275 research outputs found

    Design and Prototyping of a Bio-inspired Kinematic Sensing Suit for the Shoulder Joint: Precursor to a Multi-DoF Shoulder Exosuit

    Get PDF
    Soft wearable robots are a promising new design paradigm for rehabilitation and active assistance applications. Their compliant nature makes them ideal for complex joints like the shoulder, but intuitive control of these robots require robust and compliant sensing mechanisms. In this work, we introduce the sensing framework for a multi-DoF shoulder exosuit capable of sensing the kinematics of the shoulder joint. The proposed tendon-based sensing system is inspired by the concept of muscle synergies, the body's sense of proprioception, and finds its basis in the organization of the muscles responsible for shoulder movements. A motion-capture-based evaluation of the developed sensing system showed conformance to the behaviour exhibited by the muscles that inspired its routing and validates the hypothesis of the tendon-routing to be extended to the actuation framework of the exosuit in the future. The mapping from multi-sensor space to joint space is a multivariate multiple regression problem and was derived using an Artificial Neural Network (ANN). The sensing framework was tested with a motion-tracking system and achieved performance with root mean square error (RMSE) of approximately 5.43 degrees and 3.65 degrees for the azimuth and elevation joint angles, respectively, measured over 29000 frames (4+ minutes) of motion-capture data.Comment: 8 pages, 7 figures, 1 tabl

    ReHand - a portable assistive rehabilitation hand exoskeleton

    Get PDF
    This dissertation presents a synthesis of a novel underactuated exoskeleton (namely ReHand2) thought and designed for a task-oriented rehabilitation and/or for empower the human hand. The first part of this dissertation shows the current context about the robotic rehabilitation with a focus on hand pathologies, which influence the hand capability. The chapter is concluded with the presentation of ReHand2. The second chapter describes the human hand biomechanics. Starting from the definition of human hand anatomy, passing through anthropometric data, to taxonomy on hand grasps and finger constraints, both from static and dynamic point of view. In addition, some information about the hand capability are given. The third chapter analyze the current state of the art in hand exoskeleton for rehabilitation and empower tasks. In particular, the chapter presents exoskeleton technologies, from mechanisms to sensors, passing though transmission and actuators. Finally, the current state of the art in terms of prototype and commercial products is presented. The fourth chapter introduces the concepts of underactuation with the basic explanation and the classical notation used typically in the prosthetic field. In addition, the chapter describe also the most used differential elements in the prosthetic, follow by a statical analysis. Moreover typical transmission tree at inter-finger level as well as the intra- finger underactuation are explained . The fifth chapter presents the prototype called ReHand summarizing the device description and explanation of the working principle. It describes also the kinetostatic analysis for both, inter- and the intra-finger modules. in the last section preliminary results obtained with the exoskeleton are shown and discussed, attention is pointed out on prototype’s problems that have carry out at the second version of the device. The sixth chapter describes the evolution of ReHand, describing the kinematics and dynamics behaviors. In particular, for the mathematical description is introduced the notation used in order to analyze and optimize the geometry of the entire device. The introduced model is also implemented in Matlab Simulink environment. Finally, the chapter presents the new features. The seventh chapter describes the test bench and the methodologies used to evaluate the device statical, and dynamical performances. The chapter presents and discuss the experimental results and compare them with simulated one. Finally in the last chapter the conclusion about the ReHand project are proposed as well as the future development. In particular, the idea to test de device in relevant environments. In addition some preliminary considerations about the thumb and the wrist are introduced, exploiting the possibility to modify the entire layout of the device, for instance changing the actuator location

    Effects of overground walking with a robotic exoskeleton on lower limb muscle synergies

