193 research outputs found

    Molecular Dynamics Simulations of Dynamic Force Microscopy: Applications to the Si(111)-7x7 Surface

    Full text link
    Molecular dynamics simulations have been performed to understand true atomic resolution, which has been observed on the Si(111)-7×\times7 surface by dynamic force microscopy in ultra high vacuum(UHV). Stable atomic-scale contrast is reproduced in simulations at constant mean height above a critical tip-sample separation when monitoring the interaction force between tip and sample. Missing or additional adatoms can be recognized in such scans, although they are less well resolved than native adatoms. The resonance frequency shift, as well as arbitrary scans, e.g. at constant force can be computed from a series of force-distance characteristics. By means of dynamic simulations we show how energy losses induced by interaction with an oscillating tip can be monitored and that they occur even in the non-contact range.Comment: 5 pages, 5 figures, accepted publication in Applied Surface Scienc

    The Impact of Eruption Source Parameter Uncertainties on Ash Dispersion Forecasts During Explosive Volcanic Eruptions

    Get PDF
    Volcanic ash in the atmosphere is a hazard to aviation. To predict which areas of airspace are most likely to be affected by the presence of ash, Volcanic Ash Advisory Centers (VAACs) use observations and atmospheric dispersion models. These models are initialized with, among other parameters, a mass eruption rate (MER), which quantifies the emission rate into the atmosphere at the source. This influences the predicted spatial–temporal evolution and concentration of the ash cloud. Different models are available to estimate MER from the volcanic plume height and some models also include the weather conditions (e.g., wind speed). The REFIR software tool uses time‐series of plume height estimated from observations and weather data to provide estimates of MER through time. Here we present an updated version of REFIR that can now be used also to calculate MER for past eruptions and produce output parameters in a format suitable for use with the NAME dispersion model (UK Met Office—London VAAC). We also investigate how uncertainty in input parameters is propagated through to dispersion model output. Our results show that a +/−1 km uncertainty on a 6 km high plume can result in the affected area ranging by a factor of three between the minimum and maximum estimates. Additionally, we show that using wind‐affected plume models results in affected areas that are five times larger than using no‐wind‐affected models. This demonstrates the sensitivity of MER to the type of plume model chosen (no‐wind‐ vs. wind‐affected)

    Application of a novel prioritisation strategy using non-target screening for evaluation of temporal trends (1969-2017) of contaminants of emerging concern (CECs) in archived lynx muscle tissue samples

    Get PDF
    Most environmental monitoring studies of contaminants of emerging concern (CECs) focus on aquatic species and target specific classes of CECs. Even with wide-scope target screening methods, relevant CECs may be missed. In this study, non-target screening (NTS) was used for tentative identification of potential CECs in muscle tissue of the terrestrial top predator Eurasian lynx (Lynx lynx). Temporal trend analysis was applied as a prioritisation tool for archived samples, using univariate statistical tests (Mann-Kendall and Spearman rank). Pooled lynx muscle tissue collected from 1969 to 2017 was analysed with an eight-point time series using a previously validated screening workflow. Following peak detection, peak alignment, and blank subtraction, 12,941 features were considered for statistical analysis. Prioritisation by time-trend analysis detected 104 and 61 features with statistically significant increasing and decreasing trends, respectively. Following probable molecular formula assignment and elucidation with MetFrag, two compounds with increasing trends, and one with a decreasing trend, were tentatively identified. These results show that, despite low expected concentration levels and high matrix effects in terrestrial species, it is possible to prioritise CECs in archived lynx samples using NTS and univariate statistical approaches

    The Role of Nonlinear Dynamics in Quantitative Atomic Force Microscopy

    Full text link
    Various methods of force measurement with the Atomic Force Microscope (AFM) are compared for their ability to accurately determine the tip-surface force from analysis of the nonlinear cantilever motion. It is explained how intermodulation, or the frequency mixing of multiple drive tones by the nonlinear tip-surface force, can be used to concentrate the nonlinear motion in a narrow band of frequency near the cantilevers fundamental resonance, where accuracy and sensitivity of force measurement are greatest. Two different methods for reconstructing tip-surface forces from intermodulation spectra are explained. The reconstruction of both conservative and dissipative tip-surface interactions from intermodulation spectra are demonstrated on simulated data.Comment: 25 pages (preprint, double space) 7 figure

    Ductus venosus blood flow velocity characteristics of fetuses with single umbilical artery

