1,085 research outputs found

    Adverse events following influenza immunization reported by healthcare personnel using active surveillance based on text messages

    Get PDF
    Studies have demonstrated that healthcare personnel (HCP) have concerns about the potential side effects of trivalent inactivate influenza vaccine (IIV3).1-3 A recent metaanalysis of reasons HCP refuse IIV3 indicates the strongest predictors of vaccine acceptance are belief that the vaccine is safe and belief the vaccine does not cause the disease it is meant to prevent.

    Formation of Alewife Concretions in Polluted Onondaga Lake

    Get PDF
    The previously reported finding of alewife concretions along the shores of Onondaga Lake in Upstate New York prompted investigation of the field conditions necessary for their formation and laboratory simulation of these conditions to induce concretion formation. Onondaga Lake is shown to be calcium-polluted and continuously supersaturated with respect to CaC03• Anaerobic conditions exist in the hypolimnion in approximately eight months of every year. In controlled laboratory experiments, formation of structure-retaining alewife concretions was successful under anaerobic conditions, and was enhanced by elevated calcium concentrations. Additional chemical analyses of fresh alewives, natural concretions and laboratory-formed concretions were performed. A previously proposed mechanism for concretion formation is evaluated with respect to the presented results. The common occurrence of alewife concretions in Onondaga Lake is a manifestation of the unique polluted state of the ecosystem, combined with the invasion of the lipid-rich alewife

    A prospective cohort study comparing the reactogenicity of trivalent influenza vaccine in pregnant and non-pregnant women

    Get PDF
    Background: Influenza vaccination during pregnancy can prevent serious illness in expectant mothers and provide protection to newborns; however, historically uptake has been limited due to a number of factors, including safety concerns. Symptomatic complaints are common during pregnancy and may be mistakenly associated with reactions to trivalent influenza vaccine (TIV). To investigate this, we compared post-vaccination events self-reported by pregnant women to events reported by non-pregnant women receiving TIV. Methods: A prospective cohort of 1,086 pregnant women and 314 non-pregnant female healthcare workers (HCWs) who received TIV between March-May 2014 were followed-up seven days post-vaccination to assess local and systemic adverse events following immunisation (AEFIs). Women were surveyed by text message regarding perceived reactions to TIV. Those reporting an AEFI completed an interview by telephone or mobile phone to ascertain details. Logistic regression models adjusting for age and residence were used to compare reactions reported by pregnant women and non-pregnant HCWs. Results: Similar proportions of pregnant women and non-pregnant, female HCWs reported ≥1 reaction following vaccination with TIV (13.0% and 17.3%, respectively; OR = 1.2 [95% CI: 0.8-1.8]). Non-pregnant, female HCWs were more likely to report fever or headache compared to pregnant women (OR: 4.6 [95% CI 2.1-10.3] and OR: 2.2 [95% CI 1.0-4.6], respectively). No other significant differences in reported symptoms were observed. No serious vaccine-associated adverse events were reported, and less than 2% of each group sought medical advice for a reaction. Conclusions: We found no evidence suggesting pregnant women are more likely to report adverse events following influenza vaccination when compared to non-pregnant female HCWs of similar age, and in some cases, pregnant women reported significantly fewer adverse events. These results further support the safety of TIV administered in pregnant women

    High precision optical cavity length and width measurements using double modulation

    Get PDF
    We use doubly phase modulated light to measure both the length and the linewidth of an optical resonator with high precision. The first modulation is at RF frequencies and is set near a multiple of the free spectral range, whereas the second modulation is at audio frequencies to eliminate offset errors at DC. The light in transmission or in reflection of the optical resonator is demodulated while sweeping the RF frequency over the optical resonance. We derive expressions for the demodulated power in transmission, and show that the zero crossings of the demodulated signal in transmission serve as a precise measure of the cavity linewidth at half maximum intensity. We demonstrate the technique on two resonant cavities, with lengths 16 m and a 4 km, and achieve an absolute length accuracy as low as 70 ppb. The cavity width for the 16 m cavity was determined with an accuracy of approximately 6000 ppm. Through an analysis of the systematic errors we show that this result could be substantially improved with the reduction of technical sources of uncertainty

    Pandemic (H1N1) 2009 influenza community transmission was established in one Australian state when the virus was first identified in North America

