219 research outputs found

    The memory space: Exploring future uses of Web 2.0 and mobile internet through design interventions.

    Get PDF
    The QuVis Quantum Mechanics Visualization project aims to address challenges of quantum mechanics instruction through the development of interactive simulations for the learning and teaching of quantum mechanics. In this article, we describe evaluation of simulations focusing on two-level systems developed as part of the Institute of Physics Quantum Physics resources. Simulations are research-based and have been iteratively refined using student feedback in individual observation sessions and in-class trials. We give evidence that these simulations are helping students learn quantum mechanics concepts at both the introductory and advanced undergraduate level, and that students perceive simulations to be beneficial to their learning.Comment: 15 pages, 5 figures, 1 table; accepted for publication in the American Journal of Physic

    Laue diffraction lenses for astrophysics: From theory to experiments

    Get PDF
    Based on the laws of X-ray diffraction in crystals, Laue lenses offer a promising way to achieve the sensitivity and angular resolution leap required for the next generation of hard X-ray and gamma-ray telescopes. The present paper describes the instrumental responses of Laue diffraction lenses designed for nuclear astrophysics. Different possible geometries are discussed, as well as the corresponding spectral and imaging capabilities. These theoretical predictions are then compared with Monte-Carlo simulations and experimental results (ground and stratospheric observations from the CLAIRE project)

    The Energy Spectrum of TeV Gamma-Rays from the Crab Nebula as measured by the HEGRA system of imaging air Cherenkov telescopes

    Full text link
    The Crab Nebula has been observed by the HEGRA (High-Energy Gamma-Ray Astronomy) stereoscopic system of imaging air Cherenkov telescopes (IACTs) for a total of about 200 hrs during two observational campaigns: from September 1997 to March 1998 and from August 1998 to April 1999. The recent detailed studies of system performance give an energy threshold and an energy resolution for gamma-rays of 500 GeV and ~ 18%, respectively. The Crab energy spectrum was measured with the HEGRA IACT system in a very broad energy range up to 20 TeV, using observations at zenith angles up to 65 degrees. The Crab data can be fitted in the energy range from 1 to 20 TeV by a simple power-law, which yields dJg/dE = (2.79+/-0.02 +/- 0.5) 10^{-7} E^{-2.59 +/- 0.03 +/- 0.05}, ph m^{-2} s^{-1} TeV^{-1} The Crab Nebula energy spectrum, as measured with the HEGRA IACT system, agrees within 15% in the absolute scale and within 0.1 units in the power law index with the latest measurements by the Whipple, CANGAROO and CAT groups, consistent within the statistical and systematic errors quoted by the experiments. The pure power-law spectrum of TeV gamma-rays from the Crab Nebula constrains the physics parameters of the nebula environment as well as the models of photon emission.Comment: to appear in ApJ, 29 pages, 6 figure

    Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates

    Full text link
    The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes extends beyond 16 TeV and constitutes the most energetic photons observed from an extragalactic object. A fraction of the emitted spectrum is possibly absorbed in interactions with low energy photons of the diffuse extragalactic infrared radiation, which in turn offers the unique possibility to measure the diffuse infrared radiation density by TeV spectroscopy. The upper limit on the density of the extragalactic infrared radiation derived from the TeV observations imposes constraints on models of galaxy formation and stellar evolution. One of the recently published ideas to overcome severe absorption of TeV photons is based upon the assumption that sources like Mrk 501 could produce Bose-Einstein condensates of coherent photons. The condensates would have a higher survival probability during the transport in the diffuse radiation field and could mimic TeV air shower events. The powerful stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this hypothesis by reconstructing the penetration depths of TeV air shower events: Air showers initiated by Bose-Einstein condensates are expected to reach the maximum of the shower development in the atmosphere earlier than single photon events. By comparing the energy-dependent penetration depths of TeV photons from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated air shower events, we can reject the hypothesis that TeV photons from Mrk 501 are pure Bose-Einstein condensates.Comment: 9 pages, 2 figures, published by ApJ Letters, revised version (simulation results added

    The TeV Energy Spectrum of Mkn 501 Measured with the Stereoscopic Telescope System of HEGRA during 1998 and 1999

    Full text link
    During 1997, the BL Lac object Mkn 501 went into an extraordinary state of high X-ray and TeV gamma-ray activity, lasting more than 6 months. In this paper we report on the TeV emission characteristics of the source in the subsequent years of 1998 and 1999 as measured with the Stereoscopic Cherenkov Telescope System of HEGRA (La Palma, Canary Islands). Our observations reveal a 1998-1999 mean emission level at 1 TeV of 1/3 of the flux of the Crab Nebula, a factor of 10 lower than during the year of 1997. A dataset of 122 observations hours with the HEGRA telescope system makes it possible to assess for the first time the Mkn 501 TeV energy spectrum for a mean flux level substantially below that of the Crab Nebula with reasonable statistical accuracy. Excluding the data of a strong flare, we find evidence that the 1998--1999 low-flux spectrum is substantially softer (by 0.44+-0.1(stat) in spectral index) than the 1997 time averaged spectrum. The 500 GeV to 10 TeV energy spectrum can well be described by a power law model with exponential cutoff: dN/dE ~ E^(-alpha) exp(-E/E0) with alpha=2.31+-0.22(stat), and E0=5.1 (-2.3+7.8)(stat) TeV. Within statistical accuracy, also a pure power law model gives an acceptable fit to the data: dN/dE ~ E^(-Gamma) with Gamma=2.76+-0.08(stat). After presenting the 1998-1999 TeV characteristics of the source we discuss the implications of the results.Comment: Accepted for publication in The Astrophysical Journal, Part 1, on August 4th, 200