    Full text link
    Les exosquelettes robotisés de marche (ERM) représentent une intervention prometteuse dans le domaine de la réadaptation locomotrice. Sur le plan clinique, les ERM facilitent la mise en application de principes de neuroplasticité. Jusqu'à présent, la majorité des études analysant les effets de l’ERM a été menée avec des ERM fournissant une assistance robotique complète le long d’une trajectoire de mouvements prédéfinie des membres inférieurs (MI) de façon à reproduire la marche de façon quasi parfaite à très basse vitesse. La nouvelle génération d’ERM, maintenant disponible sur le marché, propose de nouveaux modes de contrôles qui permettent, entre autres, une liberté de mouvement accrue aux MIs (c.-à-d. trajectoire non imposée) et une possibilité d’offrir une assistance ou résistance aux mouvements de différentes intensités surtout pendant la phase d’oscillation du cycle de marche. Cependant, les effets de ces modes de contrôles sur la coordination musculaire des MI pendant la marche au sol avec l’ERM, caractérisé via l’extraction de synergies musculaires (SM), restent méconnus. Cette thèse mesure et compare les caractéristiques des SM (c.-à-d. nombre, profils d’activation, composition musculaire et contribution relative des muscles) pendant la la marche au sol sans ou avec un ERM paramétré avec six différents modes de contrôle chez des individus en bonne santé (articles #1 et #2) et d’autres ayant une lésion médullaire incomplète (LMI) (article #3). Les signaux électromyographiques (EMG) des différents muscles clés des MI, enregistrés lors de la marche, ont été utilisés afin d’extraire les SM avec un algorithme de factorisation matricielle non négative. La similarité des cosinus et les coefficients de corrélation ont caractérisé les similitudes entre les caractéristiques des SM. Les résultats montrent que: 1) les profils d'activation temporelle et le nombre de SM sont modifiés en fonction de la vitesse de marche avec, entre autres une augmentation de la vitesse de marche entrainant une fusion de SM, chez les individus en bonne santé marchant sans ERM ; 2) lorsque ces derniers marchent avec un ERM, les différents modes de contrôle testés ne dupliquent pas adéquatement les SM retrouvées lors de la marche sans ERM. En fait, uniquement le mode de contrôle libérant la contrainte de trajectoire de mouvements des MIs dans le plan sagittal lors de la phase d’oscillation reproduit les principales caractéristiques des SM retrouvées pendant la marche sans ERM ; 3) le nombre et la composition musculaire des SM sont modifiés pendant la marche sans ERM chez les personnes ayant une LMI. Cependant, parmi tous les modes de contrôle étudiés, seul le mode de contrôle libérant le contrôle de la trajectoire de mouvements des MI et assistant l’oscillation du MIs (c.-à-d. HASSIST) permets l’extraction de SM similaire à celles observées chez des individus en santé lors d'une marche sans ERM. Dans l’ensemble, cette thèse a mis en évidence le fait que différentes demandes biomécaniques liées à la marche (c.-à-d. vitesse de marche, modes de contrôle de l’ERM) modifient le nombre et les caractéristiques de SM chez les personnes en santé. Cette thèse a également confirmé que la coordination musculaire, mise en évidence via l’analyse de SM, est altérée chez les personnes ayant une LMI et a tendance à se normaliser lors de la marche avec l’ERM paramétré dans le mode de HASSIST. Les nouvelles preuves appuieront les professionnels de la réadaptation dans le processus de prise de décision concernant la sélection du mode de contrôle des MIs lors de l’entrainement locomoteur utilisant avec un ERM.Wearable robotic exoskeletons (WRE) represent a promising rehabilitation intervention for locomotor rehabilitation training that aligns with activity-based neuroplasticity principles in terms of optimal sensory input, massed repetition, and proper kinematics. Thus far, most studies that investigated the effects of WRE have used WRE that provide full robotic assistance and fixed trajectory guidance to the lower extremity (L/E) to generate close-to-normal walking kinematics, usually at very slow speeds. Based on clinicians’ feedback, current commercially-available WRE have additional control options to be able to integrate these devices into the recovery process of individuals who have maintained some ability to walk after an injury to the central nervous system. In this context, WRE now offer additional degrees of movements for the L/E to move freely and different strategies to assist or resist movement, particularly during the gait cycle’s swing phase. However, the extent that these additional WRE control options affect L/E neuromuscular control during walking, typically characterized using muscle synergies (MSs), remains unknown. This thesis measures and compares MSs characteristics (i.e., number, temporal activation profile, and muscles contributing to a specific synergy [weightings]) during typical overground walking, with and without a WRE, in six different control modes, in abled-bodied individuals (Articles #1 and #2) and individuals with incomplete spinal cord injury (iSCI; Article #3). Surface EMG of key L/E muscles were recorded while walking and used to extract MSs using a non-negative matrix factorization algorithm. Cosine similarity and correlation coefficients characterized, grouped, and indicated similarities between MS characteristics. Results demonstrated that: 1) the number of MSs and MS temporal activation profiles in able-bodied individuals walking without WRE are modified by walking speed and that, as speed increased, specific MSs were fused or merged compared to MSs at slow speeds; 2) In able-bodied individuals walking with WRE, few WRE control modes maintained the typical MSs characteristics that were found during overground walking without WRE. Moreover, freeing the L/E swing trajectory imposed by the WRE best reproduced those MSs characteristics during overground walking without the WRE; and 3) After an iSCI, alterations to the number and the composition of MSs were observed during walking without WRE. However, of all WRE control modes that were investigated, only HASSIST (i.e., freeing WRE control over L/E swing trajectory while assisting the user’s self-selected trajectory) reproduced the number and composition of MSs found in abled-bodied individuals during overground walking without WRE. Altogether, the results of this thesis demonstrated that different walking-related biomechanical demands (i.e., walking speed) and most of the WRE control modes can alter some MSs, and their characteristics, in able-bodied individuals. This research also confirmed that impaired muscle coordination, assessed via MSs, can adapt when walking with a WRE set with specific control options (e.g., HASSIST). These MS adaptations mimicked typical MS characteristics extracted during overground walking. The evidence generated by this thesis will support the decision-making process when selecting specific L/E control options during WRE walking, allowing rehabilitation professionals to refine WRE locomotor training protocols

