1,207 research outputs found

    NASA SBIR abstracts of 1991 phase 1 projects

    Get PDF
    The objectives of 301 projects placed under contract by the Small Business Innovation Research (SBIR) program of the National Aeronautics and Space Administration (NASA) are described. These projects were selected competitively from among proposals submitted to NASA in response to the 1991 SBIR Program Solicitation. The basic document consists of edited, non-proprietary abstracts of the winning proposals submitted by small businesses. The abstracts are presented under the 15 technical topics within which Phase 1 proposals were solicited. Each project was assigned a sequential identifying number from 001 to 301, in order of its appearance in the body of the report. Appendixes to provide additional information about the SBIR program and permit cross-reference of the 1991 Phase 1 projects by company name, location by state, principal investigator, NASA Field Center responsible for management of each project, and NASA contract number are included

    Mechatronic Systems

    Get PDF
    Mechatronics, the synergistic blend of mechanics, electronics, and computer science, has evolved over the past twenty five years, leading to a novel stage of engineering design. By integrating the best design practices with the most advanced technologies, mechatronics aims at realizing high-quality products, guaranteeing at the same time a substantial reduction of time and costs of manufacturing. Mechatronic systems are manifold and range from machine components, motion generators, and power producing machines to more complex devices, such as robotic systems and transportation vehicles. With its twenty chapters, which collect contributions from many researchers worldwide, this book provides an excellent survey of recent work in the field of mechatronics with applications in various fields, like robotics, medical and assistive technology, human-machine interaction, unmanned vehicles, manufacturing, and education. We would like to thank all the authors who have invested a great deal of time to write such interesting chapters, which we are sure will be valuable to the readers. Chapters 1 to 6 deal with applications of mechatronics for the development of robotic systems. Medical and assistive technologies and human-machine interaction systems are the topic of chapters 7 to 13.Chapters 14 and 15 concern mechatronic systems for autonomous vehicles. Chapters 16-19 deal with mechatronics in manufacturing contexts. Chapter 20 concludes the book, describing a method for the installation of mechatronics education in schools

    Automated visual inspection for the quality control of pad printing

    Get PDF
    Pad printing is used to decorate consumer goods largely because of its unique ability to apply graphics to doubly curved surfaces. The Intelpadrint project was conceived to develop a better understanding of the process and new printing pads, inks and printers. The thesis deals primarily with the research of a printer control system including machine vision. At present printing is manually controlled. Operator knowledge was gathered for use by an expert system to control the process. A novel local corner- matching algorithm was conceived to effect image segmentation, and neuro-fuzzy techniques were used to recognise patterns in printing errors. Non-linear Finite Element Analysis of the rubber printing-pad led to a method for pre-distorting artwork so that it would print undistorted on a curved product. A flexible, more automated printer was developed that achieves a higher printing rate. Ultraviolet-cured inks with improved printability were developed. The image normalisation/ error-signalling stage in inspection was proven in isolation, as was the pattern recognition system

    1992 NASA/ASEE Summer Faculty Fellowship Program

    Get PDF
    For the 28th consecutive year, a NASA/ASEE Summer Faculty Fellowship Program was conducted at the Marshall Space Flight Center (MSFC). The program was conducted by the University of Alabama and MSFC during the period June 1, 1992 through August 7, 1992. Operated under the auspices of the American Society for Engineering Education, the MSFC program, was well as those at other centers, was sponsored by the Office of Educational Affairs, NASA Headquarters, Washington, DC. The basic objectives of the programs, which are the 29th year of operation nationally, are (1) to further the professional knowledge of qualified engineering and science faculty members; (2) to stimulate and exchange ideas between participants and NASA; (3) to enrich and refresh the research and teaching activities of the participants' institutions; and (4) to contribute to the research objectives of the NASA centers

