2,540 research outputs found

    Tomographic laser absorption spectroscopy using Tikhonov regularization

    Full text link
    The application of tunable diode laser absorption spectroscopy (TDLAS) to flames with non-homogeneous temperature and concentration fields is an area where only few studies exist. Experimental work explores the performance of tomographic reconstructions of concentration and temperature profiles from wavelength-modulated TDLAS measurements within the plume of an axisymmetric McKenna burner. Water vapor transitions at 1391.67 nm and 1442.67 nm are probed using calibration free wavelength modulation spectroscopy with second harmonic detection (WMS-2f). A single collimated laser beam is swept parallel to the burner surface, where scans yield pairs of line-of-sight (LOS) data at multiple radial locations. Radial profiles of absorption data are reconstructed using Tikhonov regularized Abel inversion, which suppresses the amplification of experimental noise that is typically observed for reconstructions with high spatial resolution. Based on spectral data, temperatures and concentrations are calculated point-by-point. Here, a least-squares approach addresses difficulties due to modulation depths that cannot be universally optimized due to a non-uniform domain. Experimental results show successful reconstructions of temperature and concentration profiles based on two-transition, non-optimally modulated WMS-2f and Tikhonov regularized Abel inversion, and thus validate the technique as a viable diagnostic tool for flame measurements.Comment: This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/AO.53.008095. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under la

    Measurement of CO2 concentration and temperature in an aero engine exhaust plume using wavelength modulation spectroscopy

    Get PDF
    In this paper, the 2f/1f tunable diode laser wavelength modulation technique is used for the simultaneous measurement of concentration and temperature of CO2 in the exhaust plume of an aero engine. The suitability of the R48 spectral feature of CO2 at 1997.2 nm is discussed for this application and for further investigations into the application of CO2 tomographic imaging on large-scale aero-engines. To ensure accurate recovery of gas parameters at the high exhaust temperatures a full spectral characterisation of the spectral feature is presented using direct spectroscopy. The 2f/1f method is validated in the laboratory for controlled gas mixtures and temperatures to recover concentration and temperature, showing good agreement with the actual temperature and concentration values. Finally, single path measurements are presented for an aero engine exhaust showing good correlation with the measured engine conditions

    Remote measurement of high preeruptive water vapor emissions at Sabancaya volcano by passive differential optical absorption spectroscopy

    Get PDF
    Water (H2O) is by far the most abundant volcanic volatile species and plays a predominant role in driving volcanic eruptions. However, numerous difficulties associated with making accurate measurements of water vapor in volcanic plumes have limited their use as a diagnostic tool. Here we present the first detection of water vapor in a volcanic plume using passive visible-light differential optical absorption spectroscopy (DOAS). Ultraviolet and visible-light DOAS measurements were made on 21 May 2016 at Sabancaya Volcano, Peru. We find that Sabancaya's plume contained an exceptionally high relative water vapor abundance 6 months prior to its November 2016 eruption. Our measurements yielded average sulfur dioxide (SO2) emission rates of 800–900 t/d, H2O emission rates of around 250,000 t/d, and an H2O/SO2 molecular ratio of 1000 which is about an order of magnitude larger than typically found in high-temperature volcanic gases. We attribute the high water vapor emissions to a boiling-off of Sabancaya's hydrothermal system caused by intrusion of magma to shallow depths. This hypothesis is supported by a significant increase in the thermal output of the volcanic edifice detected in infrared satellite imagery leading up to and after our measurements. Though the measurement conditions encountered at Sabancaya were very favorable for our experiment, we show that visible-light DOAS systems could be used to measure water vapor emissions at numerous other high-elevation volcanoes. Such measurements would provide observatories with additional information particularly useful for forecasting eruptions at volcanoes harboring significant hydrothermal systems

    Near infrared tunable diode laser spectroscopy for aero engine related applications

