453 research outputs found

    All-dielectric crescent metasurface sensor driven by bound states in the continuum

    Get PDF
    Metasurfaces based on quasi-bound states in the continuum (quasi-BICs) constitute an emerging toolkit in nanophotonic sensing as they sustain high quality factor resonances and substantial near-field enhancements. It is demonstrated that silicon metasurfaces composed of crescent shaped meta-atoms provide tailored light-matter interaction controlled by the crescent geometry. Significantly, this metasurface not only exhibits a fundamental quasi-BIC resonance, but also supports a higher-order resonance with tunable electromagnetic field enhancement and advantageous properties for sensing. The higher-order resonance shows twice the sensitivity of the fundamental one for bulk refractive index sensing. It is further demonstrated that both the fundamental and higher-order resonances can be exploited for sensing ultrathin layers of biomolecules in air and buffer solutions. Specifically, when measuring in buffer solution, the figure of merit of the sensor, defined as the change in the spectral position of the resonance normalized to its full width at half maximum, is a factor of 2.5 larger for the higher-order resonance when compared to the fundamental one. Due to its high sensitivity and potential for straightforward microfluidic integration, the silicon crescent metasurface is ideally suited for real-time and in situ biosensing, enabling compact sensing devices for a wide range of diagnostic applications

    Fluorine-19 MRI at 21.1 T: enhanced spin-lattice relaxation of perfluoro-15-crown-5-ether and sensitivity as demonstrated in ex vivo murine neuroinflammation

    Get PDF
    OBJECTIVE: Fluorine MR would benefit greatly from enhancements in signal-to-noise ratio (SNR). This study examines the sensitivity gain of (19)F MR that can be practically achieved when moving from 9.4 to 21.1 T. MATERIALS AND METHODS: We studied perfluoro-15-crown-5-ether (PFCE) at both field strengths (B(0)), as a pure compound, in the form of nanoparticles (NP) as employed to study inflammation in vivo, as well as in inflamed tissue. Brains, lymph nodes (LNs) and spleens were obtained from mice with experimental autoimmune encephalomyelitis (EAE) that had been administered PFCE NPs. All samples were measured at both B(0) with 2D-RARE and 2D-FLASH using (19)F volume radiofrequency resonators together. T(1) and T(2) of PFCE were measured at both B(0) strengths. RESULTS: Compared to 9.4 T, an SNR gain of > 3 was observed for pure PFCE and > 2 for PFCE NPs at 21.1 T using 2D-FLASH. A dependency of (19)F T(1) and T(2) relaxation on B(0) was demonstrated. High spatially resolved (19)F MRI of EAE brains and LNs at 21.1 T revealed signals not seen at 9.4 T. DISCUSSION: Enhanced SNR and T(1) shortening indicate the potential benefit of in vivo (19)F MR at higher B(0) to study inflammatory processes with greater detail

    Local multi-channel RF surface coil versus body RF coil transmission for cardiac magnetic resonance at 3 Tesla: which configuration is winning the game?

    Get PDF
    INTRODUCTION: The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS: Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. RESULTS: Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. CONCLUSION: Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants

    Influence of Chloride and Nitrate Anions on Copper Electrodeposition onto Au(111) from Deep Eutectic Solvents

    Get PDF
    Copper electrodeposition on Au(111) from deep eutectic solvents (DESs) type III was investigated employing cyclic voltammetry as well as chronoamperometry. It was further examined on Au(poly) using the electrochemical quartz crystal microbalance (EQCM). The employed DESs are mixtures of choline chloride (ChCl) or choline nitrate (ChNO3_{3}) with ethylene glycol (EG) as hydrogen bond donor (HBD), each in a molar ratio of 1 : 2. CuCl, CuCl2_{2}, or Cu(NO3_{3})2_{2} ⋅ 3H2_{2}O were added as copper sources. Underpotential deposition (UPD) of Cu precedes bulk deposition in chloride as well as nitrate electrolytes. Cu deposition from Cu+^{+} in chloride media is observed as a one-electron reaction, whereas deposition from Cu2+^{2+} occurs in two steps since Cu+^{+} is strongly stabilized by chloride. Cu+^{+} is less stabilized by nitrate and the beginning of bulk deposition in the nitrate-containing DES with Cu2+^{2+} is shifted by several hundred mV to more positive potentials compared to the chloride DES. A diffusion-controlled, three-dimensional nucleation and growth mechanism is found by chronoamperometric measurements and analysis based on the model of Scharifker and Mostany

    Combining Deep Eutectic Solvents with TEMPO‐based Polymer Electrodes: Influence of Molar Ratio on Electrode Performance

