92,149 research outputs found

    Satellite Image Denoising Using Local Spayed and Optimized Center Pixel Weights

    Get PDF
    Now a day’s digital image processing applications are widely used in various fields such as medical, military, satellite, remote sensing and even web applications also. In any application image denoising is a challenging task because noise removal will increase the digital quality of an image and will improve the perceptual visual quality. In this paper we proposed a new method “local spayed and optimized center pixel weights (LSOCPW) with non local means” to improve the denoising performance of digital color image sequences. Simulation results show that the proposed method has given the better performance when compared to the existing algorithms in terms of peak signal to noise ratio (PSNR) and mean square error (MSE).DOI:http://dx.doi.org/10.11591/ijece.v4i5.662

    Design and implementation a prototype system for fusion image by using SWT-PCA algorithm with FPGA technique

    Get PDF
    The technology of fusion image is dominance strongly over domain research for recent years, the techniques of fusion have various applications in real time used and proposed such as purpose of military and remote sensing etc.,the fusion image is very efficient in processing of digital image. Single image produced from two images or more information of relevant combining process results from multi sensor fusion image. FPGA is the best implementation types of most technology enabling wide spread.This device works with modern versions for different critical characteristics same huge number of elements logic in order to permit complex algorithm implemented. In this paper,filters are designed and implemented in FPGA utilized for disease specified detection from images CT/MRI scanned where the samples are taken for human's brain with various medical images and the processing of fusion employed by using technique Stationary Wavelet Transform and Principal Component Analysis (SWT-PCA). Accuracy image output increases when implemented this technique and that was done by sampling down eliminating where effects blurring and artifacts doesn't influenced. The algorithm of SWT-PCA parameters quality measurements like NCC,MSE ,PSNR, coefficients and Eigen values.The advantages significant of this system that provide real time, time rapid to market and portability beside the change parametric continuing in the DWT transform. The designed and simulation of module proposed system has been done by using MATLAB simulink and blocks generator system, Xilinx synthesized with synthesis tool (XST) and implemented in XilinxSpartan 6-SP605 device

    J-PET Framework: Software platform for PET tomography data reconstruction and analysis

    Get PDF
    J-PET Framework is an open-source software platform for data analysis, written in C++ and based on the ROOT package. It provides a common environment for implementation of reconstruction, calibration and filtering procedures, as well as for user-level analyses of Positron Emission Tomography data. The library contains a set of building blocks that can be combined by users with even little programming experience, into chains of processing tasks through a convenient, simple and well-documented API. The generic input-output interface allows processing the data from various sources: low-level data from the tomography acquisition system or from diagnostic setups such as digital oscilloscopes, as well as high-level tomography structures e.g. sinograms or a list of lines-of-response. Moreover, the environment can be interfaced with Monte Carlo simulation packages such as GEANT and GATE, which are commonly used in the medical scientific community.Comment: 14 pages, 5 figure

    2D-3D registration of CT vertebra volume to fluoroscopy projection: A calibration model assessment (doi:10.1155/2010/806094)

    Get PDF
    This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digitally Reconstructed Radiographs (obtained from the CT volume) and real fluoroscopic projection. X-ray energy correction was performed. To assess the method a calibration model was realised a sheep dry vertebra was rigidly fixed to a frame of reference including metallic markers. Accurate measurement of 3D orientation was obtained via single-camera calibration of the markers and held as true 3D vertebra position; then, vertebra 3D pose was estimated and results compared. Error analysis revealed accuracy of the order of 0.1 degree for the rotation angles of about 1?mm for displacements parallel to the fluoroscopic plane, and of order of 10?mm for the orthogonal displacement.<br/
    corecore