3,011 research outputs found

    Relationship between perceived and actual quality of data checking

    Full text link
    Data quality is critical to reaching correct research conclusions. Researchers attempt to ensure that they have accurate data by checking the data after it has been entered. Previous research has demonstrated that some methods of data checking are better than others, but not all researchers use the best methods. Perhaps researchers continue to use less optimal data checking methods because they mistakenly believe that they are highly accurate. The purpose of this study was to examine the relationship between perceived data quality and actual data quality. A total of 29 participants completed this study. Participants checked that letters and numbers had been entered correctly into the computer using one of three randomly assigned data checking methods. Afterwards, they rated the quality of their data checking method. The sample correlations between perceived and actual data quality were small to moderate and confidence intervals for the population correlations did not include high values. We conclude that the relationship between actual and perceived data quality is not high

    SOLUBILITY LIMIT OF DOPANTS IN SILICON IRRADIATED BY RUBY LASER

    No full text
    The solubility of several dopants (Sb, Ga, Bi, In) in laser treated silicon has been investigated. The dopants were introduced by vacuum deposition followed by a ruby laser irradiation. Their solubility was determined by Rutherford backscattering spectrometry measurements in channeling and random conditions. In all cases a solubility limit Cmℓ higher than the equilibrium solubility was found and a simple correlation with the equilibrium distribution coefficient kO could be established : Cmℓ = 8.6 × 1021 k0.51O cm-3

    Nanoladder cantilevers made from diamond and silicon

    Full text link
    We present a "nanoladder" geometry that minimizes the mechanical dissipation of ultrasensitive cantilevers. A nanoladder cantilever consists of a lithographically patterned scaffold of rails and rungs with feature size \sim 100 nm. Compared to a rectangular beam of the same dimensions, the mass and spring constant of a nanoladder are each reduced by roughly two orders of magnitude. We demonstrate a low force noise of 158(+62)(42)158 (+62)(-42)\,zN and 190(+42)(33)190 (+42)(-33)\,zN in a one-Hz bandwidth for devices made from silicon and diamond, respectively, measured at temperatures between 100--150 mK. As opposed to bottom-up mechanical resonators like nanowires or nanotubes, nanoladder cantilevers can be batch-fabricated using standard lithography, which is a critical factor for applications in scanning force microscopy

    Development of a German version of the Oswestry Disability Index. Part 1: cross-cultural adaptation, reliability, and validity

    Get PDF
    Patient-orientated assessment methods are of paramount importance in the evaluation of treatment outcome. The Oswestry Disability Index (ODI) is one of the condition-specific questionnaires recommended for use with back pain patients. To date, no German version has been published in the peer-reviewed literature. A cross-cultural adaptation of the ODI for the German language was carried out, according to established guidelines. One hundred patients with chronic low-back pain (35 conservative, 65 surgical) completed a questionnaire booklet containing the newly translated ODI, along with a 0-10 pain visual analogue scale (VAS), the Roland Morris Disability Questionnaire, and Likert scales for disability, medication intake and pain frequency [to assess ODI's construct (convergent) validity]. Thirty-nine of these patients completed a second questionnaire within 2weeks (to assess test-retest reliability). The intraclass correlation coefficient for the test-retest reliability of the questionnaire was 0.96. In test-retest, 74% of the individual questions were answered identically, and 21% just one grade higher or lower. The standard error of measurement (SEM) was 3.4, giving a "minimum detectable change” (MDC95%) for the ODI of approximately 9 points, i.e. the minimum change in an individual's score required to be considered "real change” (with 95% confidence) over and above measurement error. The ODI scores correlated with VAS pain intensity (r=0.78, P<0.001) and Roland Morris scores (r=0.80, P<0.001). The mean baseline ODI scores differed significantly between the surgical and conservative patients (P<0.001), and between the different categories of the Likert scales for disability, medication use and pain frequency (in each case P<0.001). Our German version of the Oswestry questionnaire is reliable and valid, and shows psychometric characteristics as good as, if not better than, the original English version. It should represent a valuable tool for use in future patient-orientated outcome studies in German-speaking land

    Development of a German version of the Oswestry Disability Index. Part 2: sensitivity to change after spinal surgery

    Get PDF
    When functional scales are to be used as treatment outcome measures, it is essential to know how responsive they are to clinical change. This information is essential not only for clinical decision-making, but also for the determination of sample size in clinical trials. The present study examined the responsiveness of a German version of the Oswestry Disability Index version 2.1 (ODI) after surgical treatment for low back pain. Before spine surgery 63 patients completed a questionnaire booklet containing the ODI, along with a 0-10 pain visual analogue scale (VAS), the Roland Morris disability questionnaire, and Likert scales for disability, medication intake and pain frequency. Six months after surgery, 57 (90%) patients completed the same questionnaire booklet and also answered Likert-scale questions on the global result of surgery, and on improvements in pain and disability. Both the effect size for the ODI change score 6months after surgery (0.87) and the area under the receiver operating characteristics (ROC) curve for the relative improvement in ODI score in relation to global outcome 6months after surgery (0.90) indicated that the ODI showed good responsiveness. The ROC method revealed that a minimum reduction of the baseline (pre-surgery) ODI score by 18% (equal to a mean 8-point reduction in this patient group) represented the cut-off for indicating a "good” individual outcome 6months after surgery (sensitivity 91.4% and specificity 82.4%). The German version of the ODI is a sensitive instrument for detecting clinical change after spinal surgery. Individual improvements after surgery of at least an 18% reduction on baseline values are associated with a good outcome. This figure can be used as a reliable guide for the determination of sample size in future clinical trials of spinal surger

    SSE Spine Tango - content, workflow, set-up: www.eurospine.org - Spine Tango

    Get PDF
    The Spine Tango registry is now accessible via the SSE webpage under www.eurospine.org - Spine Tango. Links to the Swiss/International, German and Austrian modules are provided as well as information about the philosophy, methodology and content. Following the links, the users are taken to the respective national modules for registration or log-in and data entry. The Swiss/International module, also accessible under www.spinetango.com, is used by all Swiss and international users, who do not have a separate national module. The physician administered forms for surgery, staged surgery and follow-up can be downloaded as PDFs.The officially recommended Spine Tango patient forms are also available. All forms were implemented in an online version and as scannable optical mark reader forms which can be ordered from the corresponding autho

    On the Theory of Magnetotransport in a Periodically Modulated Two-Dimensional Electron Gas

    Full text link
    A semiclassical theory based on the Boltzmann transport equation for a two-dimensional electron gas modulated along one direction with weak electrostatic or magnetic modulations is proposed. It is shown that oscillations of the magnetoresistivity ρ \rho_{||} corresponding to the current driven along the modulation lines observed at moderately low magnetic fields, can be explained as classical geometric resonances reflecting the commensurability of the period of spatial modulations and the cyclotron radius of electrons.Comment: 5 pages, 1 figure, text and 1 figure adde
    corecore