1,939 research outputs found

    Secondary Frequency and Voltage Control of Islanded Microgrids via Distributed Averaging

    Get PDF
    In this work we present new distributed controllers for secondary frequency and voltage control in islanded microgrids. Inspired by techniques from cooperative control, the proposed controllers use localized information and nearest-neighbor communication to collectively perform secondary control actions. The frequency controller rapidly regulates the microgrid frequency to its nominal value while maintaining active power sharing among the distributed generators. Tuning of the voltage controller provides a simple and intuitive trade-off between the conflicting goals of voltage regulation and reactive power sharing. Our designs require no knowledge of the microgrid topology, impedances or loads. The distributed architecture allows for flexibility and redundancy, and eliminates the need for a central microgrid controller. We provide a voltage stability analysis and present extensive experimental results validating our designs, verifying robust performance under communication failure and during plug-and-play operation.Comment: Accepted for publication in IEEE Transactions on Industrial Electronic

    A decentralized scalable approach to voltage control of DC islanded microgrids

    Get PDF
    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the corresponding DGU. Notably, off-line control design is conducted in a Plug-and-Play (PnP) fashion meaning that (i) the possibility of adding/removing a DGU without spoiling stability of the overall ImG is checked through an optimization problem; (ii) when a DGU is plugged in or out at most neighbouring DGUs have to update their controllers and (iii) the synthesis of a local controller uses only information on the corresponding DGU and lines connected to it. This guarantee total scalability of control synthesis as the ImG size grows or DGU gets replaced. Yes, under mild approximations of line dynamics, we formally guarantee stability of the overall closed-loop ImG. The performance of the proposed controllers is analyzed simulating different scenarios in PSCAD.Comment: arXiv admin note: text overlap with arXiv:1405.242

    Doktrin pengasingan kuasa : falsafah, praktis dan kerelatifan di Malaysia

    Get PDF
    Penulisan ini membincangkan tentang doktrin pengasingan kuasa berdasarkan kerangka teori institusionalisme. Doktrin ini dipraktiskan dalam trias politica atau politik tiga serangkai iaitu badan legislatif, eksekutif dan kehakiman. Falsafah dan praktis doktrin pengasingan kuasa ini adalah ditekankan bagi sesebuah negara bercorak demokrasi untuk mempamerkan wujudnya pengasingan kuasa serta autonomi bidangan di antara ketigatiga badan kerajaan. Hal ini penting untuk disoroti kerana Malaysia tidak terkecuali daripada mengamalkan sistem demokrasi dan pada masa yang sama mempraktiskan doktrin pengasingan kuasa dalam kerajaan federalisme berlapisnya sebagai satu pegangan fundamental. Akauntabiliti untuk menzahirkan doktrin pengasingan kuasa ini merupakan perkara yang penting memandangkan ia telah dimaktubkan dalam Perlembagaan Persekutuan

    Performance evaluation of secondary control policies with respect to digital communications properties in inverter-based islanded microgrids

    Get PDF
    A key challenge for inverted-based microgrids working in islanded mode is to maintain their own frequency and voltage to a certain reference values while regulating the active and reactive power among distributed generators and loads. The implementation of frequency and voltage restoration control policies often requires the use of a digital communication network for real-time data exchange (tertiary control covers the coordi- nated operation of the microgrid and the host grid). Whenever a digital network is placed within the loop, the operation of the secondary control may be affected by the inherent properties of the communication technology. This paper analyses the effect that properties like transmission intervals and message dropouts have for four existing representative approaches to secondary control in a scalable islanded microgrid. The simulated results reveals pros and cons for each approach, and identifies threats that properly avoided or handled in advance can prevent failures that otherwise would occur. Selected experimental results on a low- scale laboratory microgrid corroborate the conclusions extracted from the simulation study.Peer ReviewedPostprint (author's final draft

    Small signal modeling and analysis of microgrid systems

    Get PDF
    This dissertation focuses on small-signal modeling and analysis of inverter based microgrid systems. The proposed microgrid consists of two microsources placed on two different buses. The buses are connected using a distribution feeder with some impedance. The proposed microgrid can operate with the grid support, or without the grid support. When operated without the grid support, the standalone system’s microsources participate in controlling the system voltage and frequency. For a non-inertia source, such as the inverter, the load perturbations play an important role in system dynamics. In paper-I, such complex system was studied. In the grid-tied mode, the microsources share the load demand with other sources that are present in the main grid. The control algorithm for such system is much simpler than that of the islanded system. However, when aggregated in multi-bus system, prohibitively higher order state-space models are formed. In paper-II, a reduced order modeling of such systems was considered. Singular perturbation method was applied to identify the two time-scale property of the system. In paper-III, a similar approach was taken to develop a reduced order model of the islanded system that was developed in paper-I. Application of such reduced order models were illustrated by using them to simulate a modified IEEE-37 bus microgrid system. The islanded microgrids system’s stability is characterized in paper-IV by the Markov Jump Linear System Analysis. Conservative bounds on the expected value of the state were determined from a combination of the Markov process parameters, the dynamics of each linear system, and the magnitude of the impulses. The conclusions were verified with the simulation results. --Abstract, page iii
    • …
    corecore