    Get PDF
    For sustainable energy storage, all-organic batteries based on redox-active polymers promise to become an alternative to lithium ion batteries. Yet, polymers contribute to the goal of an all-organic cell as electrodes or as solid electrolytes. Here, we replace the electrolyte with a deep eutectic solvent (DES) composed of sodium bis(trifluoromethanesulfonyl)imide (NaTFSI) and N-methylacetamide (NMA), while using poly(2,2,6,6-tetramethylpiperidin-1-yl-oxyl methacrylate) (PTMA) as cathode. The successful combination of a DES with a polymer electrode is reported here for the first time. The electrochemical stability of PTMA electrodes in the DES at the eutectic molar ratio of 1 : 6 is comparable to conventional battery electrolytes. More viscous electrolytes with higher salt concentration can hinder cycling at high rates. Lower salt concentration leads to decreasing capacities and faster decomposition. The eutectic mixture of 1 : 6 is best suited uniting high stability and moderate viscosity

    A novel coil array for combined TMS/fMRI experiments at 3 T

    Get PDF
    PURPOSE: To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. METHODS: The state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7-channel receive-only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state-of-the-art setup. RESULTS: MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g-factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible. CONCLUSION: The novel coil array is safe, strongly improves signal-to-noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design

    Patient-specific planning for thermal magnetic resonance of glioblastoma multiforme

    Get PDF
    Thermal intervention is a potent sensitizer of cells to chemo- and radiotherapy in cancer treatment. Glioblastoma multiforme (GBM) is a potential clinical target, given the cancer's aggressive nature and resistance to current treatment options. This drives research into optimization algorithms for treatment planning as well as radiofrequency (RF) applicator design for treatment delivery. In this work, nine clinically realistic GBM target volumes (TVs) for thermal intervention are compared using three optimization algorithms and up to ten RF applicator designs for thermal magnetic resonance. Hyperthermia treatment planning (HTP) was successfully performed for all cases, including very small, large, and even split target volumes. Minimum requirements formulated for the metrics assessing HTP outcome were met and exceeded for all patient specific cases. Results indicate a 16 channel two row arrangement to be most promising. HTP of TVs with a small extent in the cranial–caudal direction in conjunction with a large radial extent remains challenging despite the advanced optimization algorithms used. In general, deep seated targets are favorable. Overall, our findings indicate that a one-size-fits-all RF applicator might not be the ultimate approach in hyperthermia of brain tumors. It stands to reason that modular and reconfigurable RF applicator configurations might best suit the needs of targeting individual GBM geometry

    Radiofrequency applicator concepts for thermal magnetic resonance of brain tumors at 297 MHz (7.0 Tesla)

    Get PDF
    PURPOSE: Thermal intervention is a potent sensitizer of cells to chemo- and radiotherapy in cancer treatment. Glioblastoma multiforme (GBM) is a potential clinical target, given the cancer's aggressive nature and resistance to current treatment options. The annular phased array (APA) technique employing electromagnetic waves in the radiofrequency (RF) range allows for localized temperature increase in deep seated target volumes (TVs). Reports on clinical applications of the APA technique in the brain are still missing. Ultrahigh field magnetic resonance (MR) employs higher frequencies than conventional MR and has potential to provide focal temperature manipulation, high resolution imaging and noninvasive temperature monitoring using an integrated RF applicator (ThermalMR). This work examines the applicability of RF applicator concepts for ThermalMR of brain tumors at 297 MHz (7.0 Tesla). METHODS: Electromagnetic field (EMF) simulations are performed for clinically realistic data based on GBM patients. Two algorithms are used for specific RF energy absorption rate based thermal intervention planning for small and large TVs in the brain, aiming at maximum RF power deposition or RF power uniformity in the TV for 10 RF applicator designs. RESULTS: For both TVs , the power optimization outperformed the uniformity optimization. The best results for the small TV are obtained for the 16 element interleaved RF applicator using an elliptical antenna arrangement with water bolus. The two row elliptical RF applicator yielded the best result for the large TV. DISCUSSION: This work investigates the capacity of ThermalMR to achieve targeted thermal interventions in model systems resembling human brain tissue and brain tumors

    Conjugated Polyimidazole Nanoparticles as Biodegradable Electrode Materials for Organic Batteries

    Get PDF
    Conjugated polymers are promising active materials for batteries. Batteries not only need to have high energy density but should also combine safe handling with recyclability or biodegradability after reaching their end-of-life. Here, π-conjugated polyimidazole particles are developed, which are prepared using atom economic direct arylation adapted to a dispersion polymerization protocol. The synthesis yields polyimidazole nanoparticles of tunable size and narrow dispersity. In addition, the degree of crosslinking of the polymer particles can be controlled. It is demonstrated that the polyimidazole nanoparticles can be processed together with carbon black and biodegradable carboxymethyl cellulose binder as an active material for organic battery electrodes. Electrochemical characterization shows that a higher degree of crosslinking significantly improves the electrochemical performance and leads to clearer oxidation and reduction signals of the polymer. Polyimidazole as part of the composite electrode shows complete degradation by exposure to composting bacteria over the course of 72 h
    corecore