720 research outputs found

    Usefulness of routine pairing of anaerobic with aerobic blood culture bottles and decision making on antimicrobial therapy

    Get PDF
    ObjectivesTo evaluate the growth concordance in paired aerobic/anaerobic sets, and the impact of the anaerobic growth on patients' antimicrobial management.MethodThis is a prospective multicenter study which was conducted in three hospitals, with total beds of 750 beds and 52 ICU beds. Prospectively, laboratory blood cultures logbooks were daily reviewed and patients from whom blood cultures were ordered were followed, their chart were reviewed. Entries on antimicrobial therapeutic changes were noted for all paired sets. Clinicians were blinded to the study, though they were informed about culture results via the usual work protocol in each hospital.ResultsCollected Blood culture sets totaled 2492; 172 single sets were excluded, and 1160 paired sets were analyzed. 1046 were concordant; 79 sets had bacterial growth and 967 sets had no bacterial growth. 114 sets were discordant; 97 in aerobic bottles, 13 in anaerobic, and 4 in both.The proportion of agreement for the concordant paired growth sets was 90.2%.  The composite proportion of agreement for sets with any growth (N = 193, composite proportion of agreement = 56%, 95% C.I., 34% - 48%). Cohen kappa composite agreement, measured for the total analyzed paired-sets (N = 1160, K = .52, SE = .038. 95% C.I., .447 - .595). The odds of modifying antimicrobial regimen were for total and subgroups intent to treat odds, based on paired sets showed that one modification took place in one anaerobic growth set (N = 1160, Odds = 0.0008), the odds for all sets with any growth (N = 193, odds = .005), and based on any anaerobic sets (79 concordant, 13 anaerobic, and 4 discordant) with bacterial growth (N = 96: odds = 0.010).ConclusionThe study demonstrates that the proportion of agreement among paired sets were high, and needless to include anaerobic sets in routine blood culture collection. Also the decision-making of anti-infective treatment on patients based on anaerobic blood culture growth was not evident

    Breast-cancer detection using blood-based infrared molecular fingerprints

    Get PDF
    BACKGROUND Breast cancer screening is currently predominantly based on mammography, tainted with the occurrence of both false positivity and false negativity, urging for innovative strategies, as effective detection of early-stage breast cancer bears the potential to reduce mortality. Here we report the results of a prospective pilot study on breast cancer detection using blood plasma analyzed by Fourier-transform infrared (FTIR) spectroscopy - a rapid, cost-effective technique with minimal sample volume requirements and potential to aid biomedical diagnostics. FTIR has the capacity to probe health phenotypes via the investigation of the full repertoire of molecular species within a sample at once, within a single measurement in a high-throughput manner. In this study, we take advantage of cross-molecular fingerprinting to probe for breast cancer detection. METHODS We compare two groups: 26 patients diagnosed with breast cancer to a same-sized group of age-matched healthy, asymptomatic female participants. Training with support-vector machines (SVM), we derive classification models that we test in a repeated 10-fold cross-validation over 10 times. In addition, we investigate spectral information responsible for BC identification using statistical significance testing. RESULTS Our models to detect breast cancer achieve an average overall performance of 0.79 in terms of area under the curve (AUC) of the receiver operating characteristic (ROC). In addition, we uncover a relationship between the effect size of the measured infrared fingerprints and the tumor progression. CONCLUSION This pilot study provides the foundation for further extending and evaluating blood-based infrared probing approach as a possible cross-molecular fingerprinting modality to tackle breast cancer detection and thus possibly contribute to the future of cancer screening

    Splitting Arabic Texts into Elementary Discourse Units

    Get PDF
    International audienceIn this article, we propose the first work that investigates the feasibility of Arabic discourse segmentation into elementary discourse units within the segmented discourse representation theory framework. We first describe our annotation scheme that defines a set of principles to guide the segmentation process. Two corpora have been annotated according to this scheme: elementary school textbooks and newspaper documents extracted from the syntactically annotated Arabic Treebank. Then, we propose a multiclass supervised learning approach that predicts nested units. Our approach uses a combination of punctuation, morphological, lexical, and shallow syntactic features. We investigate how each feature contributes to the learning process. We show that an extensive morphological analysis is crucial to achieve good results in both corpora. In addition, we show that adding chunks does not boost the performance of our system

