1,556 research outputs found

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    Intervertebral disc characterization by shear wave elastography: an in-vitro preliminary study

    Get PDF
    Patient-specific numerical simulation of the spine is a useful tool both in clinic and research. While geometrical personalization of the spine is no more an issue, thanks to recent technological advances, non-invasive personalization of soft tissue’s mechanical properties remains a challenge. Ultrasound elastography is a relatively recent measurement technique allowing the evaluation of soft tissue’s elastic modulus through the measurement of shear wave speed (SWS). The aim of this study was to determine the feasibility of elastographic measurements in intervertebral disc (IVD). An in-vitro approach was chosen to test the hypothesis that SWS can be used to evaluate IVD mechanical properties and to assess measurement repeatability. Eleven oxtail IVDs were tested in compression to determine their stiffness and apparent elastic modulus at rest and at 400 N. Elastographic measurements were performed in these two conditions and compared to these mechanical parameters. The protocol was repeated six times to determine elastographic measurement repeatability. Average SWS over all samples was 5.3 ± 1.0 m/s, with a repeatability of 7 % at rest and 4.6 % at 400 N; stiffness and apparent elastic modulus were 266.3 ± 70.5 N/mm and 5.4 ± 1.1 MPa at rest, respectively, while at 400 N they were 781.0 ± 153.8 N/mm and 13.2 ± 2.4 MPa. Correlations were found between elastographic measurements and IVD mechanical properties; these preliminary results are promising for further in-vivo application.The authors are grateful to the ParisTech BiomecAM chair program on subject-specific musculoskeletal modelling for funding (with the support of Proteor, ParisTech and Yves Cotrel Foundations)

    Reducing radiation exposure in early-onset scoliosis surgery patients: novel use of ultrasonography to measure lengthening in magnetically-controlled growing rods

    Get PDF
    Abstract Background context Magnetically-controlled growing rod (MCGR) technology has been reported for the treatment of early-onset scoliosis (EOS). Such technology allows for regular and frequent outpatient rod distractions without the need for additional surgery. However, pre- and postdistraction spine radiographs are required to verify the amount of lengthening. This increased exposure to ionizing radiation in developing children significantly increases their risk profile for radiation-induced cancer and noncancerous morbidity. Purpose This study addressed the first and novel application and reliability of the use of ultrasonography, that has no ionizing radiation exposure, as an alternative to plain radiographs in the visualizing and confirming of rod distractions. Study design A prospective study. Patient sample Six EOS patients who underwent surgical treatment with MCGRs were prospectively recruited. Outcome measures Imaging measurements based on ultrasound and plain radiographs. Methods All patients were imaged via ultrasound, ease of rod identification was established, and the reliability and reproducibility of optimal reference point selection assessed blindly by three individuals. The clinical algorithm, using ultrasound, was subsequently implemented. Plain radiographs served as controls. Results Assessment of the rod's neck distance on ultrasound demonstrated a high degree of interrater reliability (a=0.99; p<.001). Intrarater reliability remained high on repeat measurements at different time intervals (a=1.00; p<.001). Satisfactory interrater reliability was noted when measuring the rod's neck (a=0.73; p=.010) and high reliability was noted in assessing the housing of the rod (a=0.85; p=.01) on plain radiographs. Under blinded conditions, 2 mm rod distraction measured on radiographs corresponded to 1.7 mm distraction on the ultrasound (standard deviation: 0.24 mm; p<.001). Subsequently, the clinical algorithm using ultrasound, instead of radiographs, has been successfully implemented. Conclusions This is the first study to report the use of a novel technique using noninvasive, nonionizing ultrasound to reliably document rod distractions in EOS patients. A high level of inter- and intrarater reliabilities were noted. More importantly, the use of ultrasonography may result in fewer whole spine radiographs from being taken in patients who have had MCGRs implanted for EOS; thereby decreasing their exposure to ionizing radiation and the potential risk of future radiation-induced diseases.postprin

    Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods

    Get PDF
    Current research has provided a more comprehensive understanding of Adolescent Idiopathic Scoliosis (AIS) as a three-dimensional spinal deformity, encompassing both lateral and rotational components. Apart from quantifying curve severity using the Cobb angle, vertebral rotation has become increasingly prominent in the study of scoliosis. It demonstrates significance in both preoperative and postoperative assessment, providing better appreciation of the impact of bracing or surgical interventions. In the past, the need for computer resources, digitizers and custom software limited studies of rotation to research performed after a patient left the scoliosis clinic. With advanced technology, however, rotation measurements are now more feasible. While numerous vertebral rotation measurement methods have been developed and tested, thorough comparisons of these are still relatively unexplored. This review discusses the advantages and disadvantages of six common measurement techniques based on technology most pertinent in clinical settings: radiography (Cobb, Nash-Moe, Perdriolle and Stokes' method) and computer tomography (CT) imaging (Aaro-Dahlborn and Ho's method). Better insight into the clinical suitability of rotation measurement methods currently available is presented, along with a discussion of critical concerns that should be addressed in future studies and development of new methods

