    Power calculation algorithm for single-phase droop-operated inverters considering nonlinear loads and unsing n-order SOGI filtering

    Get PDF
    The average active and reactive powers, P and Q, are crucial parameters that have to be calculated when sharing common loads between parallelized droop-operated single-phase inverters. However, the droop method algorithm should employ low-pass filters (LPF) with very low cut-off frequency to minimize the distortion impact in the provide droop amplitude and frequency references. This situation forces the droop control to operate at a very low dynamic velocity, degrading the stability of the parallelized system. For this reason, different solutions had been proposed in literature to increase the droop velocity, but the issues derived from the sharing of nonlinear loads had not been properly considered. This work proposes a novel method to calculate P and Q based on the fundamental components of the inverter's output voltage and current and using the measured phase angle between the output voltage and current. The method is used under normal and highly distorting conditions due to the sharing non-linear loads. The fundamental components are obtained by means of the highly filtering capability provided by norder cascaded second order generalized integrators (nSOGI). The proposed method leads to faster and more accurate P and Q calculations that enhances the droop-method dynamic performance. Simulations are provided to validate the proposal.Peer ReviewedPostprint (published version

    Voltage Stabilization in Microgrids via Quadratic Droop Control

    Full text link
    We consider the problem of voltage stability and reactive power balancing in islanded small-scale electrical networks outfitted with DC/AC inverters ("microgrids"). A droop-like voltage feedback controller is proposed which is quadratic in the local voltage magnitude, allowing for the application of circuit-theoretic analysis techniques to the closed-loop system. The operating points of the closed-loop microgrid are in exact correspondence with the solutions of a reduced power flow equation, and we provide explicit solutions and small-signal stability analyses under several static and dynamic load models. Controller optimality is characterized as follows: we show a one-to-one correspondence between the high-voltage equilibrium of the microgrid under quadratic droop control, and the solution of an optimization problem which minimizes a trade-off between reactive power dissipation and voltage deviations. Power sharing performance of the controller is characterized as a function of the controller gains, network topology, and parameters. Perhaps surprisingly, proportional sharing of the total load between inverters is achieved in the low-gain limit, independent of the circuit topology or reactances. All results hold for arbitrary grid topologies, with arbitrary numbers of inverters and loads. Numerical results confirm the robustness of the controller to unmodeled dynamics.Comment: 14 pages, 8 figure

    A power calculation algorithm for single-phase droop-operated-inverters considering linear and nonlinear loads HIL-assessed

    Get PDF
    The active and reactive powers, P and Q, are crucial variables in the parallel operation of single-phase inverters using the droop method, introducing proportional droops in the inverter output frequency and voltage amplitude references. P and Q, or P-Q, are calculated as the product of the inverter output voltage and its orthogonal version with the output current, respectively. However, when sharing nonlinear loads these powers, Pav and Qav, should be averaged by low-pass filters (LPFs) with a very low cut-off frequency to avoid the high distortion induced by these loads. This forces the droop method to operate at a very low dynamic velocity and degrades the system stability. Then, different solutions have been proposed in literature to increase the system velocity, but only considering linear loads. Therefore, this work presents a method to calculate Pav and Qav using second-order generalized integrators (SOGI) to face this problem with nonlinear loads. A double SOGI (DSOGI) approach is applied to filter the nonlinear load current and provide its fundamental component to the inverter, leading to a faster dynamic velocity of the droop-based load sharing capability and improving the stability. The proposed method is shown to be faster than others in the literature when considering nonlinear loads, while smoothly driving the system with low distortion levels. Simulations, hardware-in-loop (HIL) and experimental results are provided to validate this proposal

    A power calculation algorithm for single-phase droop-operated-inverters considering linear and nonlinear loads HIL-assessed

