2,332 research outputs found

    Ultrafast Linear Kinetic Inductive Photoresponse of YBa2Cu3O7-{\delta} Meander-Line Structures by Photoimpedance Measurements

    Full text link
    We report the experimental demonstration of linear kinetic-inductive photoresponse of thin-film YBa2Cu3O7-{\delta} (YBCO) meander-line structures, where the photoresponse amplitude, full-width-half-maximum (FWHM), and rise-time are bilinear in the incident optical power and bias current. This bilinear behavior reveals a trade off between obtaining high responsivity and high speed photodetection. We also report a rise-time as short as 29ps in our photoimpedance measurements.Comment: 3 pages, 6 figures, submitted to AP

    A redescription of Diogenes senex Heller, 1865, sensu stricto (Decapoda: Anomura: Paguridea: Diogenidae)

    Get PDF
    Diogenes senex Heller, 1865 sensu stricto is redescribed from specimens collected in Australia, particularly in and around the type locality of Sydney. A neotype has been designated. Comparisons of this material with other specimens identified as D. senex by a number of authors has shown that at present only the Australian material truly represents Heller's taxon

    Integrated high quality factor lithium niobate microdisk resonators

    Full text link
    Lithium Niobate (LN) is an important nonlinear optical material. Here we demonstrate LN microdisk resonators that feature optical quality factor ~ 100,000, realized using robust and scalable fabrication techniques, that operate over a wide wavelength range spanning visible and near infrared. Using our resonators, and leveraging LN's large second order optical nonlinearity, we demonstrate on-chip second harmonic generation with a conversion efficiency of 0.109 W-1

    Asymmetric masks for large field-of-view and high-energy X-ray phase contrast imaging

    Get PDF
    We report on a large field of view, laboratory-based X-ray phase-contrast imaging setup. The method is based upon the asymmetric mask design that enables the retrieval of the absorption, refraction and scattering properties of the sample without the need to move any component of the imaging system. This can be thought of as a periodic repetition of a group of three (or more) apertures arranged in such a way that each laminar beam, defined by the apertures, produces a different illumination level when analysed with a standard periodic set of apertures. The sample is scanned through the imaging system, also removing possible aliasing problems that might arise from partial sample illumination when using the edge illumination technique. This approach preserves the incoherence and achromatic properties of edge illumination, removes the problems related to aliasing and it naturally adapts to those situations in clinical, industrial and security imaging where the image is acquired by scanning the sample relative to the imaging system. These concepts were implemented for a large field-of-view set of masks (20 cm × 1.5 cm and 15 cm × 1.2 cm), designed to work with a tungsten anode X-ray source operated up to 80–100 kVp, from which preliminary experimental results are presented

    Large field-of-view asymmetric masks for high-energy x-ray phase imaging with standard x-ray tube

    Get PDF
    We report on a new approach to large field-of-view laboratory-based X-ray phase-contrast imaging. The method is based upon the asymmetric mask design that enables the retrieval of the absorption, refraction and ultra-small- angle scattering properties of the sample without the need to move any component of the imaging system. The sample is scanned through the imaging system, which also removes possible aliasing problems that might arise from partial sample illumination when using the edge illumination technique. This concept can be extended to any desired number of apertures providing, at the same time, intensity projections at complementary illumination conditions. Experimental data simultaneously acquired at seven different illumination fractions are presented along with the results obtained from a numerical model that incorporates the actual detector performance. The ultimate shape of the illumination function is shown to be significantly dependent on these detector-specific characteristics. Based on this concept, a large field-of-view system was designed, which is also capable to cope with relatively high (100 kVp) X-ray energies. The imaging system obtained in this way, where the asymmetric mask design enables the data to be collected without moving any element of the instrumentation, adapts particularly well to those situations in medical, industrial and security imaging where the sample has to be scanned through the syste

    Early Cretaceous biogeographic and oceanographic synthesis of Leg 123 (off Northwestern Australia)

    Get PDF
    Biogeographic observations made by Leg 123 shipboard paleontologists for Lower Cretaceous nannofossils, foraminifers, radiolarians, belemnites, and inoceramids are combined in this chapter to evaluate the paleoceanographic history of the northwestern Australian margin and adjacent basins. Each fossil group is characterized at specific intervals of Cretaceous time and compared with data from Tethyan and Southern Hemisphere high-latitude localities. Special attention is given to the biogeographic observations made for the Falkland Plateau (DSDP Legs 36 and 71) and the Weddell Sea (ODP Leg 113). Both areas have yielded valuable Lower Cretaceous fossil records of the circumantarctic high latitudes. In general, the Neocomian fossil record from DSDP and ODP sites off northwestern Australia has important southern high-latitude affinities and weak Tethyan influence. The same is true for the pelagic lithofacies: radiolarian chert and/or nannofossil limestone, dominant in the Tethyan Lower Cretaceous, are minor lithologies in the Exmouth-Argo sites. These observations, together with the young age of the Argo crust and plate tectonic considerations, suggest that the Argo Basin was not part of the Tethys Realm. The biogeography of the Neocomian radiolarian and nannofossil assemblages suggests opening of a seaway during the Berriasian that connected the circumantarctic area with the Argo Basin, which resulted in the influx of southern high-latitude waters. This conclusion constrains the initial fit and break-up history of Gondwana. Our results favor the loose fit of the western Australian margin with southeast India by Ricou et al. (1990), which accounts for a deeper water connection with the Weddell-Mozambique basins via drowned marginal plateaus as early as the Berriasian. In fits of the du Toit-type (1937), India would remain attached to Antarctica, at least until the late Valanginian, making such a connection impossible. After the Barremian, increasing Tethyan influence is evident in all fossil groups, although southern high-latitude taxa are still present. Biogeographic domains, such as the southern extension of Nannoconus and Ticinella suggest paleolatitudes of about 50°S for the Exmouth-Argo area. Alternatively, if paleolatitudes of about 35° are accepted, these biogeographic limits were displaced northward at least 15° along Australia in comparison to the southern Atlantic. In this case, the proto-circumantarctic current was deflected northward into an eastern boundary current off Australia and carried circumantarctic cold water into the middle latitudes. Late Aptian/early Albian time is characterized by mixing of Tethyan and southern faunal elements and a significant gradient in Albian surface-water temperatures over 10° latitude along the Australian margin, as indicated by planktonic foraminifers. Both phenomena may be indicative of convergence of temperate and antarctic waters near the Australian margin. High fertility conditions, reflected by radiolarian cherts, are suggestive of coastal upwelling during that time

    Efficient Single Photon Absorption by Optimized Superconducting Nanowire Geometries

    Full text link
    We report on simulation results that shows optimum photon absorption by superconducting nanowires can happen at a fill-factor that is much less than 100%. We also present experimental results on high performance of our superconducting nanowire single photon detectors realized using NbTiN on oxidized silicon.Comment: \copyright 2013 IEEE. Submitted to "Numerical Simulation of Optoelectronic Devices - NUSOD 2013" on 19-April-201
    corecore