367 research outputs found
Motion of magnetotactic bacteria swarms in an external field
Magnetotactic bacteria moving on circular orbits form hydrodynamically bound
states. When close to a surface and with the tilting of the field in a
direction close to the perpendicular to this surface these swarms move
perpendicularly to the tilting angle. We describe quantitatively this motion by
a continuum model with couple stress arising from the torques produced by the
rotary motors of the amphitrichous magnetotactic bacteria. The model not only
correctly describes the change of direction of swarm motion while inverting the
tangential field but also predicts reasonable value of the torque produced by
the rotary motors
Percutaneous Ventricular Restoration (PVR) Therapy Using the Parachute Device in 100 Subjects with Ischaemic Dilated Heart Failure: One-Year Primary Endpoint Results of PARACHUTE III, a European Trial
AIMS:
This prospective, non-randomised, observational study conducted in Europe was designed in order to assess the long-term safety and efficacy of the Parachute device in ischaemic heart failure subjects as a result of left ventricle remodelling after anterior wall myocardial infarction.
METHODS AND RESULTS:
One hundred subjects with New York Heart Association Class II-IV ischaemic heart failure (HF), ejection fraction (EF) between 15% and 40%, and dilated akinetic or dyskinetic anterior-apical wall without the need to be revascularised were enrolled. The primary safety endpoint was procedural- or device-related major adverse cardiac cerebral events (MACCE). The secondary safety endpoint was the composite of mortality and morbidity. Secondary efficacy endpoints included haemodynamic measurements determined by echocardiography, LV volume indices, and assessment of functional improvement measured by a standardised six-minute walk test. Of the 100 subjects enrolled, device implantation was successful in 97 (97%) subjects. The one-year rates of the primary and secondary safety endpoints were 7% and 32.3%, respectively. The secondary endpoints, LV volume reduction (p<0.0001) and six-minute walk distance improvement (p<0.01), were achieved.
CONCLUSIONS:
The favourable outcomes observed in this high-risk population provide reassuring safety and efficacy data to support adoption of this technology as a therapeutic option for HF subjects.info:eu-repo/semantics/publishedVersio
Expert review document part 2: Methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures
Patients with coronary artery disease and diabetes need improved management: a report from the EUROASPIRE IV survey: a registry from the EuroObservational Research Programme of the European Society of Cardiology
Background: In order to influence every day clinical practice professional organisations issue management guidelines. Cross-sectional surveys are used to evaluate the implementation of such guidelines. The present survey investigated screening for glucose perturbations in people with coronary artery disease and compared patients with known and newly detected type 2 diabetes with those without diabetes in terms of their life-style and pharmacological risk factor management in relation to contemporary European guidelines. Methods: A total of 6187 patients (18–80 years) with coronary artery disease and known glycaemic status based on a self reported history of diabetes (previously known diabetes) or the results of an oral glucose tolerance test and HbA1c (no diabetes or newly diagnosed diabetes) were investigated in EUROASPIRE IV including patients in 24 European countries 2012–2013. The patients were interviewed and investigated in order to enable a comparison between their actual risk factor control with that recommended in current European management guidelines and the outcome in previously conducted surveys. Results: A total of 2846 (46%) patients had no diabetes, 1158 (19%) newly diagnosed diabetes and 2183 (35 %) previously known diabetes. The combined use of all four cardioprotective drugs in these groups was 53, 55 and 60%, respectively. A blood pressure target of 9.0% (>75 mmol/mol). Of the patients with diabetes 69% reported on low physical activity. The proportion of patients participating in cardiac rehabilitation programmes was low (≈40%) and only 27% of those with diabetes had attended diabetes schools. Compared with data from previous surveys the use of cardioprotective drugs had increased and more patients were achieving the risk factor treatment targets. Conclusions: Despite advances in patient management there is further potential to improve both the detection and management of patients with diabetes and coronary artery disease
Reperfusion therapy for ST elevation acute myocardial infarction 2010/2011: current status in 37 ESC countries
Aims Primary percutaneous coronary intervention (PPCI) is the preferred reperfusion therapy in ST-elevation myocardial infarction (STEMI). We conducted this study to evaluate the contemporary status on the use and type of reperfusion therapy in patients admitted with STEMI in the European Society of Cardiology (ESC) member countries. Methods and results A cross-sectional descriptive study based on aggregated country-level data on the use of reperfusion therapy in patients admitted with STEMI during 2010 or 2011. Thirty-seven ESC countries were able to provide data from existing national or regional registries. In countries where no such registries exist, data were based on best expert estimates. Data were collected on the use of STEMI reperfusion treatment and mortality, the numbers of cardiologists, and the availability of PPCI facilities in each country. Our survey provides a brief data summary of the degree of variation in reperfusion therapy across Europe. The number of PPCI procedures varied between countries, ranging from 23 to 884 per million inhabitants. Primary percutaneous coronary intervention and thrombolysis were the dominant reperfusion strategy in 33 and 4 countries, respectively. The mean population served by a single PPCI centre with a 24-h service 7 days a week ranged from 31 300 inhabitants per centre to 6 533 000 inhabitants per centre. Twenty-seven of the total 37 countries participated in a former survey from 2007, and major increases in PPCI utilization were observed in 13 of these countries. Conclusion Large variations in reperfusion treatment are still present across Europe. Countries in Eastern and Southern Europe reported that a substantial number of STEMI patients are not receiving any reperfusion therapy. Implementation of the best reperfusion therapy as recommended in the guidelines should be encourage
Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type
Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957
Routine revascularization with percutaneous coronary intervention in patients with coronary artery disease undergoing transcatheter aortic valve implantation - the third Nordic Aortic Valve Intervention Trial - NOTION-3
Background: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. Study design: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.</p
Effects of alirocumab on types of myocardial infarction: insights from the ODYSSEY OUTCOMES trial
AIMS: The third Universal Definition of Myocardial Infarction (MI) Task Force classified MIs into five types: Type 1, spontaneous; Type 2, related to oxygen supply/demand imbalance; Type 3, fatal without ascertainment of cardiac biomarkers; Type 4, related to percutaneous coronary intervention; and Type 5, related to coronary artery bypass surgery. Low-density lipoprotein cholesterol (LDL-C) reduction with statins and proprotein convertase subtilisin-kexin Type 9 (PCSK9) inhibitors reduces risk of MI, but less is known about effects on types of MI. ODYSSEY OUTCOMES compared the PCSK9 inhibitor alirocumab with placebo in 18 924 patients with recent acute coronary syndrome (ACS) and elevated LDL-C (>/=1.8 mmol/L) despite intensive statin therapy. In a pre-specified analysis, we assessed the effects of alirocumab on types of MI. METHODS AND RESULTS: Median follow-up was 2.8 years. Myocardial infarction types were prospectively adjudicated and classified. Of 1860 total MIs, 1223 (65.8%) were adjudicated as Type 1, 386 (20.8%) as Type 2, and 244 (13.1%) as Type 4. Few events were Type 3 (n = 2) or Type 5 (n = 5). Alirocumab reduced first MIs [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.77-0.95; P = 0.003], with reductions in both Type 1 (HR 0.87, 95% CI 0.77-0.99; P = 0.032) and Type 2 (0.77, 0.61-0.97; P = 0.025), but not Type 4 MI. CONCLUSION: After ACS, alirocumab added to intensive statin therapy favourably impacted on Type 1 and 2 MIs. The data indicate for the first time that a lipid-lowering therapy can attenuate the risk of Type 2 MI. Low-density lipoprotein cholesterol reduction below levels achievable with statins is an effective preventive strategy for both MI types
Patients with coronary artery disease and diabetes need improved management: a report from the EUROASPIRE IV survey: a registry from the EuroObservational Research Programme of the European Society of Cardiology
Background: In order to influence every day clinical practice professional organisations issue management guidelines. Cross-sectional surveys are used to evaluate the implementation of such guidelines. The present survey investigated screening for glucose perturbations in people with coronary artery disease and compared patients with known and newly detected type 2 diabetes with those without diabetes in terms of their life-style and pharmacological risk factor management in relation to contemporary European guidelines. Methods: A total of 6187 patients (18-80 years) with coronary artery disease and known glycaemic status based on a self reported history of diabetes (previously known diabetes) or the results of an oral glucose tolerance test and HbA1c (no diabetes or newly diagnosed diabetes) were investigated in EUROASPIRE IV including patients in 24 European countries 2012-2013. The patients were interviewed and investigated in order to enable a comparison between their actual risk factor control with that recommended in current European management guidelines and the outcome in previously conducted surveys. Results: A total of 2846 (46 %) patients had no diabetes, 1158 (19 %) newly diagnosed diabetes and 2183 (35 %) previously known diabetes. The combined use of all four cardioprotective drugs in these groups was 53, 55 and 60 %, respectively. A blood pressure target of <140/90 mmHg was achieved in 68, 61, 54 % and a LDL-cholesterol target of <1.8 mmol/L in 16, 18 and 28 %. Patients with newly diagnosed and previously known diabetes reached an HbA1c <7.0 % (53 mmol/mol) in 95 and 53 % and 11 % of those with previously known diabetes had an HbA1c >9.0 % (>75 mmol/mol). Of the patients with diabetes 69 % reported on low physical activity. The proportion of patients participating in cardiac rehabilitation programmes was low (approximate to 40 %) and only 27 % of those with diabetes had attended diabetes schools. Compared with data from previous surveys the use of cardioprotective drugs had increased and more patients were achieving the risk factor treatment targets. Conclusions: Despite advances in patient management there is further potential to improve both the detection and management of patients with diabetes and coronary artery disease
Expansion of the Multi-Link Frontier™ Coronary Bifurcation Stent: Micro-Computed Tomographic Assessment in Human Autopsy and Porcine Heart Samples
BACKGROUND: Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. METHODOLOGY/PRINCIPAL FINDINGS: Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm(2) vs. 12.84±1.38 mm(2), p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). CONCLUSIONS/SIGNIFICANCE: Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion
- …