    A Survey on 3D Ultrasound Reconstruction Techniques

    Get PDF
    This book chapter aims to discuss the 3D ultrasound reconstruction and visualization. First, the various types of 3D ultrasound system are reviewed, such as mechanical, 2D array, position tracking-based freehand, and untracked-based freehand. Second, the 3D ultrasound reconstruction technique or pipeline used by the current existing system, which includes the data acquisition, data preprocessing, reconstruction method and 3D visualization, is discussed. The reconstruction method and 3D visualization will be emphasized. The reconstruction method includes the pixel-based method, volume-based method, and function-based method, accompanied with their benefits and drawbacks. In the 3D visualization, methods such as multiplanar reformatting, volume rendering, and surface rendering are presented. Lastly, its application in the medical field is reviewed as well

    Integrated Approach for Cobb Angle Estimation in X-Ray C-Curve Scoliosis Using Image Processing and Inverse Cosine Law

    Get PDF
    Cobb angle is the angle subtended by the most tilted vertebrae. It represents the degree of the spinal curvature and has been used to diagnose scoliosis. The severity of the scoliosis based on the cobb angle will determine the guide treatment and surgical planning. Manual measurement of Cobb angle using protractor or semi-manual using ONIS software is quite time consuming, and it is subjected to variations in interobserver and intraobserver measurements. This research proposed an algorithm to determine the Cobb angle using image processing and inverse cosine methods. The raw samples of X-ray images were obtained from Pusat Kesihatan Universiti (PKU), UTHM. &nbsp;Several interviews were conducted with radiologist at Pantai Hospital for verification purpose. Gaussian blur and unsharp mask were initially applied for noise removal in the preprocessing step. Three points were marked at the vertebrae image to assist for centroid estimation using Haar Cascade. The Cobb angle was estimated by&nbsp;applying the triangle formula derived from the inverse cosine law. In comparison to semi-manual method (Onis Software), the proposed technique has an error of less than 5 % and computes the Cobb angle 3.28 times quicker. In the future, it is suggested to explore other techniques such as deep learning for alternative data analysis for Cobb angle estimation

    Accuracy of Pedicle Screw Placement Methods in Pediatrics and Adolescents Spinal Surgery: A Systematic Review and Meta-Analysis

    Get PDF
    STUDY DESIGN: Systematic review and meta-analysis. OBJECTIVE: Various methods of pedicle screw (PS) placement in spinal fusion surgery existed, which can be grouped into conventional freehand (FH), modified freehand (MF), and image-guided methods (including fluoroscopy-based navigation (FL), computed tomography-based navigation (CT-nav), robot-assisted (RA), and ultrasound-guided (UG)). However, the literature showed mixed findings regarding their accuracy and complications. This review aimed to discover which method of PS placement has the highest accuracy and lowest complication rate in pediatric and adolescent spinal fusion surgery. METHODS: A comprehensive search in MEDLINE (PubMed), EMBASE (OVID), CENTRAL, and Web of Science was conducted until May 2020 by 2 independent reviewers, followed by bias assessment with ROB 2 and ROBINS-I tools and quantification with meta-analysis. Overall evidence quality was determined with GRADE tool. RESULTS: Four RCTs and 2 quasi-RCTs/CCTs comprising 3,830 PS placed in 291 patients (4-22 years old) were analyzed. The lowest accuracy was found in FH (78.35%) while the highest accuracy was found in MF (95.86%). MF was more accurate than FH (OR 3.34 (95% CI, 2.33-4.79), P < .00 001, I2 = 0%). Three-dimensional printed drill template (as part of MF) was more accurate than FH (OR 3.10 (95% CI, 1.98-4.86), P < .00 001, I2 = 14%). Overall, complications occurred in 5.84% of the patients with 0.34% revision rate. Complication events in MF was lower compared to FH (OR 0.47 (95% CI, 0.10-2.15), P = .33, I2 = 0%). CONCLUSIONS: Meta-analysis shows that MF is more accurate than FH in pediatric and adolescent requiring PS placement for spinal fusion surgery
    corecore