2,652 research outputs found

    Hexa-μ-chlorido-hexa­chlorido(η6-hexa­methyl­benzene)trialuminium(III)lanthanum(III) benzene solvate

    Get PDF
    In the title compound, [Al3LaCl12(C12H18)]·C6H6, all mol­ecules are located on a mirror plane. Three chloridoaluminate groups and a hexa­methyl­benzene mol­ecule are bound to the central lanthanum(III) ion, forming a distorted penta­gonal bipyramid with the η6-coordinated arene located at the apical position. The hexa­methyl­benzene ligand disordered between two orientations in a 1:1 ratio is also involved in parallel-slipped π–π stacking inter­molecular inter­actions with a benzene solvent mol­ecule [centroid–centroid distance 3.612 (4) Å]

    Electronic structure and magnetic properties of the spin-1/2 Heisenberg system CuSe2O5

    Get PDF
    A microscopic magnetic model for the spin-1/2 Heisenberg chain compound CuSe2O5 is developed based on the results of a joint experimental and theoretical study. Magnetic susceptibility and specific heat data give evidence for quasi-1D magnetism with leading antiferromagnetic (AFM) couplings and an AFM ordering temperature of 17 K. For microscopic insight, full-potential DFT calculations within the local density approximation (LDA) were performed. Using the resulting band structure, a consistent set of transfer integrals for an effective one-band tight-binding model was obtained. Electronic correlations were treated on a mean-field level starting from LDA (LSDA+U method) and on a model level (Hubbard model). In excellent agreement of experiment and theory, we find that only two couplings in CuSe2O5 are relevant: the nearest-neighbour intra-chain interaction of 165 K and a non-frustrated inter-chain coupling of 20 K. From a comparison with structurally related systems (Sr2Cu(PO4)2, Bi2CuO4), general implications for a magnetic ordering in presence of inter-chain frustration are made.Comment: 20 pages, 8 figures, 3 table

    Remote atomic clock synchronization via satellites and optical fibers

    Get PDF
    In the global network of institutions engaged with the realization of International Atomic Time (TAI), atomic clocks and time scales are compared by means of the Global Positioning System (GPS) and by employing telecommunication satellites for two-way satellite time and frequency transfer (TWSTFT). The frequencies of the state-of-the-art primary caesium fountain clocks can be compared at the level of 10e-15 (relative, 1 day averaging) and time scales can be synchronized with an uncertainty of one nanosecond. Future improvements of worldwide clock comparisons will require also an improvement of the local signal distribution systems. For example, the future ACES (atomic clock ensemble in space) mission shall demonstrate remote time scale comparisons at the uncertainty level of 100 ps. To ensure that the ACES ground instrument will be synchronized to the local time scale at PTB without a significant uncertainty contribution, we have developed a means for calibrated clock comparisons through optical fibers. An uncertainty below 50 ps over a distance of 2 km has been demonstrated on the campus of PTB. This technology is thus in general a promising candidate for synchronization of enhanced time transfer equipment with the local realizations of UTC . Based on these experiments we estimate the uncertainty level for calibrated time transfer through optical fibers over longer distances. These findings are compared with the current status and developments of satellite based time transfer systems, with a focus on the calibration techniques for operational systems

    Parameter selection for the supply system in a Pilger mill

    Full text link
    The braking chamber in the supply system of a Pilger pipe mill is modernized. The influence of constant and variable parameters of the supply system on braking is studied. © 2013 Allerton Press, Inc
    corecore