    The unidentified TeV source (TeVJ2032+4130) and surrounding field: Final HEGRA IACT-System results

    Get PDF
    The unidentified TeV source in Cygnus is now confirmed by follow-up observations from 2002 with the HEGRA stereoscopic system of Cherenkov Telescopes. Using all data (1999 to 2002) we confirm this new source as steady in flux over the four years of data taking, extended with radius 6.2 arcmin (+-1.2 arcmin (stat) +-0.9 arcmin (sys)) and exhibiting a hard spectrum with photon index -1.9. It is located in the direction of the dense OB stellar association, Cygnus OB2. Its integral flux above energies E>1 TeV amounts to \~5% of the Crab assuming a Gaussian profile for the intrinsic source morphology. There is no obvious counterpart at radio, optical nor X-ray energies, leaving TeVJ2032+4130 presently unidentified. Observational parameters of this source are updated here and some astrophysical discussion is provided. Also included are upper limits for a number of other interesting sources in the FoV, including the famous microquasar Cygnus X-3.Comment: 7 pages, 3 figures. Accepted for publication in Astronomy & Astrophysic

    Evidence for TeV gamma ray emission from Cassiopeia A

    Get PDF
    232 hours of data were accumulated from 1997 to 1999, using the HEGRA Stereoscopic Cherenkov Telescope System to observe the supernova remnant Cassiopeia A. TeV gamma ray emission was detected at the 5 sigma level, and a flux of (5.8 +- 1.2(stat) +- 1.2(syst)) 10^(-9) ph m^(-2) s^(-1) above 1 TeV was derived. The spectral distribution is consistent with a power law with a differential spectral index of -2.5 +- 0.4(stat) +- 0.1(syst) between 1 and 10 TeV. As this is the first report of the detection of a TeV gamma ray source on the "centi-Crab" scale, we present the analysis in some detail. Implications for the acceleration of cosmic rays depend on the details of the source modeling. We discuss some important aspects in this paper.Comment: 9 pages, 6 figures, accepted for publication in Astronomy & Astrophysic

    Observations of H1426+428 with HEGRA -- Observations in 2002 and reanalysis of 1999&2000 data

    Get PDF
    The HEGRA system of imaging air Cherenkov telescopes has been used to observe the BL Lac object H1426+428 (z=0.129z=0.129) for 217.5 hours in 2002. In this data set alone, the source is detected at a confidence level of 5.3 σ5.3~\sigma, confirming this object as a TeV source. The overall flux level during the observations in 2002 is found to be a factor of 2.5\approx 2.5 lower than during the previous observations by HEGRA in 1999&2000. A new spectral analysis has been carried out, improving the signal-to-noise ratio at the expense of a slightly increased systematic uncertainty and reducing the relative energy resolution to ΔE/E12\Delta E/E\le 12 % over a wide range of energies. The new method has also been applied to the previously published data set taken in 1999 and 2000, confirming the earlier claim of a flattening of the energy spectrum between 1 and 5 TeV. The data set taken in 2002 shows again a signal at energies above 1 TeV. We combine the energy spectra as determined by the CAT and VERITAS groups with our reanalyzed result of the 1999&2000 data set and apply a correction to account for effects of absorption of high energy photons on extragalactic background light in the optical to mid infrared band. The shape of the inferred source spectrum is mostly sensitive to the characteristics of the extragalactic background light between wavelengths of 1 and 15~μ\mumComment: 12 pages, 4 Figures, submitted to A&

    Disorder Effects on Exciton-Polariton Condensates

    Full text link
    The impact of a random disorder potential on the dynamical properties of Bose Einstein condensates is a very wide research field. In microcavities, these studies are even more crucial than in the condensates of cold atoms, since random disorder is naturally present in the semiconductor structures. In this chapter, we consider a stable condensate, defined by a chemical potential, propagating in a random disorder potential, like a liquid flowing through a capillary. We analyze the interplay between the kinetic energy, the localization energy, and the interaction between particles in 1D and 2D polariton condensates. The finite life time of polaritons is taken into account as well. In the first part, we remind the results of [G. Malpuech et al. Phys. Rev. Lett. 98, 206402 (2007).] where we considered the case of a static condensate. In that case, the condensate forms either a glassy insulating phase at low polariton density (strong localization), or a superfluid phase above the percolation threshold. We also show the calculation of the first order spatial coherence of the condensate versus the condensate density. In the second part, we consider the case of a propagating non-interacting condensate which is always localized because of Anderson localization. The localization length is calculated in the Born approximation. The impact of the finite polariton life time is taken into account as well. In the last section we consider the case of a propagating interacting condensate where the three regimes of strong localization, Anderson localization, and superfluid behavior are accessible. The localization length is calculated versus the system parameters. The localization length is strongly modified with respect to the non-interacting case. It is infinite in the superfluid regime whereas it is strongly reduced if the fluid flows with a supersonic velocity.Comment: chapter for a book "Exciton Polaritons in Microcavities: New Frontiers" by Springer (2012), the original publication is available at http://www.springerlink.co
    corecore