    Flocked nasal swab versus nasopharyngeal aspirate for detection of respiratory tract viruses in immunocompromised adults: a matched comparative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Several studies have compared nasal swabs to the more invasive nasopharyngeal aspirate (NPA) for detection of respiratory viruses. Mostly, the comparisons have been performed on immunocompetent children with upper respiratory tract symptoms. The results range from a relatively poor sensitivity for the swabs to an even higher sensitivity than for the NPA. We aimed to investigate the sensitivity of a flocked nasal swab (fNS) on immunocompromised adults with febrile neutropenia.</p> <p>Methods</p> <p>During 16 months, adults with a hematological disorder presenting with febrile neutropenia were enrolled in the study. Paired samples of the fNS and NPA were collected in the outer part of the nasal cavity and the nasopharynx, respectively. The samples were analyzed regarding a panel of 15 respiratory viruses by means of quantitative polymerase chain reaction. Furthermore, as an indirect measure of cell yield by either method, the copy number of the human beta actin gene was also determined. Cohen's kappa was calculated as a measure of agreement of the results obtained from either method. Wilcoxon signed-rank test was used for comparison of cell yield.</p> <p>Results</p> <p>A total of 98 paired samples from a total of 89 patients were collected. Twenty of the pairs had virus detected in at least one of the specimens; 11 in both, 7 in NPA only, and 2 in fNS only. For the fNS, the overall sensitivity for any virus and for rhinovirus only was 65% and 78%, respectively. NPA was significantly superior to the fNS in collecting epithelial cells.</p> <p>Conclusion</p> <p>We found the overall sensitivity of 65% to be too low to replace NPA with this sampling technique in this patient category.</p

    Self-Collected Mid-Turbinate Swabs for the Detection of Respiratory Viruses in Adults with Acute Respiratory Illnesses

    Get PDF
    BACKGROUND: The gold standard for respiratory virus testing is a nasopharyngeal (NP) swab, which is collected by a healthcare worker. Midturbinate (MT) swabs are an alternative due to their ease of collection and possible self-collection by patients. The objective of this study was to compare the respiratory virus isolation of flocked MT swabs compared to flocked NP swabs. METHODS: Beginning in October 2008, healthy adults aged 18 to 69 years were recruited into a cohort and followed up for symptoms of influenza. They were asked to have NP and MT swabs taken as soon as possible after the onset of a fever or two or more respiratory symptoms with an acute onset. The swabs were tested for viral respiratory infections using Seeplex® RV12 multiplex PCR detection kit. Seventy six pairs of simultaneous NP and MT swabs were collected from 38 symptomatic subjects. Twenty nine (38%) of these pairs were positive by either NP or MT swabs or both. Sixty nine (91%) of the pair results were concordant. Two samples (3%) for hCV OC43/HKU1 and 1 sample (1%) for rhinovirus A/B were positive by NP but negative by MT. One sample each for hCV 229E/NL63, hCV OC43/HKU1, respiratory syncytial virus A, and influenza B were positive by MT but negative by NP. CONCLUSIONS: Flocked MT swabs are sensitive for the diagnosis of multiple respiratory viruses. Given the ease of MT collection and similar results between the two swabs, it is likely that MT swabs should be the preferred method of respiratory cell collection for outpatient studies. In light of this data, larger studies should be performed to ensure that this still holds true and data should also be collected on the patient preference of collection methods

    Swabbing for respiratory viral infections in older patients: a comparison of rayon and nylon flocked swabs

