242 research outputs found

    Calculating, Interpreting, And Reporting Cronbach’s Alpha Reliability Coefficient For Likert-Type Scales

    Get PDF
    The purpose of this paper is to show why single-item questions pertaining to a construct are not reliable and should not be used in drawing conclusions. By comparing the reliability of a summated, multi-item scale versus a single-item question, the authors show how unreliable a single item is; and therefore it is not appropriate to make inferences based upon the analysis of single-item questions which are used in measuring a construct

    An Economic Evaluation of Emerging Variable Rate Application Technologies

    Get PDF
    Author Institution (Batte and Schnitkey): Department of Agricultural, Environmental and Developmental Economics, The Ohio State Universit

    2 nd Runner-Up Outstanding Paper presented at the 19 th Annual Association for International Agricultural and Extension Education Conference

    Get PDF
    Abstract This descriptive-correlational study investigated Ohio State University (O.S.U.) Extension county agent

    Isotopic Composition of Solar Wind Calcium: First in Situ Measurement by CELIAS/MTOF on Board SOHO

    Get PDF
    We present first results on the Ca isotopic abundances derived from the high resolution Mass Time-of-Flight (MTOF) spectrometer of the charge, element, and isotope analysis system (CELIAS) experiment on board the Solar and Heliospheric Observatory (SOHO). We obtain isotopic ratios 40Ca/42Ca = (128+-47) and 40Ca/44Ca = (50+-8), consistent with terrestrial values. This is the first in situ determination of the solar wind calcium isotopic composition and is important for studies of stellar modeling and solar system formation since the present-day solar Ca isotopic abundances are unchanged from their original isotopic composition in the solar nebula.Comment: 14 pages, 3 figure

    Assessment of esophageal motility disorders by real-time MRI

    Get PDF
    Purpose To investigate imaging findings of esophageal motility disorders on dynamic real-time. Material and methods 102 patients with GERD-like symptoms were included in this retrospective study between 2015−2018. Dynamic real-time MRI visualized the transit of a 10 mL pineapple juice bolus through the esophagus and EGJ with a temporal resolution of 40 ms. Dynamic and anatomic parameters were measured by consensus reading. Imaging findings were compared to HRM utilizing the Chicago classification of esophageal motility disorders, v3.0. Results All 102 patients completed real-time MRI in a median examination time of 15 min. On HRM, 14 patients presented with disorders with EGJ outlet obstruction (EGJOO) (13.7 %), 7 patients with major disorders of peristalsis (6.9 %), and 32 patients with minor disorders of peristalsis (31.4 %). HRM was normal in 49 patients (48.0 %). Incomplete bolus clearance was significantly more frequent in patients with esophageal motility disorders on HRM than in patients with normal HRM (p = 0.0002). In patients with motility disorders with EGJOO and major disorders of peristalsis, the esophageal diameter tended to be wider (23.6 ± 8.0 vs. 21.2 ± 3.5 mm, p = 0.089) and the sphincter length longer (19.7 ± 7.3 vs. 16.7 ± 3.0 mm, p = 0.091) compared to patients with normal HRM. 3/7 patients with achalasia type II were correctly identified by real-time MRI and one further achalasia type II patient was diagnosed with a motility disorder on MRI films. The other 3/7 patients presented no specific imaging features. Conclusion Real-time MRI is an auxiliary diagnostic tool for the assessment of swallowing events. Imaging parameters may assist in the detection of esophageal motility disorders

    Assessment of esophagogastric junction morphology by dynamic real-time MRI: comparison of imaging features to high-resolution manometry

    Get PDF
    Purpose To assess the esophagogastric junction (EGJ) on real-time MRI and compare imaging parameters to EGJ morphol- ogy on high-resolution manometry (HRM). Methods A total of 105 of 117 eligible patients who underwent real-time MRI and high-resolution manometry for GERD- like symptoms between 2015 and 2018 at a single center were retrospectively evaluated (male n = 57; female n = 48; mean age 52.5 ± 15.4 years). Real-time MRI was performed at a median investigation time of 15 min (1 frame/40 ms). On HRM, EGJ morphology was assessed according to the Chicago classification of esophageal motility disorders. Real-time MRI was performed at 3 T using highly undersampled radial fast low-angle shot acquisitions with NLINV image reconstruction. A 10 mL pineapple juice bolus served as oral contrast agent at supine position. Real-time MRI films of the EGJ were acquired during swallowing events and during Valsalva maneuver. Anatomic and functional MRI parameters were compared to EGJ morphology on HRM. Results On HRM, n = 42 patients presented with EGJ type I (40.0%), n= 33 with EGJ type II (31.4%), and n= 30 with EGJ type III (28.6%). On real-time MRI, hiatal hernia was more common in patients with EGJ type III (66.7%) than in patients with EGJ type I (26.2%) and EGJ type II (30.3%; p < 0.001). Sliding hiatal hernia was more frequent in patients with EGJ type II (33.3%) than in patients with EGJ type III (16.7%) and EGJ type I (7.1%; p = 0.017). The mean esophagus–fundus angle of patients was 85 ± 31° at rest and increased to 101 ± 36° during Valsalva maneuver. Conclusion Real-time MRI is a non-invasive imaging method for assessment of the esophagogastric junction. Real-time MRI can visualize dynamic changes of the EGJ during swallowing events