    Get PDF
    Tunable diode laser spectroscopy is a widely used technique for recovering quantitative gas information in a range of industrial applications. Established methods often use readily available, robust and low cost optoelectronic hardware in the near-infrared, with output wavelengths that coincide with the absorption spectra of several important gas species of interest, providing a versatile platform for gas analysis instrumentation. In this work the challenges associated with the recovery of gas information from harsh detection environments, particularly for aero engine diagnostics, are considered. For stand-alone instrumentation, calibration-free direct absorption measurements are highly advantageous yet calibrated techniques employing wavelength modulation spectroscopy are often favoured due to their significantly higher sensitivities. Recent developments have enabled calibration-free line shape recovery using lock-in amplifier detection of the residual amplitude modulation in wavelength modulated signals. These techniques have significant potential in harsh environments, but the overall sensitivity is limited by distortions to the recovered line shapes at high modulation amplitudes and by large background signals that saturate the detection electronics. In this thesis, solutions to these two problems are proposed, investigated and validated. A correction function is derived that is able to account for line shape distortions at arbitrarily high modulation indices. Application of the function depends upon knowledge of the experimental modulation index and two methods for extracting this information directly from the experimental signals are described. The full correction procedure has been experimentally validated. An investigation was made into the use of autobalanced photoreceivers, typically used for common mode noise cancellation, for direct absorption measurements and in a different configuration for nulling of the residual amplitude modulation (RAM) in wavelength modulation spectroscopy. Initial measurements suggest that removal of the background RAM can increase the lock-in detection sensitivity by over an order of magnitude. In addition an external amplitude modulator has been iv shown to be an effective method for producing sensitive absorption signals that are free of distortions, recoverable at frequencies that are outside the bandwidth of most environmental noise sources. A temperature sensor based on ratio thermometry of ambient water vapour absorption was designed and evaluated. The sensor is intended to provide accurate intake gas temperature information during aero engine ground testing when misting conditions prevent standard thermocouples from providing reliable data. Direct detection and second harmonic wavelength modulation spectroscopy experiments were undertaken in an environmental chamber, over the range 273-313K, to test the potential accuracy of the proposed system. Using a second harmonic peak height method, temperature information based on a calibration was able to recover temperature measurements with precision of ±0.4K however the overall accuracy suffered from a problematic calibration drift. Three engine test campaigns are described in which a range of recovery methods and potential optical system layouts are evaluated for the purposes of intake and exhaust mounted test bed sensor systems. The effects of extreme noise conditions were observed on a variety of measurements and favourable detection and modulation options were identified for the purpose of planning proposed future engine tests. Exhaust plume measurements of high temperature water vapour on the Rolls-Royce Environmentally Friendly Engine demonstrator established the viability of temperature and concentration measurements up to 850K.Tunable diode laser spectroscopy is a widely used technique for recovering quantitative gas information in a range of industrial applications. Established methods often use readily available, robust and low cost optoelectronic hardware in the near-infrared, with output wavelengths that coincide with the absorption spectra of several important gas species of interest, providing a versatile platform for gas analysis instrumentation. In this work the challenges associated with the recovery of gas information from harsh detection environments, particularly for aero engine diagnostics, are considered. For stand-alone instrumentation, calibration-free direct absorption measurements are highly advantageous yet calibrated techniques employing wavelength modulation spectroscopy are often favoured due to their significantly higher sensitivities. Recent developments have enabled calibration-free line shape recovery using lock-in amplifier detection of the residual amplitude modulation in wavelength modulated signals. These techniques have significant potential in harsh environments, but the overall sensitivity is limited by distortions to the recovered line shapes at high modulation amplitudes and by large background signals that saturate the detection electronics. In this thesis, solutions to these two problems are proposed, investigated and validated. A correction function is derived that is able to account for line shape distortions at arbitrarily high modulation indices. Application of the function depends upon knowledge of the experimental modulation index and two methods for extracting this information directly from the experimental signals are described. The full correction procedure has been experimentally validated. An investigation was made into the use of autobalanced photoreceivers, typically used for common mode noise cancellation, for direct absorption measurements and in a different configuration for nulling of the residual amplitude modulation (RAM) in wavelength modulation spectroscopy. Initial measurements suggest that removal of the background RAM can increase the lock-in detection sensitivity by over an order of magnitude. In addition an external amplitude modulator has been iv shown to be an effective method for producing sensitive absorption signals that are free of distortions, recoverable at frequencies that are outside the bandwidth of most environmental noise sources. A temperature sensor based on ratio thermometry of ambient water vapour absorption was designed and evaluated. The sensor is intended to provide accurate intake gas temperature information during aero engine ground testing when misting conditions prevent standard thermocouples from providing reliable data. Direct detection and second harmonic wavelength modulation spectroscopy experiments were undertaken in an environmental chamber, over the range 273-313K, to test the potential accuracy of the proposed system. Using a second harmonic peak height method, temperature information based on a calibration was able to recover temperature measurements with precision of ±0.4K however the overall accuracy suffered from a problematic calibration drift. Three engine test campaigns are described in which a range of recovery methods and potential optical system layouts are evaluated for the purposes of intake and exhaust mounted test bed sensor systems. The effects of extreme noise conditions were observed on a variety of measurements and favourable detection and modulation options were identified for the purpose of planning proposed future engine tests. Exhaust plume measurements of high temperature water vapour on the Rolls-Royce Environmentally Friendly Engine demonstrator established the viability of temperature and concentration measurements up to 850K

    High-current anode phenomena in vacuum arcs

    Get PDF
    The goal of the work is to investigate the high-current anode phenomena using spectroscopic methods as well as electrical measurements. Different current waveforms and vacuum interrupter properties on the formation of high-current anode phenomena are investigated. Optical emission spectroscopy combined with high-speed camera imaging is used to investigate the temporal and spatial distribution of different species during discharge modes. The ground state density of Cr I before and after current zero is calculated. A new electric arc model based on the existence diagram is proposed

    Workshop on Advanced Technologies for Planetary Instruments, part 1

    Get PDF
    This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. This volume contains papers presented at the Workshop on Advanced Technologies for Planetary Instruments on 28-30 Apr. 1993. This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. Over the past several years, SDIO has sponsored a significant technology development program aimed, in part, at the production of instruments with these characteristics. This workshop provided an opportunity for specialists from the planetary science and DoD communities to establish contacts, to explore common technical ground in an open forum, and more specifically, to discuss the applicability of SDIO's technology base to planetary science instruments

    Development of Imaging Fourier-Transform Spectroscopy for the Characterization of Turbulent Jet Flames

    Get PDF
    Recent advances in computational models to simulate turbulent, reactive flow fields have outpaced the ability to collect highly constraining data--throughout the entire flow field--for validating and improving such models. In particular, the ability to quantify in three dimensions both the mean scalar fields (i.e. temperature & species concentrations) and their respective fluctuation statistics via hyperspectral imaging would be a game-changing advancement in combustion diagnostics, with high impact in both validation and improvement efforts for computational combustion models. This research effort establishes imaging Fourier-transform spectrometry (IFTS) as a valuable tool (which complements laser diagnostics) for the study of turbulent combustion. Specifically, this effort (1) demonstrates that IFTS can be used to quantitatively measure spatially resolved spectra from a canonical turbulent flame; (2) establishes the utility of quantile spectra in first-ever quantitative comparisons between measured and modeled turbulent radiation interaction (TRI); (3) develops a simple onion-peeling-like spectral inversion methodology suitable for estimating radial scalar distributions in axisymmetric, optically-thick flames; (4) builds understanding of quantile spectra and demonstrates proof of concept for their use in estimating scalar fluctuation statistics
    • …
    corecore