1,588 research outputs found

    Automatic Mode Switching in Atrial Fibrillation

    Get PDF
    Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs

    A Review of Atrial Fibrillation Detection Methods as a Service

    Get PDF
    Atrial Fibrillation (AF) is a common heart arrhythmia that often goes undetected, and even if it is detected, managing the condition may be challenging. In this paper, we review how the RR interval and Electrocardiogram (ECG) signals, incorporated into a monitoring system, can be useful to track AF events. Were such an automated system to be implemented, it could be used to help manage AF and thereby reduce patient morbidity and mortality. The main impetus behind the idea of developing a service is that a greater data volume analyzed can lead to better patient outcomes. Based on the literature review, which we present herein, we introduce the methods that can be used to detect AF efficiently and automatically via the RR interval and ECG signals. A cardiovascular disease monitoring service that incorporates one or multiple of these detection methods could extend event observation to all times, and could therefore become useful to establish any AF occurrence. The development of an automated and efficient method that monitors AF in real time would likely become a key component for meeting public health goals regarding the reduction of fatalities caused by the disease. Yet, at present, significant technological and regulatory obstacles remain, which prevent the development of any proposed system. Establishment of the scientific foundation for monitoring is important to provide effective service to patients and healthcare professionals

    Detection of atrial fibrillation episodes in long-term heart rhythm signals using a support vector machine

    Get PDF
    Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.Web of Science203art. no. 76

    Evolutionary Optimization of Atrial Fibrillation Diagnostic Algorithms

    Get PDF
    The goal of this research is to introduce an improved method for detecting atrial fibrillation (AF). The foundation of our algorithm is the irregularity of the RR intervals in the electrocardiogram (ECG) signal, and their correlation with AF. Three statistical techniques, including root mean squares of successive differences (RMSSD), turning points ratio (TPR), and Shannon entropy (SE), are used to detect RR interval irregularity. We use the Massachusetts Institution of Technology / Beth Israel Hospital (MIT-BIH) atrial fibrillation databases and their annotations to tune the parameters of the statistical methods by biogeography-based optimization (BBO), which is an evolutionary optimization algorithm. We trained each statistical method to diagnose AF on each database. Then each trained method was tested on the rest of the databases. We were able to obtain accuracy levels as high as 99 for the detection of AF in the trained databases. We obtained accuracy levels of up to 75 in the tested database

    Evolutionary Optimization of Atrial Fibrillation Diagnostic Algorithms

    Get PDF
    The goal of this research is to introduce an improved method for detecting atrial fibrillation (AF). The foundation of our algorithm is the irregularity of the RR intervals in the electrocardiogram (ECG) signal, and their correlation with AF. Three statistical techniques, including root mean squares of successive differences (RMSSD), turning points ratio (TPR), and Shannon entropy (SE), are used to detect RR interval irregularity. We use the Massachusetts Institution of Technology / Beth Israel Hospital (MIT-BIH) atrial fibrillation databases and their annotations to tune the parameters of the statistical methods by biogeography-based optimization (BBO), which is an evolutionary optimization algorithm. We trained each statistical method to diagnose AF on each database. Then each trained method was tested on the rest of the databases. We were able to obtain accuracy levels as high as 99 for the detection of AF in the trained databases. We obtained accuracy levels of up to 75 in the tested database

    Automatic mode switching in atrial fibrillation

    Get PDF
    Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs
    corecore