    Get PDF
    The purpose of this study was to compare the sampling efficacy of rayon swabs and nylon flocked swabs, and of oropharyngeal and nasopharyngeal specimens for the detection of respiratory viruses in elderly patients. Samples were obtained from patients 60 years of age or above who were newly admitted to Sorlandet Hospital Arendal, Norway. The patients were interviewed for current symptoms of a respiratory tract infection. Using rayon swabs and nylon flocked swabs, comparable sets of mucosal samples were harvested from the nasopharynx and the oropharynx. The samples were analysed using real-time polymerase chain reaction (PCR) methods. A total of 223 patients (mean age 74.9 years, standard deviation [SD] 9.0 years) were swabbed and a virus was recovered from 11% of the symptomatic patients. Regardless of the sampling site, a calculated 4.8 times higher viral load (95% confidence interval [CI] 1.3–17, p = 0.017) was obtained using the nylon flocked swabs as compared to the rayon swabs. Also, regardless of the type of swab, a calculated 19 times higher viral load was found in the samples from the nasopharynx as compared to the oropharynx (95% CI 5.4–67.4, p < 0.001). When swabbing for respiratory viruses in elderly patients, nasopharyngeal rather than oropharyngeal samples should be obtained. Nylon flocked swabs appear to be more efficient than rayon swabs

    Selective Immune Suppression Using Interleukin-6 Receptor Inhibitors for Management of Immune-related Adverse Events

    Get PDF
    BACKGROUND: Management of immune-related adverse events (irAEs) is important as they cause treatment interruption or discontinuation, more often seen with combination immune checkpoint inhibitor (ICI) therapy. Here, we retrospectively evaluated the safety and effectiveness of anti-interleukin-6 receptor (anti-IL-6R) as therapy for irAEs. METHODS: We performed a retrospective multicenter study evaluating patients diagnosed with de novo irAEs or flare of pre-existing autoimmune disease following ICI and were treated with anti-IL-6R. Our objectives were to assess the improvement of irAEs as well as the overall tumor response rate (ORR) before and after anti-IL-6R treatment. RESULTS: We identified a total of 92 patients who received therapeutic anti-IL-6R antibodies (tocilizumab or sarilumab). Median age was 61 years, 63% were men, 69% received anti-programmed cell death protein-1 (PD-1) antibodies alone, and 26% patients were treated with the combination of anti-cytotoxic T lymphocyte antigen-4 and anti-PD-1 antibodies. Cancer types were primarily melanoma (46%), genitourinary cancer (35%), and lung cancer (8%). Indications for using anti-IL-6R antibodies included inflammatory arthritis (73%), hepatitis/cholangitis (7%), myositis/myocarditis/myasthenia gravis (5%), polymyalgia rheumatica (4%), and one patient each with autoimmune scleroderma, nephritis, colitis, pneumonitis and central nervous system vasculitis. Notably, 88% of patients had received corticosteroids, and 36% received other disease-modifying antirheumatic drugs (DMARDs) as first-line therapies, but without adequate improvement. After initiation of anti-IL-6R (as first-line or post-corticosteroids and DMARDs), 73% of patients showed resolution or change to ≤grade 1 of irAEs after a median of 2.0 months from initiation of anti-IL-6R therapy. Six patients (7%) stopped anti-IL-6R due to adverse events. Of 70 evaluable patients by RECIST (Response Evaluation Criteria in Solid Tumors) V.1.1 criteria; the ORR was 66% prior versus 66% after anti-IL-6R (95% CI, 54% to 77%), with 8% higher complete response rate. Of 34 evaluable patients with melanoma, the ORR was 56% prior and increased to 68% after anti-IL-6R (p=0.04). CONCLUSION: Targeting IL-6R could be an effective approach to treat several irAE types without hindering antitumor immunity. This study supports ongoing clinical trials evaluating the safety and efficacy of tocilizumab (anti-IL-6R antibody) in combination with ICIs (NCT04940299, NCT03999749)

    Selective Immune Suppression Using Interleukin-6 Receptor Inhibitors for Management of Immune-Related Adverse Events