    Get PDF
    The active and reactive powers, P and Q, are crucial variables in the parallel operation of single-phase inverters using the droop method, introducing proportional droops in the inverter output frequency and voltage amplitude references. P and Q, or P-Q, are calculated as the product of the inverter output voltage and its orthogonal version with the output current, respectively. However, when sharing nonlinear loads these powers, Pav and Qav, should be averaged by low-pass filters (LPFs) with a very low cut-o frequency to avoid the high distortion induced by these loads. This forces the droop method to operate at a very low dynamic velocity and degrades the system stability. Then, di erent solutions have been proposed in literature to increase the system velocity, but only considering linear loads. Therefore, this work presents a method to calculate Pav and Qav using second-order generalized integrators (SOGI) to face this problem with nonlinear loads. A double SOGI (DSOGI) approach is applied to filter the nonlinear load current and provide its fundamental component to the inverter, leading to a faster dynamic velocity of the droop-based load sharing capability and improving the stability. The proposed method is shown to be faster than others in the literature when considering nonlinear loads, while smoothly driving the system with low distortion levels. Simulations, hardware-in-loop (HIL) and experimental results are provided to validate this proposal.Peer ReviewedPostprint (published version

    Reliability Improvement of Autonomous Microgrids through Interconnection and Storage

    Get PDF
    This thesis deals with reliability and power quality improvement in autonomous microgrids. The reliability is improved through the interconnection of storage, intertying two neighbouring microgrids and interlinking of microgrids cluster through a common power exchange highway. The power quality is improved by interconnecting distributed static compensator (DSTATCOM) in the microgrid. All the proposed methods are verified through extensive digital computer simulation using PSCAD

    Grid fault ride through for wind turbine doubly-fed induction generators

    Get PDF
    EngD ThesisWind farms must contribute to the stability and reliability of the transmission grid, if they are to form a robust component of the electrical network. This includes providing grid support during grid faults, or voltage dips. Transmission system grid codes require wind farms to remain connected during specified voltage dips, and to supply active and reactive power into the network. Doubly-fed induction generator (DFIG) technology is presently dominant in the growing global market for wind power generation, due to the combination of variable-speed operation and a cost-effective partially-rated power converter. However, the DFIG is sensitive to dips in supply voltage. Without specific protection to 'ride through' grid faults a DFIG risks damage to its power converter due to over-current and/or overvoltage. Conventional converter protection via a sustained period of rotor-crowbar closed-circuit leads to poor power output and sustained suppression of the stator voltages. This thesis presents a detailed understanding of wind turbine DFIG grid fault response, including flux linkage behaviour and magnetic drag effects. A flexible 7.5kW test facility is used to validate the description of fault response and evaluate techniques for improving fault ride-through performance. A minimum threshold rotor crowbar method is presented, successfully diverting transient over-currents and restoring good power control within 45ms of both fault initiation and clearance. Crowbar application periods were reduced to 11-16ms. A study of the maximum crowbar resistance suggests that this method can be used with high-power DFIG turbines. Alternatively, a DC-link brake method is shown to protect the power converter and quench the transient rotor currents, allowing control to be resumed; albeit requiring 100ms to restore good control. A VAr-support control scheme reveals a 14% stator voltage increase in fault tests: reducing the step-voltage impact at fault clearance and potentially assisting the fault response of other local equipment.EPSR

    Parallel solution of power system linear equations

    Get PDF
    At the heart of many power system computations lies the solution of a large sparse set of linear equations. These equations arise from the modelling of the network and are the cause of a computational bottleneck in power system analysis applications. Efficient sequential techniques have been developed to solve these equations but the solution is still too slow for applications such as real-time dynamic simulation and on-line security analysis. Parallel computing techniques have been explored in the attempt to find faster solutions but the methods developed to date have not efficiently exploited the full power of parallel processing. This thesis considers the solution of the linear network equations encountered in power system computations. Based on the insight provided by the elimination tree, it is proposed that a novel matrix structure is adopted to allow the exploitation of parallelism which exists within the cutset of a typical parallel solution. Using this matrix structure it is possible to reduce the size of the sequential part of the problem and to increase the speed and efficiency of typical LU-based parallel solution. A method for transforming the admittance matrix into the required form is presented along with network partitioning and load balancing techniques. Sequential solution techniques are considered and existing parallel methods are surveyed to determine their strengths and weaknesses. Combining the benefits of existing solutions with the new matrix structure allows an improved LU-based parallel solution to be derived. A simulation of the improved LU solution is used to show the improvements in performance over a standard LU-based solution that result from the adoption of the new techniques. The results of a multiprocessor implementation of the method are presented and the new method is shown to have a better performance than existing methods for distributed memory multiprocessors
    • …