    Novel control of a high performance rotary wood planing machine

    Get PDF
    Rotary planing, and moulding, machining operations have been employed within the woodworking industry for a number of years. Due to the rotational nature of the machining process, cuttermarks, in the form of waves, are created on the machined timber surface. It is the nature of these cuttermarks that determine the surface quality of the machined timber. It has been established that cutting tool inaccuracies and vibrations are a prime factor in the form of the cuttermarks on the timber surface. A principal aim of this thesis is to create a control architecture that is suitable for the adaptive operation of a wood planing machine in order to improve the surface quality of the machined timber. In order to improve the surface quality, a thorough understanding of the principals of wood planing is required. These principals are stated within this thesis and the ability to manipulate the rotary wood planing process, in order to achieve a higher surface quality, is shown. An existing test rig facility is utilised within this thesis, however upgrades to facilitate higher cutting and feed speeds, as well as possible future implementations such as extended cutting regimes, the test rig has been modified and enlarged. This test rig allows for the dynamic positioning of the centre of rotation of the cutterhead during a cutting operation through the use of piezo electric actuators, with a displacement range of Ā±15Ī¼m. A new controller for the system has been generated. Within this controller are a number of tuneable parameters. It was found that these parameters were dependant on a high number external factors, such as operating speeds and runā€out of the cutting knives. A novel approach to the generation of these parameters has been developed and implemented within the overall system. Both cutterhead inaccuracies and vibrations can be overcome, to some degree, by the vertical displacement of the cutterhead. However a crucial information element is not known, the particular displacement profile. Therefore a novel approach, consisting of a subtle change to the displacement profile and then a pattern matching approach, has been implemented onto the test rig. Within the pattern matching approach the surface profiles are simplified to a basic form. This basic form allows for a much simplified approach to the pattern matching whilst producing a result suitable for the subtle change approach. In order to compress the data levels a Principal Component Analysis was performed on the measured surface data. Patterns were found to be present in the resultant data matrix and so investigations into defect classification techniques have been carried out using both Kā€Nearest Neighbour techniques and Neural Networks. The application of these novel approaches has yielded a higher system performance, for no additional cost to the mechanical components of the wood planing machine, both in terms of wood throughput and machined timber surface quality

    Development of a 4-DoF Active Upper Limb Orthosis

    Get PDF
    In this paper, the designs and manufacturing process of a powered upper limb orthosis are presented. The orthosis is an exoskeleton worn on one arm by the user and fixed to the trunk. The orthosisā€™ architecture, design, and manufacturing process are presented and discussed. Estimations of the ranges of movement related to daily living activities are presented. The preliminary tests to verify the functionality of the design show encouraging results

    Benchmarking foreign electronics technologies

    Full text link

    Building And Validating Next-Generation Neurodevices Using Novel Materials, Fabrication, And Analytic Strategies

    Get PDF
    Technologies that enable scientists to record and modulate neural activity across spatial scales are advancing the way that neurological disorders are diagnosed and treated, and fueling breakthroughs in our fundamental understanding of brain function. Despite the rapid pace of technology development, significant challenges remain in realizing safe, stable, and functional interfaces between manmade electronics and soft biological tissues. Additionally, technologies that employ multimodal methods to interrogate brain function across temporal and spatial scales, from single cells to large networks, offer insights beyond what is possible with electrical monitoring alone. However, the tools and methodologies to enable these studies are still in their infancy. Recently, carbon nanomaterials have shown great promise to improve performance and multimodal capabilities of bioelectronic interfaces through their unique optical and electronic properties, flexibility, biocompatibility, and nanoscale topology. Unfortunately, their translation beyond the lab has lagged due to a lack of scalable assembly methods for incorporating such nanomaterials into functional devices. In this thesis, I leverage carbon nanomaterials to address several key limitations in the field of bioelectronic interfaces and establish scalable fabrication methods to enable their translation beyond the lab. First, I demonstrate the value of transparent, flexible electronics by analyzing simultaneous optical and electrical recordings of brain activity at the microscale using custom-fabricated graphene electronics. Second, I leverage a recently discovered 2D nanomaterial, Ti3C2 MXene, to improve the capabilities and performance of neural microelectronic devices. Third, I fabricate and validate human-scale Ti3C2 MXene epidermal electrode arrays in clinical applications. Leveraging the unique solution-processability of Ti3C2 MXene, I establish novel fabrication methods for both high-resolution microelectrode arrays and macroscale epidermal electrode arrays that are scalable and sufficiently cost-effective to allow translation of MXene bioelectronics beyond the lab and into clinical use. Thetechnologies and methodologies developed in this thesis advance bioelectronic technology for both research and clinical applications, with the goal of improving patient quality of life and illuminating complex brain dynamics across spatial scales
    • ā€¦
    corecore