7,676 research outputs found
Circular polarization measurement in millimeter-wavelength spectral-line VLBI observations
This paper considers the problem of accurate measurement of circular
polarization in imaging spectral-line VLBI observations in the lambda=7 mm and
lambda=3 mm wavelength bands. This capability is especially valuable for the
full observational study of compact, polarized SiO maser components in the
near-circumstellar environment of late-type, evolved stars. Circular VLBI
polarimetry provides important constraints on SiO maser astrophysics, including
the theory of polarized maser emission transport, and on the strength and
distribution of the stellar magnetic field and its dynamical role in this
critical circumstellar region. We perform an analysis here of the data model
containing the instrumental factors that limit the accuracy of circular
polarization measurements in such observations, and present a corresponding
data reduction algorithm for their correction. The algorithm is an enhancement
of existing spectral line VLBI polarimetry methods using autocorrelation data
for calibration, but with innovations in bandpass determination,
autocorrelation polarization self-calibration, and general optimizations for
the case of low SNR, as applicable at these wavelengths. We present an example
data reduction at mm and derive an estimate of the predicted
accuracy of the method of m_c < 0.5% or better at lambda=7 mm and m_c < 0.5-1%
or better at lambda=3 mm. Both the strengths and weaknesses of the proposed
algorithm are discussed, along with suggestions for future work.Comment: 23 pages, 13 figure
On Measuring Accurate 21-cm Line Profiles with the Robert C. Byrd Green Bank Telescope
We use observational data to show that 21 cm line profiles measured with the
Green Bank Telescope (GBT) are subject to significant inaccuracy. These include
~10% errors in the calibrated gain and significant contribution from distant
sidelobes. In addition, there are ~60% variations between the GBT and
Leiden/Argentine/Bonn 21 cm line profile intensities, which probably occur
because of the high main-beam efficiency of the GBT. Stokes V profiles from the
GBT contain inaccuracies that are related to the distant sidelobes.
We illustrate these problems, define physically motivated components for the
sidelobes, and provide numerical results showing the inaccuracies. We provide a
correction scheme for Stokes I 21 cm line profiles that is fairly successful
and provide some rule-of-thumb comments concerning the accuracy of Stokes V
profiles.Comment: 39 pages, 20 figures, accepted for publication in PAS
A radio continuum survey of the southern sky at 1420 MHz. Observations and data reduction
We describe the equipment, observational method and reduction procedure of an
absolutely calibrated radio continuum survey of the South Celestial Hemisphere
at a frequency of 1420 MHz. These observations cover the area 0h < R.A. < 24h
for declinations less than -10 degree. The sensitivity is about 50 mK T_B (full
beam brightness) and the angular resolution (HPBW) is 35.4', which matches the
existing northern sky survey at the same frequency.Comment: 9 pages with 9 figures, A&A, in pres
The QUIET Instrument
The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the
Cosmic Microwave Background, targeting the imprint of inflationary
gravitational waves at large angular scales (~ 1 degree). Between 2008 October
and 2010 December, two independent receiver arrays were deployed sequentially
on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal
planes use a highly compact design based on High Electron Mobility Transistors
(HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U,
and I in a single module. The 17-element Q-band polarimeter array, with a
central frequency of 43.1 GHz, has the best sensitivity (69 uK sqrt(s)) and the
lowest instrumental systematic errors ever achieved in this band, contributing
to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter
array has a sensitivity of 87 uK sqrt(s) at a central frequency of 94.5 GHz. It
has the lowest systematic errors to date, contributing at r < 0.01. The two
arrays together cover multipoles in the range l= 25-975. These are the largest
HEMT-based arrays deployed to date. This article describes the design,
calibration, performance of, and sources of systematic error for the
instrument
- …