58,790 research outputs found
Continuous-variable optical quantum state tomography
This review covers latest developments in continuous-variable quantum-state
tomography of optical fields and photons, placing a special accent on its
practical aspects and applications in quantum information technology. Optical
homodyne tomography is reviewed as a method of reconstructing the state of
light in a given optical mode. A range of relevant practical topics are
discussed, such as state-reconstruction algorithms (with emphasis on the
maximum-likelihood technique), the technology of time-domain homodyne
detection, mode matching issues, and engineering of complex quantum states of
light. The paper also surveys quantum-state tomography for the transverse
spatial state (spatial mode) of the field in the special case of fields
containing precisely one photon.Comment: Finally, a revision! Comments to lvov(at)ucalgary.ca and
raymer(at)uoregon.edu are welcom
Data Compressed Photonic Time-Stretch Optical Coherence Tomography
Photonic time stretch enables real-time optical coherence tomography, but at the cost of extreme requirement for high-speed signal acquisition and massive data set. This work reports a data compressed real-time Fourier-domain optical coherence tomography based on photonics-assisted compressive sensing. Compression ratio of 66% is achieved
Optical coherence tomography: From physical principles to clinical applications
SummaryOptical coherence tomography is a new endocoronary imaging modality employing near infrared light, with very high axial resolution. We will review the physical principles, including the old time domain and newer Fourier domain generations, clinical applications, controversies and perspectives of optical coherence tomography
Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera
Polarization-sensitive optical coherence tomography can be used to measure the birefringence of biological tissue such as the human retina. Previous measurements with a time-domain polarization-sensitive optical coherence tomography system revealed that the birefringence of the human retinal nerve fiber layer is not constant, but varies as a function of location around the optic nerve head. Here we present a spectral-domain polarization-sensitive optical coherence tomography system that uses a spectrometer configuration with a single line scan camera and a Wollaston prism in the detection arm. Since only one camera has to be synchronized with other components in the system, the design is simplified considerably. This system is 60 times faster than a time-domain polarization-sensitive optical coherence tomography system. Data was acquired using concentric circular scans around the optic nerve head of a young healthy volunteer and the acquisition time for 12 circular scans was reduced from 72 s to 1.2 s. The acquired data sets demonstrate variations in retinal thickness and double pass phase retardation per unit depth that were similar to data from the same volunteer taken with a time-domain polarization-sensitive system. The double pass phase retardation per unit depth of the retinal nerve fiber layer varied between 0.18 and 0.40 degrees/μm, equivalent to a birefringence of 2.2 · 1
TDMS: an open source time domain Maxwell solver for simulating optical coherence tomography image formation
Realistic modelling of image formation in optical coherence tomography, which models light propagation in the sample using Maxwell’s equations, is useful for applications such as training researchers and clinicians, image interpretation and technique development. Such models, however, require specialised knowledge of numerical techniques for solving Maxwell’s equations, and for modelling optical systems. Here I present a freely available, open source package, aimed at making such simulations accessible to researchers throughout the optical coherence tomography community. Time Domain Maxwell Solver (TDMS) is based on the finite difference time domain (FDTD) and pseudo spectral time domain (PSTD) methods, and includes functionallity required to model optical systems typically found in OCT systems. TDMS includes several use case examples aimed at making it easy for users with limited background in simulation to use the package
Imaging workflow and calibration for CT-guided time-domain fluorescence tomography
In this study, several key optimization steps are outlined for a non-contact, time-correlated single photon counting small animal optical tomography system, using simultaneous collection of both fluorescence and transmittance data. The system is presented for time-domain image reconstruction in vivo, illustrating the sensitivity from single photon counting and the calibration steps needed to accurately process the data. In particular, laser time- and amplitude-referencing, detector and filter calibrations, and collection of a suitable instrument response function are all presented in the context of time-domain fluorescence tomography and a fully automated workflow is described. Preliminary phantom time-domain reconstructed images demonstrate the fidelity of the workflow for fluorescence tomography based on signal from multiple time gates
Optical chirality without optical activity: How surface plasmons give a twist to light
Light interacts differently with left and right handed three dimensional
chiral objects, like helices, and this leads to the phenomenon known as optical
activity. Here, by applying a polarization tomography, we show experimentally,
for the first time in the visible domain, that chirality has a different
optical manifestation for twisted planar nanostructured metallic objects acting
as isolated chiral metaobjects. Our analysis demonstrate how surface plasmons,
which are lossy bidimensional electromagnetic waves propagating on top of the
structure, can delocalize light information in the just precise way for giving
rise to this subtle effect.Comment: Opt. Express 16, 12559 (2008
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300nm SS-OCT system based on a swept laser with an 87nm tuning range
Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.
PurposeTo assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT).MethodsFifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias.ResultsICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771-0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95-3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04-3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12-1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (-0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers.ConclusionsBoth devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably
- …