 4, and 1.62 MPa for the control group. The difference between groups 1 to 4 and the control group 5 were statistically significant (p = <0.001; p = <0.001; p = <0.001; p = 0.021). In addition, group 1 showed significantly more stiffening than group 4 (p = <0.001), no other significant differences were found. Pachymetry measurements revealed no statistically significant differences among the five groups. CONCLUSION Additional mechanical stiffening can be achieved by increasing the fluence of the CXL. There was no threshold detected up to 20 J/cm2. A higher fluence could compensate the weaker effect of accelerated or epi-on CXL procedures

    APOBEC Mutagenesis Is Concordant between Tumor and Viral Genomes in HPV-Positive Head and Neck Squamous Cell Carcinoma

    Get PDF
    APOBEC is a mutagenic source in human papillomavirus (HPV)-mediated malignancies, including HPV+ oropharyngeal squamous cell carcinoma (HPV + OPSCC), and in HPV genomes. It is unknown why APOBEC mutations predominate in HPV + OPSCC, or if the APOBEC-induced mutations observed in both human cancers and HPV genomes are directly linked. We performed sequencing of host somatic exomes, transcriptomes, and HPV16 genomes from 79 HPV + OPSCC samples, quantifying APOBEC mutational burden and activity in both host and virus. APOBEC was the dominant mutational signature in somatic exomes. In viral genomes, there was a mean of five (range 0–29) mutations per genome. The mean of APOBEC mutations in viral genomes was one (range 0–5). Viral APOBEC mutations, compared to non-APOBEC mutations, were more likely to be low-variant allele fraction mutations, suggesting that APOBEC mutagenesis actively occurrs in viral genomes during infection. HPV16 APOBEC-induced mutation patterns in OPSCC were similar to those previously observed in cervical samples. Paired host and viral analyses revealed that APOBEC-enriched tumor samples had higher viral APOBEC mutation rates (p = 0.028), and APOBEC-associated RNA editing (p = 0.008), supporting the concept that APOBEC mutagenesis in host and viral genomes is directly linked and occurrs during infection. Using paired sequencing of host somatic exomes, transcriptomes, and viral genomes, we demonstrated for the first-time definitive evidence of concordance between tumor and viral APOBEC mutagenesis. This finding provides a missing link connecting APOBEC mutagenesis in host and virus and supports a common mechanism driving APOBEC dysregulation

    A review of the surgical options for the correction of presbyopia

    Get PDF
    Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia

    Evaluating real-time internet therapy and online self-help for problematic alcohol consumers: a three-arm RCT protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Only a minority of all alcohol- and drug abusers is receiving professional care. In an attempt to narrow this treatment gap, treatment facilities experiment with online healthcare. Therefore, it is important to test the (cost-)effectiveness of online health interventions in a randomized clinical trial.</p> <p>Methods</p> <p>This paper presents the protocol of a three-arm randomized clinical trial to test the (cost-) effectiveness of online treatment for problem drinkers. Self-help online, therapy online and a waiting list are tested against each other. Primary outcome is change in alcohol consumption. Secondary outcome measures include quality of life and working ability. Incremental cost-effectiveness ratios for self-help online alcohol and therapy online alcohol will be calculated. The predictive validity of participant characteristics on treatment adherence and outcome will be explored.</p> <p>Discussion</p> <p>To our best knowledge, this randomized clinical trial will be the first to test the effectiveness of therapy online against both self-help online and a waiting-list. It will provide evidence on (cost-) effectiveness of online treatment for problem drinkers and investigate outcome predictors.</p> <p>Trial registration</p> <p>This trial is registered in the Dutch Trialregister (Cochrane Collaboration) and traceable as NTR-TC1155.</p

    Considerations on the Castrop formula for calculation of intraocular lens power

    Get PDF
    Background: To explain the concept of the Castrop lens power calculation formula and show the application and results from a large dataset compared to classical formulae. Methods: The Castrop vergence formula is based on a pseudophakic model eye with 4 refractive surfaces. This was compared against the SRKT, Hoffer-Q, Holladay1, simplified Haigis with 1 optimized constant and Haigis formula with 3 optimized constants. A large dataset of preoperative biometric values, lens power data and postoperative refraction data was split into training and test sets. The training data were used for formula constant optimization, and the test data for cross-validation. Constant optimization was performed for all formulae using nonlinear optimization, minimising root mean squared prediction error. Results: The constants for all formulae were derived with the Levenberg-Marquardt algorithm. Applying these constants to the test data, the Castrop formula showed a slightly better performance compared to the classical formulae in terms of prediction error and absolute prediction error. Using the Castrop formula, the standard deviation of the prediction error was lowest at 0.45 dpt, and 95% of all eyes in the test data were within the limit of 0.9 dpt of prediction error. Conclusion: The calculation concept of the Castrop formula and one potential option for optimization of the 3 Castrop formula constants (C, H, and R) are presented. In a large dataset of 1452 data points the performance of the Castrop formula was slightly superior to the respective results of the classical formulae such as SRKT, Hoffer-Q, Holladay1 or Haigis
    • …
    corecore