3,025 research outputs found

    On including quality in applied automatic gait recognition

    No full text
    Many gait recognition approaches use silhouette data. Imperfections in silhouette extraction have a negative effect on the performance of a gait recognition system. In this paper we extend quality metrics for gait recognition and evaluate new ways of using quality to improve a recognition system. We demonstrate use of quality to improve silhouette data and select gait cycles of best quality. The potential of the new approaches has been demonstrated experimentally on a challenging dataset, showing how recognition capability can be dramatically improved. Our practical study also shows that acquiring samples of adequate quality in arbitrary environments is difficult and that including quality analysis can improve performance markedly

    Silhouette-based gait recognition using Procrustes shape analysis and elliptic Fourier descriptors

    Get PDF
    This paper presents a gait recognition method which combines spatio-temporal motion characteristics, statistical and physical parameters (referred to as STM-SPP) of a human subject for its classification by analysing shape of the subject's silhouette contours using Procrustes shape analysis (PSA) and elliptic Fourier descriptors (EFDs). STM-SPP uses spatio-temporal gait characteristics and physical parameters of human body to resolve similar dissimilarity scores between probe and gallery sequences obtained by PSA. A part-based shape analysis using EFDs is also introduced to achieve robustness against carrying conditions. The classification results by PSA and EFDs are combined, resolving tie in ranking using contour matching based on Hu moments. Experimental results show STM-SPP outperforms several silhouette-based gait recognition methods

    Principal component analysis for human gait recognition system

    Get PDF
    This paper represents a method for Human Recognition system using Principal Component Analysis. Human Gait recognition works on the gait of walking subjects to identify people without them knowing or without their permission. The initial step in this kind of system is to generate silhouette frames of walking human. A number of features couldb be exytacted from these frames such as centriod ratio, heifht, width and orientation. The Principal Component Analysis (PCA) is used for the extracted features to condense the information and produces the main components that can represent the gait sequences for each waiking human. In the testing phase, the generated gait sequences are recognized by using a minimum distance classifier based on eluclidean distance matched with the one that already exist in the database used to identify walking subject

    Gait recognition based on shape and motion analysis of silhouette contours

    Get PDF
    This paper presents a three-phase gait recognition method that analyses the spatio-temporal shape and dynamic motion (STS-DM) characteristics of a human subjectā€™s silhouettes to identify the subject in the presence of most of the challenging factors that affect existing gait recognition systems. In phase 1, phase-weighted magnitude spectra of the Fourier descriptor of the silhouette contours at ten phases of a gait period are used to analyse the spatio-temporal changes of the subjectā€™s shape. A component-based Fourier descriptor based on anatomical studies of human body is used to achieve robustness against shape variations caused by all common types of small carrying conditions with folded hands, at the subjectā€™s back and in upright position. In phase 2, a full-body shape and motion analysis is performed by fitting ellipses to contour segments of ten phases of a gait period and using a histogram matching with Bhattacharyya distance of parameters of the ellipses as dissimilarity scores. In phase 3, dynamic time warping is used to analyse the angular rotation pattern of the subjectā€™s leading knee with a consideration of arm-swing over a gait period to achieve identification that is invariant to walking speed, limited clothing variations, hair style changes and shadows under feet. The match scores generated in the three phases are fused using weight-based score-level fusion for robust identification in the presence of missing and distorted frames, and occlusion in the scene. Experimental analyses on various publicly available data sets show that STS-DM outperforms several state-of-the-art gait recognition methods

    On Acquisition and Analysis of a Dataset Comprising of Gait, Ear and Semantic data

    No full text
    In outdoor scenarios such as surveillance where there is very little control over the environments, complex computer vision algorithms are often required for analysis. However constrained environments, such as walkways in airports where the surroundings and the path taken by individuals can be controlled, provide an ideal application for such systems. Figure 1.1 depicts an idealised constrained environment. The path taken by the subject is restricted to a narrow path and once inside is in a volume where lighting and other conditions are controlled to facilitate biometric analysis. The ability to control the surroundings and the flow of people greatly simplifes the computer vision task, compared to typical unconstrained environments. Even though biometric datasets with greater than one hundred people are increasingly common, there is still very little known about the inter and intra-subject variation in many biometrics. This information is essential to estimate the recognition capability and limits of automatic recognition systems. In order to accurately estimate the inter- and the intra- class variance, substantially larger datasets are required [40]. Covariates such as facial expression, headwear, footwear type, surface type and carried items are attracting increasing attention; although considering the potentially large impact on an individuals biometrics, large trials need to be conducted to establish how much variance results. This chapter is the first description of the multibiometric data acquired using the University of Southampton's Multi-Biometric Tunnel [26, 37]; a biometric portal using automatic gait, face and ear recognition for identification purposes. The tunnel provides a constrained environment and is ideal for use in high throughput security scenarios and for the collection of large datasets. We describe the current state of data acquisition of face, gait, ear, and semantic data and present early results showing the quality and range of data that has been collected. The main novelties of this dataset in comparison with other multi-biometric datasets are: 1. gait data exists for multiple views and is synchronised, allowing 3D reconstruction and analysis; 2. the face data is a sequence of images allowing for face recognition in video; 3. the ear data is acquired in a relatively unconstrained environment, as a subject walks past; and 4. the semantic data is considerably more extensive than has been available previously. We shall aim to show the advantages of this new data in biometric analysis, though the scope for such analysis is considerably greater than time and space allows for here

    Analysis of Most Important Parts for Silhouette-Based Gait Recognition

    Get PDF

    Multi-Modal Human Authentication Using Silhouettes, Gait and RGB

    Full text link
    Whole-body-based human authentication is a promising approach for remote biometrics scenarios. Current literature focuses on either body recognition based on RGB images or gait recognition based on body shapes and walking patterns; both have their advantages and drawbacks. In this work, we propose Dual-Modal Ensemble (DME), which combines both RGB and silhouette data to achieve more robust performances for indoor and outdoor whole-body based recognition. Within DME, we propose GaitPattern, which is inspired by the double helical gait pattern used in traditional gait analysis. The GaitPattern contributes to robust identification performance over a large range of viewing angles. Extensive experimental results on the CASIA-B dataset demonstrate that the proposed method outperforms state-of-the-art recognition systems. We also provide experimental results using the newly collected BRIAR dataset

    Covariate Analysis for View-point Independent Gait Recognition

    No full text
    Many studies have shown that gait can be deployed as a biometric. Few of these have addressed the effects of view-point and covariate factors on the recognition process. We describe the first analysis which combines view-point invariance for gait recognition which is based on a model-based pose estimation approach from a single un-calibrated camera. A set of experiments are carried out to explore how such factors including clothing, carrying conditions and view-point can affect the identification process using gait. Based on a covariate-based probe dataset of over 270 samples, a recognition rate of 73.4% is achieved using the KNN classifier. This confirms that people identification using dynamic gait features is still perceivable with better recognition rate even under the different covariate factors. As such, this is an important step in translating research from the laboratory to a surveillance environment
    • ā€¦
    corecore