    No full text
    BACKGROUND In mid-June 2009 the State of Victoria in Australia appeared to have the highest notification rate of pandemic (H1N1) 2009 influenza in the world. We hypothesise that this was because community transmission of pandemic influenza was already well established in Victoria at the time testing for the novel virus commenced. In contrast, this was not true for the pandemic in other parts of Australia, including Western Australia (WA). METHODS We used data from detailed case follow-up of patients with confirmed infection in Victoria and WA to demonstrate the difference in the pandemic curve in two Australian states on opposite sides of the continent. We modelled the pandemic in both states, using a susceptible-infected-removed model with Bayesian inference accounting for imported cases. RESULTS Epidemic transmission occurred earlier in Victoria and later in WA. Only 5% of the first 100 Victorian cases were not locally acquired and three of these were brothers in one family. By contrast, 53% of the first 102 cases in WA were associated with importation from Victoria. Using plausible model input data, estimation of the effective reproductive number for the Victorian epidemic required us to invoke an earlier date for commencement of transmission to explain the observed data. This was not required in modelling the epidemic in WA. CONCLUSION Strong circumstantial evidence, supported by modelling, suggests community transmission of pandemic influenza was well established in Victoria, but not in WA, at the time testing for the novel virus commenced in Australia. The virus is likely to have entered Victoria and already become established around the time it was first identified in the US and Mexico

    Respiratory illness in a piggery associated with the first identified outbreak of swine influenza in Australia: Assessing the risk to human health and zoonotic potential

    Get PDF
    Australia was previously believed to be free of enzootic swine influenza viruses due strict quarantine practices and use of biosecure breeding facilities. The first proven Australian outbreak of swine influenza occurred in Western Australian in 2012, revealing an unrecognized zoonotic risk, and a potential future pandemic threat. A public health investigation was undertaken to determine whether zoonotic infections had occurred and to reduce the risk of further transmission between humans and swine. A program of monitoring, testing, treatment, and vaccination was commenced, and a serosurvey of workers was also undertaken. No acute infections with the swine influenza viruses were detected. Serosurvey results were difficult to interpret due to previous influenza infections and past and current vaccinations. However, several workers had elevated haemagglutination inhibition (HI) antibody levels to the swine influenza viruses that could not be attributed to vaccination or infection with contemporaneous seasonal influenza A viruses. However, we lacked a suitable control population, so this was inconclusive. The experience was valuable in developing better protocols for managing outbreaks at the human–animal interface. Strict adherence to biosecurity practices, and ongoing monitoring of swine and their human contacts is important to mitigate pandemic risk. Strain specific serological assays would greatly assist in identifying zoonotic transmission

    Environmental influences on the LIGO gravitational wave detectors during the 6th science run

    Get PDF
    We describe the influence of environmental noise on Laser Interferometric Gravitational-Wave Observatory (LIGO) detectors in the sixth science run, from July 2009 to October 2010. We show results from experimental investigations testing the coupling level and mechanisms for acoustic, electromagnetic/magnetic and seismic noise to the instruments. We argue the sensors\u27 importance for vetoes of false positive detections, report estimates of the noise sources\u27 contributions to the detector background, and discuss the ways in which environmental coupling should be reduced in the LIGO upgrade, Advanced LIGO

    LIGO’s quantum response to squeezed states

    Get PDF
    Gravitational wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the Universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector’s quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing’s simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and—for the first time—give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors

    Reducing scattered light in LIGO\u27s third observing run

    Get PDF
    Noise due to scattered light has been a frequent disturbance in the advanced LIGO gravitational wave detectors, hindering the detection of gravitational waves. The non stationary scatter noise caused by low frequency motion can be recognized as arches in the time-frequency plane of the gravitational wave channel. In this paper, we characterize the scattering noise for LIGO and Virgo\u27s third observing run O3 from April, 2019 to March, 2020. We find at least two different populations of scattering noise and we investigate the multiple origins of one of them as well as its mitigation. We find that relative motion between two specific surfaces is strongly correlated with the presence of scattered light and we implement a technique to reduce this motion. We also present an algorithm using a witness channel to identify the times this noise can be present in the detecto

    Quantum correlations between the light and kilogram-mass mirrors of LIGO

    Get PDF
    Measurement of minuscule forces and displacements with ever greater precision encounters a limit imposed by a pillar of quantum mechanics: the Heisenberg uncertainty principle. A limit to the precision with which the position of an object can be measured continuously is known as the standard quantum limit (SQL) [1–4]. When light is used as the probe, the SQL arises from the balance between the uncertainties of photon radiation pressure imposed on the object and of the photon number in the photoelectric detection. The only possibility surpassing the SQL is via correlations within the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light it reflects [5]. Here, we experimentally prove the theoretical prediction that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). Our measurements show that the quantum mechanical uncertainties in the phases of the 200 kW laser beams and in the positions of the 40 kg mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty a factor of 1.4 (3 dB) below the SQL. We anticipate that quantum correlations will not only improve gravitational wave (GW) observatories but all types of measurements in future
    • …
    corecore