138 research outputs found

    What is This?

    Get PDF
    Downloaded from ijr.sagepub.com at UNIV CALIFORNIA BERKELEY LIB on June 18, 2014Article Motion planning with sequential convex optimization and convex collision checkin

    Deep Reinforcement Learning in Surgical Robotics: Enhancing the Automation Level

    Full text link
    Surgical robotics is a rapidly evolving field that is transforming the landscape of surgeries. Surgical robots have been shown to enhance precision, minimize invasiveness, and alleviate surgeon fatigue. One promising area of research in surgical robotics is the use of reinforcement learning to enhance the automation level. Reinforcement learning is a type of machine learning that involves training an agent to make decisions based on rewards and punishments. This literature review aims to comprehensively analyze existing research on reinforcement learning in surgical robotics. The review identified various applications of reinforcement learning in surgical robotics, including pre-operative, intra-body, and percutaneous procedures, listed the typical studies, and compared their methodologies and results. The findings show that reinforcement learning has great potential to improve the autonomy of surgical robots. Reinforcement learning can teach robots to perform complex surgical tasks, such as suturing and tissue manipulation. It can also improve the accuracy and precision of surgical robots, making them more effective at performing surgeries

    Toward certifiable optimal motion planning for medical steerable needles

    Get PDF
    Medical steerable needles can follow 3D curvilinear trajectories to avoid anatomical obstacles and reach clinically significant targets inside the human body. Automating steerable needle procedures can enable physicians and patients to harness the full potential of steerable needles by maximally leveraging their steerability to safely and accurately reach targets for medical procedures such as biopsies. For the automation of medical procedures to be clinically accepted, it is critical from a patient care, safety, and regulatory perspective to certify the correctness and effectiveness of the planning algorithms involved in procedure automation. In this paper, we take an important step toward creating a certifiable optimal planner for steerable needles. We present an efficient, resolution-complete motion planner for steerable needles based on a novel adaptation of multi-resolution planning. This is the first motion planner for steerable needles that guarantees to compute in finite time an obstacle-avoiding plan (or notify the user that no such plan exists), under clinically appropriate assumptions. Based on this planner, we then develop the first resolution-optimal motion planner for steerable needles that further provides theoretical guarantees on the quality of the computed motion plan, that is, global optimality, in finite time. Compared to state-of-the-art steerable needle motion planners, we demonstrate with clinically realistic simulations that our planners not only provide theoretical guarantees but also have higher success rates, have lower computation times, and result in higher quality plans

    Integrating Optimization and Sampling for Robot Motion Planning with Applications in Healthcare

    Get PDF
    Robots deployed in human-centric environments, such as a person's home in a home-assistance setting or inside a person's body in a surgical setting, have the potential to have a large, positive impact on human quality of life. However, for robots to operate in such environments they must be able to move efficiently while avoiding colliding with obstacles such as objects in the person's home or sensitive anatomical structures in the person's body. Robot motion planning aims to compute safe and efficient motions for robots that avoid obstacles, but home assistance and surgical robots come with unique challenges that can make this difficult. For instance, many state of the art surgical robots have computationally expensive kinematic models, i.e., it can be computationally expensive to predict their shape as they move. Some of these robots have hybrid dynamics, i.e., they consist of multiple stages that behave differently. Additionally, it can be difficult to plan motions for robots while leveraging real-world sensor data, such as point clouds. In this dissertation, we demonstrate and empirically evaluate methods for overcoming these challenges to compute high-quality and safe motions for robots in home-assistance and surgical settings. First, we present a motion planning method for a continuum, parallel surgical manipulator that accounts for its computationally expensive kinematics. We then leverage this motion planner to optimize its kinematic design chosen prior to a surgical procedure. Next, we present a motion planning method for a 3-stage lung tumor biopsy robot that accounts for its hybrid dynamics and evaluate the robot and planner in simulation and in inflated porcine lung tissue. Next, we present a motion planning method for a home-assistance robot that leverages real-world, point-cloud obstacle representations. We then expand this method to work with a type of continuum surgical manipulator, a concentric tube robot, with point-cloud anatomical representations. Finally, we present a data-driven machine learning method for more accurately estimating the shape of concentric tube robots. By effectively addressing challenges associated with home assistance and surgical robots operating in human-centric environments, we take steps toward enabling robots to have a positive impact on human quality of life.Doctor of Philosoph

