    Left Ventricular Border Tracking Using Cardiac Motion Models and Optical Flow

    Get PDF
    The use of automated methods is becoming increasingly important for assessing cardiac function quantitatively and objectively. In this study, we propose a method for tracking three-dimensional (3-D) left ventricular contours. The method consists of a local optical flow tracker and a global tracker, which uses a statistical model of cardiac motion in an optical-flow formulation. We propose a combination of local and global trackers using gradient-based weights. The algorithm was tested on 35 echocardiographic sequences, with good results (surface error: 1.35 ± 0.46 mm, absolute volume error: 5.4 ± 4.8 mL). This demonstrates the method’s potential in automated tracking in clinical quality echocardiograms, facilitating the quantitative and objective assessment of cardiac functio

    Tracking the Endocardial Border in Artifact-Prone 3D Images

    Get PDF
    Echocardiography is a commonly-used, safe, and noninvasive method for assessing cardiac dysfunction and related coronary artery disease. The analysis of echocardiograms, whether visual or automated, has traditionally been hampered by the presence of ultrasound artifacts, which obscure the moving myocardial wall. In this study, a novel method is proposed for tracking the endocardial surface in 3D ultrasound images. Artifacts which obscure the myocardium are detected in order to improve the quality of cardiac boundary segmentation. The expectation-maximization algorithm is applied in a stationary and dynamic, cardiac-motion frame-of-reference, and weights are derived accordingly. The weights are integrated with an optical-flow based contour tracking method, which incorporates prior knowledge via a statistical model of cardiac motion. Evaluation on 35 three-dimensional echocardiographic sequences shows that this weighed tracking method significantly improves the tracking results. In conclusion, the proposed weights are able to reduce the influence of artifacts, resulting in a more accurate quantitative analysis

    Automated Analysis of 3D Stress Echocardiography

    Get PDF
    __Abstract__ The human circulatory system consists of the heart, blood, arteries, veins and capillaries. The heart is the muscular organ which pumps the blood through the human body (Fig. 1.1,1.2). Deoxygenated blood flows through the right atrium into the right ventricle, which pumps the blood into the pulmonary arteries. The blood is carried to the lungs, where it passes through a capillary network that enables the release of carbon dioxide and the uptake of oxygen. Oxygenated blood then returns to the heart via the pulmonary veins and flows from the left atrium into the left ventricle. The left ventricle then pumps the blood through the aorta, the major artery which supplies blood to the rest of the body [Drake et a!., 2005; Guyton and Halt 1996]. Therefore, it is vital that the cardiovascular system remains healthy. Disease of the cardiovascular system, if untreated, ultimately leads to the failure of other organs and death

    Augmenting CT cardiac roadmaps with segmented streaming ultrasound

    Get PDF
    Static X-ray computed tomography (CT) volumes are often used as anatomic roadmaps during catheter-based cardiac interventions performed under X-ray fluoroscopy guidance. These CT volumes provide a high-resolution depiction of soft-tissue structures, but at only a single point within the cardiac and respiratory cycles. Augmenting these static CT roadmaps with segmented myocardial borders extracted from live ultrasound (US) provides intra-operative access to real-time dynamic information about the cardiac anatomy. In this work, using a customized segmentation method based on a 3D active mesh, endocardial borders of the left ventricle were extracted from US image streams (4D data sets) at a frame rate of approximately 5 frames per second. The coordinate systems for CT and US modalities were registered using rigid body registration based on manually selected landmarks, and the segmented endocardial surfaces were overlaid onto the CT volume. The root-mean squared fiducial registration error was 3.80 mm. The accuracy of the segmentation was quantitatively evaluated in phantom and human volunteer studies via comparison with manual tracings on 9 randomly selected frames using a finite-element model (the US image resolutions of the phantom and volunteer data were 1.3 x 1.1 x 1.3 mm and 0.70 x 0.82 x 0.77 mm, respectively). This comparison yielded 3.70±2.5 mm (approximately 3 pixels) root-mean squared error (RMSE) in a phantom study and 2.58±1.58 mm (approximately 3 pixels) RMSE in a clinical study. The combination of static anatomical roadmap volumes and dynamic intra-operative anatomic information will enable better guidance and feedback for image-guided minimally invasive cardiac interventions

    Basic Science to Clinical Research: Segmentation of Ultrasound and Modelling in Clinical Informatics

