27 research outputs found

    A new HPLC method for simultaneously measuring chloride, sugars, organic acids and alcohols in food samples

    Get PDF
    This paper introduces an original, rapid, efficient and reliable HPLC method for the accurate and simultaneous quantification (g/L) of chloride in samples containing sugars, organic acids and alcohols. Separation was achieved using a HI-Plex H column at 35oC, with H2SO4 (0.005 N) as the mobile phase at a flow rate of 0.4 mL/min. The column effluent was monitored by a Refractive Index (RI) detector. A linear response was achieved over NaCl concentrations of 0.25 – 2.5 g/L and 5 – 40 g/L. The analytical method inter- and intra-run accuracy and precision were better than ±10.0%. Investigating the mechanism of detection using different chloride and sodium s reviled that this method can be used for determining the total concentration of chloride salts when in suspension. This method was successfully applied to 15 samples of commercial food products and the salt content obtained from this method was compared with 3 other methods for salt determination. The (HI-Plex H) column was designed for determining the concentrations of sugars, organic acids and alcohols when in solution. Hence, application of our new methodology would allow the determination of sugars, alcohols and organic acids in samples derived from seawater-based fermentation media as well as samples from salty food and dairy products

    Screening of antioxidant properties of the apple juice using the front-face synchronous fluorescence and chemometrics

    Get PDF
    Fluorescence spectroscopy is gaining increasing attention in food analysis due to its higher sensitivity and selectivity as compared to other spectroscopic techniques. Synchronous scanning fluorescence technique is particularly useful in studies of multi-fluorophoric food samples, providing a further improvement of selectivity by reduction in the spectral overlapping and suppressing light-scattering interferences. Presently, we study the feasibility of the prediction of the total phenolics, flavonoids, and antioxidant capacity using front-face synchronous fluorescence spectra of apple juices. Commercial apple juices from different product ranges were studied. Principal component analysis (PCA) applied to the unfolded synchronous fluorescence spectra was used to compare the fluorescence of the entire sample set. The regression analysis was performed using partial least squares (PLS1 and PLS2) methods on the unfolded total synchronous and on the single-offset synchronous fluorescence spectra. The best calibration models for all of the studied parameters were obtained using the PLS1 method for the single-offset synchronous spectra. The models for the prediction of the total flavonoid content had the best performance; the optimal model was obtained for the analysis of the synchronous fluorescence spectra at Delta lambda = 110 nm (R (2) = 0.870, residual predictive deviation (RPD) = 2.7). The optimal calibration models for the prediction of the total phenolic content (Delta lambda = 80 nm, R (2) = 0.766, RPD = 2.0) and the total antioxidant capacity (Delta lambda = 70 nm, R (2) = 0.787, RPD = 2.1) had only an approximate predictive ability. These results demonstrate that synchronous fluorescence could be a useful tool in fast semi-quantitative screening for the antioxidant properties of the apple juices.info:eu-repo/semantics/publishedVersio

    Determination of Anthracene on Ag-Au Alloy Nanoparticles/Overoxidized-Polypyrrole Composite Modified Glassy Carbon Electrodes

    Get PDF
    A novel electrochemical sensor for the detection of anthracene was prepared by modifying a glassy carbon electrode (GCE) with over-oxidized polypyrrole (PPyox) and Ag-Au (1:3) bimetallic nanoparticles (Ag-AuNPs). The composite electrode (PPyox/Ag-AuNPs/GCE) was prepared by potentiodynamic polymerization of pyrrole on GCE followed by its overoxidation in 0.1 M NaOH. Ag-Au bimetallic nanoparticles were chemically prepared by the reduction of AgNO3 and HAuCl4 using C6H5O7Na3 as the reducing agent as well as the capping agent and then immobilized on the surface of the PPyox/GCE. The nanoparticles were characterized by UV-visible spectroscopy technique which confirmed the homogeneous formation of the bimetallic alloy nanoparticles. Transmission electron microscopy showed that the synthesized bimetallic nanoparticles were in the range of 20–50 nm. The electrochemical behaviour of anthracene at the PPyox/Ag-AuNPs/GCE with Ag: Au atomic ratio 25:75 (1:3) exhibited a higher electrocatalytic effect compared to that observed when GCE was modified with each constituent of the composite (i.e., PPyox, Ag-AuNPs) and bare GCE. A linear relationship between anodic current and anthracene concentration was attained over the range of 3.0 × 10−6 to 3.56 × 10−4 M with a detection limit of 1.69 × 10−7 M. The proposed method was simple, less time consuming and showed a high sensitivity

    Modeling of inner filter effect in synchronous spectrofluorimetry by using partial least squares

    No full text
    This paper deals with a very common problem on spectrofluorimetry: the inner-filter effect. This limitation has made spectrofluorimetry into a disadvantageous technique for the quantification of individual compounds in complex mixtures, however, a lot of papers have quantified compounds as fluorene in mixtures where other Polycyclic Aromatic Hydrocarbons (PAHs) absorb part of the energy emitted by fluorene without taking account this limitation. The inner-effect filter for fluorene is easily detectable in spectrofluorimetric measurements in mixtures where there are compounds, such as benzo(k)fluoranthene, indeno(1,2,3-cd)pyrene and pyrene. The application of methods, such as Multiple Linear Regression (MLR) to the quantification of fluorene in mixtures containing compounds capable to quench its signal, provides high errors in the analytical results. This point is carefully treated in our paper. The precise and accurate quantification of fluorene in presence of benzo(k)fluoranthene, indene(1,2,3-cd)pyrene and pyrene, was achieved by constant-wavelength synchronous fluorimetry in combination with Partial Least Squares (PLS) calibration