    Needle Steering in 3-D Via Rapid Replanning

    Get PDF
    Steerable needles have the potential to improve the effectiveness of needle-based clinical procedures such as biopsy and drug delivery by improving targeting accuracy and reaching previously inaccessible targets that are behind sensitive or impenetrable anatomical regions. We present a new needle steering system capable of automatically reaching targets in 3-D environments while avoiding obstacles and compensating for real-world uncertainties. Given a specification of anatomical obstacles and a clinical target (e.g., from preoperative medical images), our system plans and controls needle motion in a closed-loop fashion under sensory feedback to optimize a clinical metric. We unify planning and control using a new fast algorithm that continuously replans the needle motion. Our rapid replanning approach is enabled by an efficient sampling-based rapidly exploring random tree (RRT) planner that achieves orders-of-magnitude reduction in computation time compared with prior 3-D approaches by incorporating variable curvature kinematics and a novel distance metric for planning. Our system uses an electromagnetic tracking system to sense the state of the needle tip during the procedure. We experimentally evaluate our needle steering system using tissue phantoms and animal tissue ex vivo. We demonstrate that our rapid replanning strategy successfully guides the needle around obstacles to desired 3-D targets with an average error of less than 3 mm

    Closed-Loop Planning and Control of Steerable Medical Needles

    Get PDF
    Steerable needles have the potential to increase the effectiveness of needle-based clinical procedures such as biopsy, drug delivery, and radioactive seed implantation for cancer treatment. These needles can trace curved paths when inserted into tissue, thereby increasing maneuverability and targeting accuracy while reaching previously inaccessible targets that are behind sensitive or impenetrable anatomical regions. Guiding these flexible needles along an intended path requires continuously inserting and twisting the needle at its base, which is not intuitive for a human operator. In addition, the needle often deviates from its intended trajectory due to factors such as tissue deformation, needle-tissue interaction, noisy actuation and sensing, modeling errors, and involuntary patient motions. These challenges can be addressed with the assistance of robotic systems that automatically compensate for these perturbations by performing motion planning and feedback control of the needle in a closed-loop fashion under sensory feedback. We present two approaches for efficient closed-loop guidance of steerable needles to targets within clinically acceptable accuracy while safely avoiding sensitive or impenetrable anatomical structures. The first approach uses a fast motion planning algorithm that unifies planning and control by continuously replanning, enabling correction for perturbations as they occur. We evaluate our method using a needle steering system in phantom and ex vivo animal tissues. The second approach integrates motion planning and feedback control of steerable needles in highly deformable environments. We demonstrate that this approach significantly improves the probability of success compared to prior approaches that either consider uncertainty or deformations but not both simultaneously. We also propose a data-driven method to estimate parameters of stochastic models of steerable needle motion. These models can be used to create realistic medical simulators for clinicians wanting to train for steerable needle procedures and to improve the effectiveness of existing planning and control methods. This dissertation advances the state of the art in planning and control of steerable needles and is an important step towards realizing needle steering in clinical practice. The methods developed in this dissertation also generalize to important applications beyond medical needle steering, such as manipulating deformable objects and control of mobile robots.Doctor of Philosoph

    Automatic optimized 3D path planner for steerable catheters with heuristic search and uncertainty tolerance

    Get PDF
    In this paper, an automatic planner for minimally invasive neurosurgery is presented. The solution can provide the surgeon with the best path to connect a user-defined entry point with a target in accordance with specific optimality criteria guaranteeing the clearance from obstacles which can be found along the insertion pathway. The method is integrated onto the EDEN2020∗ programmable bevel-tip needle, a multi-segment steerable probe intended to be used to perform drug delivery for glioblastomas treatment. A sample-based heuristic search inspired to the BIT* algorithm is used to define the optimal solution in terms of path length, followed by a smoothing phase required to meet the kinematic constraint of the catheter. To account for inaccuracies in catheter modeling, which could de- termine unexpected control errors over the insertion procedure, an uncertainty margin is defined so that to include a further level of safety for the planning algorithm. The feasibility of the proposed solution was demonstrated by testing the method in simulated neurosurgical scenarios with different degree of obstacles occupancy and against other sample-based algorithms present in literature: RRT, RRT* and an enhanced version of the RRT-Connect
    • …
    corecore