UHF diagnostic monitoring techniques for power transformers
This paper initially gives an introduction to ultra-high frequency (UHF) partial discharge monitoring techniques and their application to gas insulated substations. Recent advances in the technique, covering its application to power transformers, are then discussed and illustrated by means of four site trials. Mounting and installation of the UHF sensors is described and measurements of electrical discharges inside transformers are presented in a range of formats, demonstrating the potential of the UHF method. A procedure for locating sources of electrical discharge is described and demonstrated by means of a practical example where a source of sparking on a tap changer lead was located to within 15 cm. Progress with the development of a prototype on-line monitoring and diagnostic system is reviewed and possible approaches to its utilization are discussed. New concepts for enhancing the capabilities of the UHF technique are presented, including the possibility of monitoring the internal mechanical integrity of plant. The research presented provides sufficient evidence to justify the installation of robust UHF sensors on transformer tanks to facilitate their monitoring if and when required during the service lifetime
Development of an integrated low-power RF partial discharge detector
This paper presents the results from integrating a low-power partial discharge detector with a wireless sensor node designed for operating as part of an IEEE 802.15.4 sensor network, and applying an on-line classifier capable of classifying partial discharges in real-time. Such a system is of benefit to monitoring engineers as it provides a means to exploit the RF technique using a low-cost device while circumventing the need for any additional cabling associated with new condition monitoring systems. The detector uses a frequency-based technique to differentiate between multiple defects, and has been integrated with a SunSPOT wireless sensor node hosting an agent-based monitoring platform, which includes a data capture agent and rule induction agent trained using experimental data. The results of laboratory system verification are discussed, and the requirements for a fully robust and flexible system are outlined
Learning models of plant behavior for anomaly detection and condition monitoring
Providing engineers and asset managers with a too] which can diagnose faults within transformers can greatly assist decision making on such issues as maintenance, performance and safety. However, the onus has always been on personnel to accurately decide how serious a problem is and how urgently maintenance is required. In dealing with the large volumes of data involved, it is possible that faults may not be noticed until serious damage has occurred. This paper proposes the integration of a newly developed anomaly detection technique with an existing diagnosis system. By learning a Hidden Markov Model of healthy transformer behavior, unexpected operation, such as when a fault develops, can be flagged for attention. Faults can then be diagnosed using the existing system and maintenance scheduled as required, all at a much earlier stage than would previously have been possible
Deep neural networks for understanding and diagnosing partial discharge data
Artificial neural networks have been investigated for many years as a technique for automated diagnosis of defects causing partial discharge (PD). While good levels of accuracy have been reported, disadvantages include the difficulty of explaining results, and the need to hand-craft appropriate features for standard two-layer networks. Recent advances in the design and training of deep neural networks, which contain more than two layers of hidden neurons, have resulted in improved results in speech and image recognition tasks. This paper investigates the use of deep neural networks for PD diagnosis. Defect samples constructed in mineral oil were used to generate data for training and testing. The paper demonstrates the improvements in accuracy and visualization of learning which can be gained from deep learning
Partial discharge feature extraction based on ensemble empirical mode decomposition and sample entropy
Partial Discharge (PD) pattern recognition plays an important part in electrical equipment fault diagnosis and maintenance. Feature extraction could greatly affect recognition results. Traditional PD feature extraction methods suffer from high-dimension calculation and signal attenuation. In this study, a novel feature extraction method based on Ensemble Empirical Mode Decomposition (EEMD) and Sample Entropy (SamEn) is proposed. In order to reduce the influence of noise, a wavelet method is applied to PD de-noising. Noise Rejection Ratio (NRR) and Mean Square Error (MSE) are adopted as the de-noising indexes. With EEMD, the de-noised signal is decomposed into a finite number of Intrinsic Mode Functions (IMFs). The IMFs, which contain the dominant information of PD, are selected using a correlation coefficient method. From that, the SamEn of selected IMFs are extracted as PD features. Finally, a Relevance Vector Machine (RVM) is utilized for pattern recognition using the features extracted. Experimental results demonstrate that the proposed method combines excellent properties of both EEMD and SamEn. The recognition results are encouraging with satisfactory accuracy
Detecting execution failures using learned action models
Planners reason with abstracted models of the behaviours they use to construct plans. When plans are turned into the instructions that drive an executive, the real behaviours interacting with the unpredictable uncertainties of the environment can lead to failure. One of the challenges for intelligent autonomy is to recognise when the actual execution of a behaviour has diverged so far from the expected behaviour that it can be considered to be a failure. In this paper we present an approach by which a trace of the execution of a behaviour is monitored by tracking its most likely explanation through a learned model of how the behaviour is normally executed. In this way, possible failures are identified as deviations from common patterns of the execution of the behaviour. We perform an experiment in which we inject errors into the behaviour of a robot performing a particular task, and explore how well a learned model of the task can detect where these errors occur
Time domain analysis of switching transient fields in high voltage substations
Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho
Радиолокационный метод функциональной диагностики ротора газотурбинного авиадвигателя : автореф. дис. … канд. техн. наук : 05.12.14
- …