13 research outputs found

    Radiation-induced changes in levels of selected proteins in peripheral blood serum of breast cancer patients as a potential triage biodosimeter for large-scale radiological emergencies

    No full text
    The threat of a large scale radiological emergency, where thousands of people may require fast biological dosimetry for the purpose of triage, makes it necessary to search for new, high throughput biological dosimeters. The authors tested an assay based on the quantitative analysis of selected proteins in peripheral blood serum. They were particularly interested in testing proteins that are specific to irradiation of skin, as these can be used in cases of partial body exposure. Candidate proteins were identified in an earlier study with mice, where skin of the animals was exposed to different doses of radiation and global expression of serum proteins was analyzed. Eight proteins were found, the expression of which showed a consistent dose-response relationship. Human analogues of these proteins were identified, and their expression was measured in peripheral blood serum of 16 breast cancer patients undergoing external beam radiotherapy. The proteins were Apolipoprotein E; Apolipoprotein H; Complement protein 7; Prothrombinase; Pantothenate Kinase 4; Alpha-2-macroglobulin; Fetuin B and Alpha-1-Anti-Chymotrypsin. Measurements were carried out in blood samples collected prior to exposure (control), on the day after one fraction (2 Gy), on the day after five fractions (10 Gy), on the day after 10 fractions (20 Gy), and 1 mo after 23-25 fractions (total dose of 46-50 Gy). Multivariate analysis was carried out, and a multinomial logistic regression model was built. The results. © 2014 Health Physics Society

    Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents

    No full text
    In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident

    Inter- and intra-laboratory comparison of a multibiodosimetric approach to triage in a simulated, large scale radiation emergency

    No full text
    International audiencePurpose The European Union's Seventh Framework Programme-funded project 'Multi-disciplinary biodosimetric tools to manage high scale radiological casualties' (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals. Materials and methods Three biological dosimetry tools-the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays-were tested, in addition to provision of the triage status results (low exposure 2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included. Results The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here. Conclusions The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective. © 2014 Informa UK, Ltd
    corecore