    Get PDF
    BACKGROUND: Management of immune-related adverse events (irAEs) is important as they cause treatment interruption or discontinuation, more often seen with combination immune checkpoint inhibitor (ICI) therapy. Here, we retrospectively evaluated the safety and effectiveness of anti-interleukin-6 receptor (anti-IL-6R) as therapy for irAEs. METHODS: We performed a retrospective multicenter study evaluating patients diagnosed with de novo irAEs or flare of pre-existing autoimmune disease following ICI and were treated with anti-IL-6R. Our objectives were to assess the improvement of irAEs as well as the overall tumor response rate (ORR) before and after anti-IL-6R treatment. RESULTS: We identified a total of 92 patients who received therapeutic anti-IL-6R antibodies (tocilizumab or sarilumab). Median age was 61 years, 63% were men, 69% received anti-programmed cell death protein-1 (PD-1) antibodies alone, and 26% patients were treated with the combination of anti-cytotoxic T lymphocyte antigen-4 and anti-PD-1 antibodies. Cancer types were primarily melanoma (46%), genitourinary cancer (35%), and lung cancer (8%). Indications for using anti-IL-6R antibodies included inflammatory arthritis (73%), hepatitis/cholangitis (7%), myositis/myocarditis/myasthenia gravis (5%), polymyalgia rheumatica (4%), and one patient each with autoimmune scleroderma, nephritis, colitis, pneumonitis and central nervous system vasculitis. Notably, 88% of patients had received corticosteroids, and 36% received other disease-modifying antirheumatic drugs (DMARDs) as first-line therapies, but without adequate improvement. After initiation of anti-IL-6R (as first-line or post-corticosteroids and DMARDs), 73% of patients showed resolution or change to ≤grade 1 of irAEs after a median of 2.0 months from initiation of anti-IL-6R therapy. Six patients (7%) stopped anti-IL-6R due to adverse events. Of 70 evaluable patients by RECIST (Response Evaluation Criteria in Solid Tumors) V.1.1 criteria; the ORR was 66% prior versus 66% after anti-IL-6R (95% CI, 54% to 77%), with 8% higher complete response rate. Of 34 evaluable patients with melanoma, the ORR was 56% prior and increased to 68% after anti-IL-6R (p=0.04). CONCLUSION: Targeting IL-6R could be an effective approach to treat several irAE types without hindering antitumor immunity. This study supports ongoing clinical trials evaluating the safety and efficacy of tocilizumab (anti-IL-6R antibody) in combination with ICIs (NCT04940299, NCT03999749)

    Detection of multiple respiratory pathogens during primary respiratory infection: nasal swab versus nasopharyngeal aspirate using real-time polymerase chain reaction

    Get PDF
    In this study, we present the multiple detection of respiratory viruses in infants during primary respiratory illness, investigate the sensitivity of nasal swabs and nasopharyngeal aspirates, and assess whether patient characteristics and viral load played a role in the sensitivity. Healthy infants were included at signs of first respiratory tract infection. Paired nasopharyngeal aspirates and nasal swabs were collected. Real-time polymerase chain reaction (PCR) was carried out for 11 respiratory pathogens. Paired nasopharyngeal aspirates and nasal swabs were collected in 98 infants. Rhinovirus (n = 67) and respiratory syncytial virus (n = 39) were the most frequently detected. Co-infection occurred in 48% (n = 45) of the infants. The sensitivity of the nasal swab was lower than the nasopharyngeal aspirate, in particular, for respiratory syncytial virus (51% vs. 100%) and rhinovirus (75% vs. 97%). The sensitivity of the nasal swab was strongly determined by the cycle threshold (CT) value (p < 0.001). The sensitivity of the swab for respiratory syncytial virus, but not rhinovirus, was 100% in children with severe symptoms (score ≥11). It is concluded that, for community-based studies and surveillance purposes, the nasal swab can be used, though the sensitivity is lower than the aspirate, in particular, for the detection of mild cases of respiratory syncytial virus (RSV) infection
    • …
    corecore