    Get PDF
    The world of basic science is a world of minutia; it boils down to improving even a fraction of a percent over the baseline standard. It is a domain of peer reviewed fractions of seconds and the world of squeezing every last ounce of efficiency from a processor, a storage medium, or an algorithm. The field of health data is based on extracting knowledge from segments of data that may improve some clinical process or practice guideline to improve the time and quality of care. Clinical informatics and knowledge translation provide this information in order to reveal insights to the world of improving patient treatments, regimens, and overall outcomes. In my world of minutia, or basic science, the movement of blood served an integral role. The novel detection of sound reverberations map out the landscape for my research. I have applied my algorithms to the various anatomical structures of the heart and artery system. This serves as a basis for segmentation, active contouring, and shape priors. The algorithms presented, leverage novel applications in segmentation by using anatomical features of the heart for shape priors and the integration of optical flow models to improve tracking. The presented techniques show improvements over traditional methods in the estimation of left ventricular size and function, along with plaque estimation in the carotid artery. In my clinical world of data understanding, I have endeavoured to decipher trends in Alzheimer’s disease, Sepsis of hospital patients, and the burden of Melanoma using mathematical modelling methods. The use of decision trees, Markov models, and various clustering techniques provide insights into data sets that are otherwise hidden. Finally, I demonstrate how efficient data capture from providers can achieve rapid results and actionable information on patient medical records. This culminated in generating studies on the burden of illness and their associated costs. A selection of published works from my research in the world of basic sciences to clinical informatics has been included in this thesis to detail my transition. This is my journey from one contented realm to a turbulent one

    Doctor of Philosophy

    Get PDF
    dissertationCongenital heart defects are classes of birth defects that affect the structure and function of the heart. These defects are attributed to the abnormal or incomplete development of a fetal heart during the first few weeks following conception. The overall detection rate of congenital heart defects during routine prenatal examination is low. This is attributed to the insufficient number of trained personnel in many local health centers where many cases of congenital heart defects go undetected. This dissertation presents a system to identify congenital heart defects to improve pregnancy outcomes and increase their detection rates. The system was developed and its performance assessed in identifying the presence of ventricular defects (congenital heart defects that affect the size of the ventricles) using four-dimensional fetal chocardiographic images. The designed system consists of three components: 1) a fetal heart location estimation component, 2) a fetal heart chamber segmentation component, and 3) a detection component that detects congenital heart defects from the segmented chambers. The location estimation component is used to isolate a fetal heart in any four-dimensional fetal echocardiographic image. It uses a hybrid region of interest extraction method that is robust to speckle noise degradation inherent in all ultrasound images. The location estimation method's performance was analyzed on 130 four-dimensional fetal echocardiographic images by comparison with manually identified fetal heart region of interest. The location estimation method showed good agreement with the manually identified standard using four quantitative indexes: Jaccard index, Sørenson-Dice index, Sensitivity index and Specificity index. The average values of these indexes were measured at 80.70%, 89.19%, 91.04%, and 99.17%, respectively. The fetal heart chamber segmentation component uses velocity vector field estimates computed on frames contained in a four-dimensional image to identify the fetal heart chambers. The velocity vector fields are computed using a histogram-based optical flow technique which is formulated on local image characteristics to reduces the effect of speckle noise and nonuniform echogenicity on the velocity vector field estimates. Features based on the velocity vector field estimates, voxel brightness/intensity values, and voxel Cartesian coordinate positions were extracted and used with kernel k-means algorithm to identify the individual chambers. The segmentation method's performance was evaluated on 130 images from 31 patients by comparing the segmentation results with manually identified fetal heart chambers. Evaluation was based on the Sørenson-Dice index, the absolute volume difference and the Hausdorff distance, with each resulting in per patient average values of 69.92%, 22.08%, and 2.82 mm, respectively. The detection component uses the volumes of the identified fetal heart chambers to flag the possible occurrence of hypoplastic left heart syndrome, a type of congenital heart defect. An empirical volume threshold defined on the relative ratio of adjacent fetal heart chamber volumes obtained manually is used in the detection process. The performance of the detection procedure was assessed by comparison with a set of images with confirmed diagnosis of hypoplastic left heart syndrome and a control group of normal fetal hearts. Of the 130 images considered 18 of 20 (90%) fetal hearts were correctly detected as having hypoplastic left heart syndrome and 84 of 110 (76.36%) fetal hearts were correctly detected as normal in the control group. The results show that the detection system performs better than the overall detection rate for congenital heart defect which is reported to be between 30% and 60%

    Spatio-Temporal Nonrigid Registration for Ultrasound Cardiac Motion Estimation

    Get PDF
    We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensates for the motion by minimizing a difference with respect to a reference frame. The key feature of our method is the use of a semi-local spatio-temporal parametric model for the deformation using splines, and the reformulation of the registration task as a global optimization problem. The scale of the spline model controls the smoothness of the displacement field. Our algorithm uses a multiresolution optimization strategy to obtain a higher speed and robustness. We evaluated the accuracy of our algorithm using a synthetic sequence generated with an ultrasound simulation package, together with a realistic cardiac motion model. We compared our new global multiframe approach with a previous method based on pairwise registration of consecutive frames to demonstrate the benefits of introducing temporal consistency. Finally, we applied the algorithm to the regional analysis of the left ventricle. Displacement and strain parameters were evaluated showing significant differences between the normal and pathological segments, thereby illustrating the clinical applicability of our method
    • …