    The role of morphology of the thumb in anthropomorphic grasping : a review

    Get PDF
    The unique musculoskeletal structure of the human hand brings in wider dexterous capabilities to grasp and manipulate a repertoire of objects than the non-human primates. It has been widely accepted that the orientation and the position of the thumb plays an important role in this characteristic behavior. There have been numerous attempts to develop anthropomorphic robotic hands with varying levels of success. Nevertheless, manipulation ability in those hands is to be ameliorated even though they can grasp objects successfully. An appropriate model of the thumb is important to manipulate the objects against the fingers and to maintain the stability. Modeling these complex interactions about the mechanical axes of the joints and how to incorporate these joints in robotic thumbs is a challenging task. This article presents a review of the biomechanics of the human thumb and the robotic thumb designs to identify opportunities for future anthropomorphic robotic hands

    Design and bio-mechanical evaluation of upper-body exoskeletons for physical assistance

    Get PDF

    Real-Time Control of a Multi-Degree-of-Freedom Mirror Myoelectric Interface During Functional Task Training

    Get PDF
    Motor learning mediated by motor training has in the past been explored for rehabilitation. Myoelectric interfaces together with exoskeletons allow patients to receive real-time feedback about their muscle activity. However, the number of degrees of freedom that can be simultaneously controlled is limited, which hinders the training of functional tasks and the effectiveness of the rehabilitation therapy. The objective of this study was to develop a myoelectric interface that would allow multi-degree-of-freedom control of an exoskeleton involving arm, wrist and hand joints, with an eye toward rehabilitation. We tested the effectiveness of a myoelectric decoder trained with data from one upper limb and mirrored to control a multi-degree-of-freedom exoskeleton with the opposite upper limb (i.e., mirror myoelectric interface) in 10 healthy participants. We demonstrated successful simultaneous control of multiple upper-limb joints by all participants. We showed evidence that subjects learned the mirror myoelectric model within the span of a five-session experiment, as reflected by a significant decrease in the time to execute trials and in the number of failed trials. These results are the necessary precursor to evaluating if a decoder trained with EMG from the healthy limb could foster learning of natural EMG patterns and lead to motor rehabilitation in stroke patients.This study was funded by the Eurostars Project E! 113928 Subliminal Home Rehab (SHR), BMBF (Bundesministerium fĂĽr Bildung und Forschung) (FKZ: SHR 01QE2023; and REHOME 16SV8606), FortĂĽne-Program of the University of TĂĽbingen (2452-0-0/1), Ministry of Science of the Basque Country (Elkartek: MODULA KK-2019/00018) and H2020- FETPROACT-EIC-2018-2020 (MAIA 951910)

    Soft Gloves: A Review on Recent Developments in Actuation, Sensing, Control and Applications

    Get PDF
    Interest in soft gloves, both robotic and haptic, has enormously grown over the past decade, due to their inherent compliance, which makes them particularly suitable for direct interaction with the human hand. Robotic soft gloves have been developed for hand rehabilitation, for ADLs assistance, or sometimes for both. Haptic soft gloves may be applied in virtual reality (VR) applications or to give sensory feedback in combination with prostheses or to control robots. This paper presents an updated review of the state of the art of soft gloves, with a particular focus on actuation, sensing, and control, combined with a detailed analysis of the devices according to their application field. The review is organized on two levels: a prospective review allows the highlighting of the main trends in soft gloves development and applications, and an analytical review performs an in-depth analysis of the technical solutions developed and implemented in the revised scientific research. Additional minor evaluations integrate the analysis, such as a synthetic investigation of the main results in the clinical studies and trials referred in literature which involve soft gloves

    Myoelectric Control Systems for Hand Rehabilitation Device: A Review

    Get PDF
    One of the challenges of the hand rehabilitation device is to create a smooth interaction between the device and user. The smooth interaction can be achieved by considering myoelectric signal generated by human's muscle. Therefore, the so-called myoelectric control system (MCS) has been developed since the 1940s. Various MCS's has been proposed, developed, tested, and implemented in various hand rehabilitation devices for different purposes. This article presents a review of MCS in the existing hand rehabilitation devices. The MCS can be grouped into main groups, the non-pattern recognition and pattern recognition ones. In term of implementation, it can be classified as MCS for prosthetic and exoskeleton hand. Main challenges for MCS today is the robustness issue that hampers the implementation of MCS on the clinical application
    • …
    corecore