11,386 research outputs found

    Hubungan di antara pengaturan kerja fleksibel dan prestasi pekerja dalam kalangan ejen insurans wanita

    Get PDF
    Ejen insurans merupakan jurujual pertengahan bagi syarikat insurans di mana mereka memainkan peranan penting dalam memberi khidmat nasihat kewangan (Hannah, 2011). Ejen insurans bekerja berdasarkan persekitaran pengaturan kerja yang fleksibel di mana mereka boleh menyediakan jadual waktu bekerja sendiri. Sebahagian daripada mereka bertemu dengan pelanggan pada waktu perniagaan siang hari, sementara yang lain pula membuat kertas kerja dan menyediakan konsultasi untuk pelanggan pada waktu petang. Kebanyakan mereka bekerja selama 40 jam seminggu dan ada juga beberapa ejen yang bekerja lebih lama daripada 40 jam (Hannah, 2011). Prestasi ejen insurans sangat penting untuk mengekalkan jenama produk insurans. Penilaian terhadap prestasi di kalangan ejen insurans biasanya bergantung kepada kejayaan atau kegagalan mencapai sasaran penjualan (Insurance Agent Job Overview, 2019). Proses menjual produk insurans memerlukan masa kerana mereka perlu mendekati pelanggan sebanyak mungkin dan ketersediaan waktu bekerja yang tidak tetap

    Design, Development, and Evaluation of a Teleoperated Master-Slave Surgical System for Breast Biopsy under Continuous MRI Guidance

    Get PDF
    The goal of this project is to design and develop a teleoperated master-slave surgical system that can potentially assist the physician in performing breast biopsy with a magnetic resonance imaging (MRI) compatible robotic system. MRI provides superior soft-tissue contrast compared to other imaging modalities such as computed tomography or ultrasound and is used for both diagnostic and therapeutic procedures. The strong magnetic field and the limited space inside the MRI bore, however, restrict direct means of breast biopsy while performing real-time imaging. Therefore, current breast biopsy procedures employ a blind targeting approach based on magnetic resonance (MR) images obtained a priori. Due to possible patient involuntary motion or inaccurate insertion through the registration grid, such approach could lead to tool tip positioning errors thereby affecting diagnostic accuracy and leading to a long and painful process, if repeated procedures are required. Hence, it is desired to develop the aforementioned teleoperation system to take advantages of real-time MR imaging and avoid multiple biopsy needle insertions, improving the procedure accuracy as well as reducing the sampling errors. The design, implementation, and evaluation of the teleoperation system is presented in this dissertation. A MRI-compatible slave robot is implemented, which consists of a 1 degree of freedom (DOF) needle driver, a 3-DOF parallel mechanism, and a 2-DOF X-Y stage. This slave robot is actuated with pneumatic cylinders through long transmission lines except the 1-DOF needle driver is actuated with a piezo motor. Pneumatic actuation through long transmission lines is then investigated using proportional pressure valves and controllers based on sliding mode control are presented. A dedicated master robot is also developed, and the kinematic map between the master and the slave robot is established. The two robots are integrated into a teleoperation system and a graphical user interface is developed to provide visual feedback to the physician. MRI experiment shows that the slave robot is MRI-compatible, and the ex vivo test shows over 85%success rate in targeting with the MRI-compatible robotic system. The success in performing in vivo animal experiments further confirm the potential of further developing the proposed robotic system for clinical applications

    Nanoparticle shape effects on squeezed MHD flow of water based Cu, Al2O3 and SWCNTs over a porous sensor surface

    Get PDF
    Impact of nanoparticle shape on the squeezed MHD flow of water based metallic nanoparticles over a porous sensor surface in the presence of heat source has been investigated. In distinctly most paramount studies, three distinctive forms of nanoparticle shapes are employed into account, i.e. sphere ðm ¼ 3:0Þ, cylinder ðm ¼ 6:3698Þ and laminar ðm ¼ 16:1576Þ. The controlling partial differential equations (PDEs) are regenerated into ordinary differential equations (ODEs) by manipulating consistent conformity conversion and it is determined numerically by handling Runge Kutta Fehlberg method with shooting technique. It is noticed that the solid volume fraction and nanoparticle shape have powerful outputs in squeezing flow phenomena, the sphere shape nanoparticle in Cu – water and cylindrical shape in SWCNTs-water in the presence of magnetic field along with thermal radiation energy has better improvement on heat transfer as compared with the other nanoparticle shapes in different flow regimes

    Mechatronics at the University of Twente

    Get PDF
    This paper describes some of the mechatronics activities at the University of Twente. In 1989, the founding of the Mechatronics Research Center Twente started a cooperation of the departments of Electrical Engineering, Mechanical Engineering, Applied Mathematics and Computer Science. The mechatronics activities get especially attention in projects in the Ph.D. programme and in the `mechatronic designer' program, but Msc. students participate as well. As an illustration of the philosophy behind the work at the University of Twente and of the activities carried out so far, the paper describes two projects of the institute: the MART (Mobile Autonomous Robot Twente) project and the ALASCA (Automated Laser Aided Servo Controlled Assembly) projec

    Segmented capacitance tomography electrodes: a design and experimental verifications

    Get PDF
    A segmented capacitance tomography system for real-time imaging of multiphase flows is developed and pre-sented in this work. The earlier research shows that the electrical tomography (ECT) system is applicable in flow visualization (image reconstruction). The acquired concentration profile ob-tained from capacitance measurements able to imaged liquid and gas mixture in pipelines meanwhile the system development is designed to attach on a vessel. The electrode plates which act as the sensor previously has been assembled and fixed on the pipeline, thus it causes obscurity for the production to have any new process installation in the future. Therefore, a segmented electrode sensor offers a new design and idea on ECT system which is portable to be assembled in different diameter sizes of pipeline, and it is flexible to apply in any number due to different size of pipeline without the need of redesigning the sensing module. The new ap-proach of this sensing module contains the integration intelligent electrode sensing circuit on every each of electrode sensors. A microcontroller unit and data acquisition (DAQ) system has been integrated on the electrode sensing circuit and USB technology was applied into the data acquisition system making the sensor able to work independently. Other than that the driven guard that usually placed between adjacent measuring electrodes and earth screen has been embedded on the segmented electrode sensor plates. This eliminates the cable noise and the electrode, so the signal conditioning board can be expanded according to pipe diameter

    Grasping and Control Issues in Adaptive End Effectors

    Get PDF
    Research into robotic grasping and manipulation has led to the development of a large number of tendon based end effectors. Many are, however, developed as a research tool, which are limited in application to the laboratory environment. The main reason being that the designs requiring a large number of actuators to be controlled. Due to the space and safety requirements, very few have been developed and commissioned for industrial applications. This paper presents design of a rigid link finger operated by a minimum number of actuators, which may be suitable for a number of adaptive end effectors. The adaptive nature built into the end effector (due to limited number of actuators) presents considerable problems in grasping and control. The paper discusses the issues associated with such designs. The research can be applicable to any adaptive end effectors that are controlled by limited number of actuators and evaluates their suitability in industrial environments
    corecore