17 research outputs found

    Use of data mining and spectral profiles to differentiate condition after harvest of coffee plants Discriminação de diferentes estados de plantios de café pós-colheita, por meio da técnica de mineração de dados e perfis espectrais

    Get PDF
    This study aimed at identifying different conditions of coffee plants after harvesting period, using data mining and spectral behavior profiles from Hyperion/EO1 sensor. The Hyperion image, with spatial resolution of 30 m, was acquired in August 28th, 2008, at the end of the coffee harvest season in the studied area. For pre-processing imaging, atmospheric and signal/noise effect corrections were carried out using Flaash and MNF (Minimum Noise Fraction Transform) algorithms, respectively. Spectral behavior profiles (38) of different coffee varieties were generated from 150 Hyperion bands. The spectral behavior profiles were analyzed by Expectation-Maximization (EM) algorithm considering 2; 3; 4 and 5 clusters. T-test with 5% of significance was used to verify the similarity among the wavelength cluster means. The results demonstrated that it is possible to separate five different clusters, which were comprised by different coffee crop conditions making possible to improve future intervention actions.<br>Este trabalho teve o objetivo de identificar diferentes condições na cultura do café, após a colheita, utilizando mineração de dados e curvas espectrais obtidas do sensor Hyperion/EO1.A imagem Hyperion, com resolução espacial de 30 m,foi obtida em 28 de agosto de 2008, fim de safra do café na área de estudo.Como pré-processamentos, foram realizadas a correção atmosférica através do algoritmo Flaash e a correção do sinal/ruído pelo algoritmo MNF (Minimum Noise Fraction Transform). Posteriormente, foram geradas curvas espectrais (38) de 150 comprimentos de onda, que foram analisadas através do algoritmo EM (Expectation-Maximization), considerando simulações de 2; 3; 4 e 5 clusters. Para verificar a igualdade das médias dos comprimentos de onda dos clusters, foi utilizado o teste t, com 5% de significância. Os resultados mostraram que foi possível separar os cafés em cinco diferentes grupos, segundo sua condição pós-colheita, possibilitando melhorar ações futuras de intervenção

    Flow-injection spectrophotometric determination of captopril in pharmaceutical formulations using a new solid-phase reactor containing AgSCN immobilized in a polyurethane resin

    Get PDF
    A simple flow-injection analysis procedure was developed for determining captopril in pharmaceutical formulations employing a novel solid-phase reactor containing silver thiocyanate immobilized in a castor oil derivative polyurethane resin. The method was based on silver mercaptide formation between the captopril and Ag(I) in the solid-phase reactor. During such a reaction, the SCN- anion was released and reacted with Fe3+, which generated the FeSCN2+ complex that was continuously monitored at 480 nm. The analytical curve was linear in the captopril concentration range from 3.0 × 10-4 mol L-1 to 1.1 × 10-3 mol L-1 with a detection limit of 8.0 × 10-5 mol L-1. Recoveries between 97.5% and 103% and a relative standard deviation of 2% for a solution containing 6.0 × 10-4 mol L-1 captopril (n = 12) were obtained. The sample throughput was 40 h-1 and the results obtained for captopril in pharmaceutical formulations using this procedure and those obtained using a pharmacopoeia procedure were in agreement at a 95% confidence level.<br>Um procedimento simples de análise por injeção em fluxo foi desenvolvido para a determinação de captopril em formulações farmacêuticas empregando um novo reator em fase sólida contendo tiocianato de prata imobilizado em resina poliuretana obtida a partir de óleo de mamona. O método foi baseado na formação de um mercapto composto de prata, no reator em fase sólida, obtido entre o captopril e Ag (I) imobilizada. Durante a reação, íons SCN- eram liberados e reagiam com Fe3+, gerando o complexo FeSCN2+, que foi continuamente monitorado em 480 nm. A curva analítica foi linear no intervalo de concentração de captopril entre 3,0 × 10-4 a 1,1 × 10-3 mol L-1 com um limite de detecção de 8,0 × 10-5 mol L-1. Recuperações entre 97,5-103% e desvio padrão relativo de 2% para uma solução contendo 6,0 × 10-4 mol L-1 de captopril (n = 12) foram obtidos. A frequência de amostragem foi de 40 h-1 e os resultados obtidos para captopril em formulações farmacêuticas utilizando este procedimento e o da Farmacopeia, estão de acordo em um nível de confiança de 95%
    corecore