1,462 research outputs found
Joint segmentation and classification of retinal arteries/veins from fundus images
Objective Automatic artery/vein (A/V) segmentation from fundus images is
required to track blood vessel changes occurring with many pathologies
including retinopathy and cardiovascular pathologies. One of the clinical
measures that quantifies vessel changes is the arterio-venous ratio (AVR) which
represents the ratio between artery and vein diameters. This measure
significantly depends on the accuracy of vessel segmentation and classification
into arteries and veins. This paper proposes a fast, novel method for semantic
A/V segmentation combining deep learning and graph propagation.
Methods A convolutional neural network (CNN) is proposed to jointly segment
and classify vessels into arteries and veins. The initial CNN labeling is
propagated through a graph representation of the retinal vasculature, whose
nodes are defined as the vessel branches and edges are weighted by the cost of
linking pairs of branches. To efficiently propagate the labels, the graph is
simplified into its minimum spanning tree.
Results The method achieves an accuracy of 94.8% for vessels segmentation.
The A/V classification achieves a specificity of 92.9% with a sensitivity of
93.7% on the CT-DRIVE database compared to the state-of-the-art-specificity and
sensitivity, both of 91.7%.
Conclusion The results show that our method outperforms the leading previous
works on a public dataset for A/V classification and is by far the fastest.
Significance The proposed global AVR calculated on the whole fundus image
using our automatic A/V segmentation method can better track vessel changes
associated to diabetic retinopathy than the standard local AVR calculated only
around the optic disc.Comment: Preprint accepted in Artificial Intelligence in Medicin
Retinal Vessel Segmentation Using the 2-D Morlet Wavelet and Supervised Classification
We present a method for automated segmentation of the vasculature in retinal
images. The method produces segmentations by classifying each image pixel as
vessel or non-vessel, based on the pixel's feature vector. Feature vectors are
composed of the pixel's intensity and continuous two-dimensional Morlet wavelet
transform responses taken at multiple scales. The Morlet wavelet is capable of
tuning to specific frequencies, thus allowing noise filtering and vessel
enhancement in a single step. We use a Bayesian classifier with
class-conditional probability density functions (likelihoods) described as
Gaussian mixtures, yielding a fast classification, while being able to model
complex decision surfaces and compare its performance with the linear minimum
squared error classifier. The probability distributions are estimated based on
a training set of labeled pixels obtained from manual segmentations. The
method's performance is evaluated on publicly available DRIVE and STARE
databases of manually labeled non-mydriatic images. On the DRIVE database, it
achieves an area under the receiver operating characteristic (ROC) curve of
0.9598, being slightly superior than that presented by the method of Staal et
al.Comment: 9 pages, 7 figures and 1 table. Accepted for publication in IEEE
Trans Med Imag; added copyright notic
Automated Fovea Detection Based on Unsupervised Retinal Vessel Segmentation Method
The Computer Assisted Diagnosis systems could save workloads and give objective diagnostic to ophthalmologists. At first level of automated screening of systems feature extraction is the fundamental step. One of these retinal features is the fovea. The fovea is a small fossa on the fundus, which is represented by a deep-red or red-brown color in color retinal images. By observing retinal images, it appears that the main vessels diverge from the optic nerve head and follow a specific course that can be geometrically modeled as a parabola, with a common vertex inside the optic nerve head and the fovea located along the apex of this parabola curve. Therefore, based on this assumption, the main retinal blood vessels are segmented and fitted to a parabolic model. With respect to the core vascular structure, we can thus detect fovea in the fundus images. For the vessel segmentation, our algorithm addresses the image locally where homogeneity of features is more likely to occur. The algorithm is composed of 4 steps: multi-overlapping windows, local Radon transform, vessel validation, and parabolic fitting. In order to extract blood vessels, sub-vessels should be extracted in local windows. The high contrast between blood vessels and image background in the images cause the vessels to be associated with peaks in the Radon space. The largest vessels, using a high threshold of the Radon transform, determines the main course or overall configuration of the blood vessels which when fitted to a parabola, leads to the future localization of the fovea. In effect, with an accurate fit, the fovea normally lies along the slope joining the vertex and the focus. The darkest region along this line is the indicative of the fovea. To evaluate our method, we used 220 fundus images from a rural database (MUMS-DB) and one public one (DRIVE). The results show that, among 20 images of the first public database (DRIVE) we detected fovea in 85% of them. Also for the MUMS-DB database among 200 images we detect fovea correctly in 83% on them