    Real-time MRI for dynamic assessment of gastroesophageal reflux disease: comparison to pH-metry and impedance

    Get PDF
    Purpose To evaluate the diagnostic potential of real-time MRI for dynamic assessment of gastroesophageal reflux in patients with GERD (gastroesophageal reflux disease)-like symptoms compared to pH-metry and impedance. Methods Patients who underwent real-time MRI and pH-metry between 2015–2018 were included in this retrospective study. Real-time MRI at 3 T was achieved by undersampled radial FLASH acquisitions with iterative image reconstruction by NLINV. Real-time MRI visualized transit of pineapple juice through the gastroesophageal junction and during Valsalva maneuver. MRI results were compared to 24 h pH-metry to assess acidic reflux (following Lyon Consensus guidelines) and to impedance to assess non-acidic reflux. A standard 2 × 2 table was chosen to calculate diagnostic performance. Results 91/93 eligible patients fulfilled inclusion criteria (male n = 49; female n = 42; median age 55 y). All MRI studies were successfully completed without adverse events at a mean examination time of 15 min. On real-time MRI, reflux was evident in 60 patients (66 %). pH-metry revealed reflux in 41 patients (45 %), and impedance in 54 patients (59 %). Compared to pH-metry and impedance, real-time MRI sensitivity was 0.78 (95 % CI: 0.66-0.87), specificity 0.67 (95 % CI: 0.45-0.84) and PPV 0.87 (95 % CI: 0.75-0.94). Conclusion Real-time MRI is an imaging method for assessment of gastroesophageal reflux in patients with GERD-like symptoms. Considering its high positive predictive value, real-time MRI can accurately identify patients in which further invasive testing with pH-metry and impedance might be considered

    An integrated space physics instrument (ISPI) for Solar Probe

    Full text link
    Instruments for the Solar Probe mission must be designed not only to address the unique scientific measurement requirements, but must be compatible with the modest resource dollars as well as tight constraints on mass and power. Another unique aspect of the Solar Probe mission is its constraint on telemetry and the fact that the prime science is conducted in a single flyby. The instrument system must be optimized to take advantage of the telemetry and observing time available. JPL, together with industry and university partners, is designing an Integrated Space Physics Instrument (ISPI) which will measure magnetic fields, plasma waves, thermal plasma, energetic particles, dust, and perform EUV/visible and coronal imaging for the Solar Probe mission. ISPI uses a new architecture and incorporates technology which not only eliminates unnecessary duplication of function, but allows sensors to share data and optimize science. The current ISPI design goal (for a flight package) is a 5 kilogram/10 watt payload. © 1997 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87393/2/131_1.pd

    aPRIDIT Unsupervised Classification with Asymmetric Valuation of Variable Discriminatory Worth

    Get PDF
    Sometimes one needs to classify individuals into groups, but there is no available grouping information due to social desirability bias in reporting behavior like unethical or dishonest intentions or unlawful actions. Assessing hard-to-detect behaviors is useful; however it is methodologically difficult because people are unlikely to self-disclose bad actions. This paper presents an unsupervised classification methodology utilizing ordinal categorical predictor variables. It allows for classification, individual respondent ranking, and grouping without access to a dependent group indicator variable. The methodology also measures predictor variable worth (for determining target behavior group membership) at a predictor variable category-by-category level, so different variable response categories can contain different amounts of information about classification. It is asymmetric in that a “0” on a binary predictor does not have a similar impact toward signaling “membership in the target group” as a “1” has for signaling “membership in the non-target group.” The methodology is illustrated by identifying Spanish consumers filing fraudulent insurance claims. A second illustration classifies Portuguese high school student’s propensity to alcohol abuse. Results show the methodology is useful when it is difficult to get dependent variable information, and is useful for deciding which predictor variables and categorical response options are most important

    Validation of a Persian version of the OIDP index

    Get PDF
    BACKGROUND: Measuring the impacts of oral conditions on quality of life is an important part of oral health needs assessment. For this purpose a variety of oral health-related quality of life instruments have been developed. To use a scale in a new context or with a different groups of people, it is necessary to re-establish its psychometric properties. The objectives of this study are to develop and test the reliability and validity of the Persian version of Oral Impacts on Daily Performances (OIDP) index. METHODS: The Persian version of OIDP index was developed through a linguistic translation exercise. The psychometric properties of the Persian version of OIDP were evaluated in terms of face, content, construct and criterion validity in addition to internal and test-retest reliability. A convenience sample of 285 working adults aged 20–50 living in Mashad was recruited (91% response rate) to evaluate the Persian version. RESULTS: The Persian version of OIDP had excellent validity and reliability charactersitics. Weighted Kappa was 0.91. Cronbachs alpha coefficient was 0.79. The index showed significant associations with self-rated oral and general health status, as well as perceived dental treatment needs, satisfaction with mouth and prevalence of pain in mouth (P < 0.001). 64.9% of subjects had an oral impact on their daily performances. The most prevalent performance affected was eating, followed by major work or role and sleeping. CONCLUSION: The Persian version of OIDP index is a valid and reliable measure for use in 20 to 50 year old working Iranians
    • 

    corecore