    Get PDF
    Objectives: Sonographic Doppler evaluation of the fetal ductus venosus has been proved to be useful in the evaluation of fetal cardiac function. The aim of this study was to investigate the ductus venosus blood flow profile in fetuses with single umbilical artery and to correlate it with the umbilical cord morphology. Methods: Fetuses at > 20 weeks' gestation with single umbilical artery who were otherwise healthy were consecutively enrolled into the study. The sonographic examination included evaluation of the following Doppler parameters: umbilical artery resistance index, maximum blood flow velocity of the ductus venosus during ventricular systole (S-peak) and atrial contraction (A-wave), ductus venosus time-averaged maximum velocity (TAMXV), and pulsatility index for veins (PIV). The cross-sectional area of the umbilical cord and its vessels were measured in all cases. The Doppler and morphometric values obtained were plotted on reference ranges. Results: A total of 88 fetuses with single umbilical artery were scanned during the study period. Of these 52 met the inclusion criteria. The S-peak velocity, A-wave velocity, and TAMXV were below the 5th centile for gestational age in 57.7%, 59.6%, and 57.7% of cases, respectively. The PIV was within the normal range in 80.1% of cases. The umbilical vein cross-sectional area of fetuses with single umbilical artery was above the 95th centile for gestational age in 34.6% cases. Conclusions: The ductus venosus blood flow pattern is different in fetuses with single umbilical artery from that in those with a three-vessel cord. This difference may be caused in part by the particular morphology of umbilical cords with a single artery. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd

    Management of Hyperglycemia in Hospitalized Patients Receiving Parenteral Nutrition.

    Get PDF
    Almost half of inpatients on parenteral nutrition experience hyperglycemia, which increases the risk of complications and mortality. The blood glucose target for hospitalized patients on parenteral nutrition is 7.8 to 10.0 mmol/L (140 to 180 mg/dL). For patients with diabetes, the same parenteral nutrition formulae as for patients without diabetes can be used, as long as blood glucose levels can be adequately controlled using insulin. Insulin can be delivered via the subcutaneous or intravenous route or, alternatively, added to parenteral nutrition admixtures. Combining parenteral with enteral and oral nutrition can improve glycemic control in patients with sufficient endogenous insulin stores. Intravenous insulin infusion is the preferred route of insulin delivery in critical care as doses can be rapidly adjusted to altered requirements. For stable patients, insulin can be added directly to the parenteral nutrition bag. If parenteral nutrition is infused continuously over 24 hours, the subcutaneous injection of a long-acting insulin combined with correctional bolus insulin may be adequate. The aim of this review is to give an overview of the management of parenteral nutrition-associated hyperglycemia in inpatients with diabetes

    Interaction imaging with amplitude-dependence force spectroscopy

    Full text link
    Knowledge of surface forces is the key to understanding a large number of processes in fields ranging from physics to material science and biology. The most common method to study surfaces is dynamic atomic force microscopy (AFM). Dynamic AFM has been enormously successful in imaging surface topography, even to atomic resolution, but the force between the AFM tip and the surface remains unknown during imaging. Here, we present a new approach that combines high accuracy force measurements and high resolution scanning. The method, called amplitude-dependence force spectroscopy (ADFS) is based on the amplitude-dependence of the cantilever's response near resonance and allows for separate determination of both conservative and dissipative tip-surface interactions. We use ADFS to quantitatively study and map the nano-mechanical interaction between the AFM tip and heterogeneous polymer surfaces. ADFS is compatible with commercial atomic force microscopes and we anticipate its wide-spread use in taking AFM toward quantitative microscopy

    Probing the shape of atoms in real space

    Get PDF
    The structure of single atoms in real space is investigated by scanning tunneling microscopy. Very high resolution is possible by a dramatic reduction of the tip-sample distance. The instabilities which are normally encountered when using small tip-sample distances are avoided by oscillating the tip of the scanning tunneling microscope vertically with respect to the sample. The surface atoms of Si(111)-(7 x 7) with their well-known electronic configuration are used to image individual samarium, cobalt, iron and silicon atoms. The resulting images resemble the charge density corresponding to 4f, 3d and 3p atomic orbitals.Comment: Submitted to Phys. Rev. B, 17 pages, 7 figure

    Distance dependence of force and dissipation in non-contact atomic force microscopy on Cu(100) and Al(111)

    Full text link
    The dynamic characteristics of a tip oscillating in the nc-AFM mode in close vicinity to a Cu(100)-surface are investigated by means of phase variation experiments in the constant amplitude mode. The change of the quality factor upon approaching the surface deduced from both frequency shift and excitation versus phase curves yield to consistent values. The optimum phase is found to be independent of distance. The dependence of the quality factor on distance is related to 'true' damping, because artefacts related to phase misadjustment can be excluded. The experimental results, as well as on-resonance measurements at different bias voltages on an Al(111) surface, are compared to Joule dissipation and to a model of dissipation in which long-range forces lead to viscoelastic deformations

    An all silicon quantum computer

    Get PDF
    A solid-state implementation of a quantum computer composed entirely of silicon is proposed. Qubits are Si-29 nuclear spins arranged as chains in a Si-28 (spin-0) matrix with Larmor frequencies separated by a large magnetic field gradient. No impurity dopants or electrical contacts are needed. Initialization is accomplished by optical pumping, algorithmic cooling, and pseudo-pure state techniques. Magnetic resonance force microscopy is used for readout. This proposal takes advantage of many of the successful aspects of solution NMR quantum computation, including ensemble measurement, RF control, and long decoherence times, but it allows for more qubits and improved initialization.Comment: ReVTeX 4, 5 pages, 2 figure
    corecore