Recommended from our members
M2U-net: Effective and efficient retinal vessel segmentation for real-world applications
In this paper, we present a novel neural network architecture for retinal vessel segmentation that improves over the state of the art on two benchmark datasets, is the first to run in real time on high resolution images, and its small memory and processing requirements make it deployable in mobile and embedded systems. The M2U-Net has a new encoder-decoder architecture that is inspired by the U-Net. It adds pretrained components of MobileNetV2 in the encoder part and novel contractive bottleneck blocks in the decoder part that, combined with bilinear upsampling, drastically reduce the parameter count to 0.55M compared to 31.03M in the original U-Net. We have evaluated its performance against a wide body of previously published results on three public datasets. On two of them, the M2U-Net achieves new state-of-the-art performance by a considerable margin. When implemented on a GPU, our method is the first to achieve real-time inference speeds on high-resolution fundus images. We also implemented our proposed network on an ARM-based embedded system where it segments images in between 0.6 and 15 sec, depending on the resolution. Thus, the M2U-Net enables a number of applications of retinal vessel structure extraction, such as early diagnosis of eye diseases, retinal biometric authentication systems, and robot assisted microsurgery
Deep Learning in Cardiology
The medical field is creating large amount of data that physicians are unable
to decipher and use efficiently. Moreover, rule-based expert systems are
inefficient in solving complicated medical tasks or for creating insights using
big data. Deep learning has emerged as a more accurate and effective technology
in a wide range of medical problems such as diagnosis, prediction and
intervention. Deep learning is a representation learning method that consists
of layers that transform the data non-linearly, thus, revealing hierarchical
relationships and structures. In this review we survey deep learning
application papers that use structured data, signal and imaging modalities from
cardiology. We discuss the advantages and limitations of applying deep learning
in cardiology that also apply in medicine in general, while proposing certain
directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table
Accurate and reliable segmentation of the optic disc in digital fundus images
We describe a complete pipeline for the detection and accurate automatic segmentation of the optic disc in digital fundus images. This procedure provides separation of vascular information and accurate inpainting of vessel-removed images, symmetry-based optic disc localization, and fitting of incrementally complex contour models at increasing resolutions using information related to inpainted images and vessel masks. Validation experiments, performed on a large dataset of images of healthy and pathological eyes, annotated by experts and partially graded with a quality label, demonstrate the good performances of the proposed approach. The method is able to detect the optic disc and trace its contours better than the other systems presented in the literature and tested on the same data. The average error in the obtained contour masks is reasonably close to the interoperator errors and suitable for practical applications. The optic disc segmentation pipeline is currently integrated in a complete software suite for the semiautomatic quantification of retinal vessel properties from fundus camera images (VAMPIRE)
Automatic extraction of retinal features from colour retinal images for glaucoma diagnosis: a review
Glaucoma is a group of eye diseases that have common traits such as, high eye pressure, damage to the Optic Nerve Head and gradual vision loss. It affects peripheral vision and eventually leads to blindness if left untreated. The current common methods of pre-diagnosis of Glaucoma include measurement of Intra-Ocular Pressure (IOP) using Tonometer, Pachymetry, Gonioscopy; which are performed manually by the clinicians. These tests are usually followed by Optic Nerve Head (ONH) Appearance examination for the confirmed diagnosis of Glaucoma. The diagnoses require regular monitoring, which is costly and time consuming. The accuracy and reliability of diagnosis is limited by the domain knowledge of different ophthalmologists. Therefore automatic diagnosis of Glaucoma attracts a lot of attention.This paper surveys the state-of-the-art of automatic extraction of anatomical features from retinal images to assist early diagnosis of the Glaucoma. We have conducted critical evaluation of the existing automatic extraction methods based on features including Optic Cup to Disc Ratio (CDR), Retinal Nerve Fibre Layer (RNFL), Peripapillary Atrophy (PPA), Neuroretinal Rim Notching, Vasculature Shift, etc., which adds value on efficient feature extraction related to Glaucoma diagnosis. © 2013 Elsevier Ltd
- …