154 research outputs found

    Harmonic Reduction of a Single-Phase Multilevel Inverter Using Genetic Algorithm and Particle Swarm Optimization

    Get PDF
    Power inverter play an important role in power system especially with its capability on reducing system size and increase efficiently. The recent research trends of power electronic system are focusing on multilevel inverter topics in optimization on voltage output, reducing the total harmonics distortion, modulation technique, and switching configuration. The research emphasizes the optimization with a fundamental switching frequency method that is the optimized harmonic stepped waveform (OHSW) modulation method. The selective harmonic elimination (SHE) calculation has adapted with genetic algorithm (GA) and particle swarm optimization (PSO) in order to speed up the calculation. Both bioinspired algorithms are compared in terms of total harmonic distortion (THD) and selective harmonic elimination for both equal and unequal sources. The overall result showed that both algorithms have high accuracy in solving the nonlinear equation. However, the genetic algorithm showed better output quality in terms of selective harmonic elimination which overall no exceeding 0.4%. Particle swarm optimization shows strength in finding the best total harmonic distortion where in seven-level cascaded H-bridge multilevel inverter (m=0.8) shows 6.8% only as compared to genetic algorithm. Simulation for three-level, five-level, and seven-level for each multilevel inverter at different circumferences had been done in this research. The result draws out a conclusion where the possibility of having a filterless high-efficient inverter can be achieved

    Dragonfly algorithm-based optimization for selective harmonics elimination in cascaded H-bridge multilevel inverters with statistical comparison

    Get PDF
    Harmonics worsen the quality of electrical signals, hence, there is a need to eliminate them. The test objects under discussion are single-phase versions of cascaded H-bridge (CHB) multilevel inverters (MLIs) whose switching angles are optimized to eliminate specific harmonics. The Dragonfly Algorithm (DA) is used to eradicate low-order harmonics, and its statistical performance is compared to that of many other optimization techniques, including Particle Swarm Optimization (PSO), Accelerated Particle Swarm Optimization (APSO), Differential Evolution (DE), and Grey Wolf Optimization (GWO). Various scenarios of the algorithms’ search agent population for inverters with seven, nine, and eleven levels of output voltages are comprehensively addressed in this research. No algorithm shows total dominance in every scenario. The DA is least impacted by the change in dimensions of the narrated problem

    Swarm Optimization-Based Modified Selective Harmonic Elimination PWM Technique Application in Symmetrical H-Bridge Type Multilevel Inverters

    Get PDF
    The problem of elimination of harmonics and the need of a large number of switches in multilevel inverters (MLIs) have been a hot topic of research over the last decades. In this paper, a new variant swarm optimization (SO) based selective harmonic elimination (SHE) technique is described to minimize harmonics in MLIs, which is a complex optimization problem involving non-linear transcendental equation. Optimum switching angles are calculated by the proposed algorithms considering minimum total harmonic distortion (THD) and the best results are taken for controlling the operation of MLIs. The performance of the proposed algorithm is compared with the genetic algorithm (GA). Conventional MLIs have some disadvantages such as the requirement of a large number of circuit components, complex control, and voltage balancing problems. A novel seven-level reduced switch multilevel inverter (RS MLI) is proposed in this paper to recoup the need of a large number of switches. Matlab/Simulink software is used for the simulation of two symmetrical topologies, i.e., a seven-level cascaded H-bridge multilevel inverter (CHB MLI) and a seven-level (RS MLI). Simulation results are validated by developing a prototype of both MLIs. The enhancement of the output voltage waveform confirms the effectiveness of the proposed SO SHE approach

    Coconut dehusker machine

    Get PDF
    Generally, coconut is dehusked manually using either a machete or a spike. These methods required skill labor and tiring to use. Attempts made so far in development of dehusking tools have been only partially successful and not effective in replacing manual methods. The reasons quoted for the failure of these tools include unsatisfactory and incomplete dehusking, breakage of the coconut shell while dehusking, spoilage of useful coir, greater effort needed than manual methods, etc

    Time-Domain Minimization of Voltage and Current Total Harmonic Distortion for a Single-Phase Multilevel Inverter with a Staircase Modulation

    Get PDF
    This paper presents the optimization technique for minimizing the voltage and current total harmonic distortion (THD) in a single-phase multilevel inverter controlled by staircase modulation. The previously reported research generally considered the optimal THD problem in the frequency domain, taking into account a limited harmonic number. The novelty of the suggested approach is that voltage and current minimal THD problems are being formulated in the time domain as constrained optimization ones, making it possible to determine the optimal switching angles. In this way, all switching harmonics can be considered. The target function expression becomes very compact and existing efficient solvers for this kind of optimization problems can find a solution in negligible processor time. Current THD is understood as voltage frequency weighted THD that assumes pure inductive load—this approximation is practically accurate for inductively dominant RL-loads. In this study, the optimal switching angles and respective minimal THD values were obtained for different inverter level counts and overall fundamental voltage magnitude (modulation index) dynamic range. Developments are easily modified to cover multilevel inverter grid-connected applications. The results have been verified by experimental tests

    Pengaruh adukan dan kepekatan partikel silicon karbida sebagai penguat terhadap kelakuan salutan komposit matriks nikel

    Get PDF
    Affordable quality housing is vital in developing countries to meet its growing population. Development of a new cost effective system is crucial to fulfill these demands. In view of this, a study is carried out to develope a Precast Lightweight Foamed Concrete Sandwich Panel (PLFP), as a new affordable building system. Experimental investigation and finite element analysis to study the structural behaviour of the PLFP panel under axial load is undertaken. The panel consists of two foamed concrete wythes and a polystyrene insulation layer in between the wythes. The wythes are reinforced with high tensile steel bars and tied up to each other through the polystyrene layer by steel shear connectors bent at an angle of 45º. The panels are loaded with axial load until failure. The ultimate load carrying capacity, load-lateral deflection profile, strain distributions, and the failure mode are recorded. Partial composite behaviour is observed in all specimens when the cracking load is achieved. Finite element analysis is also carried out to study the effect of slenderness ratio and shear connectors which are the major parameters that affect the strength and behaviour of the panels. An empirical equation to predict the maximum load carrying capacity of the panels is proposed. The PLFP system proposed in this research is able to achieve the intended strength for use in low rise building. Considering its lightweight and precast construction method, it is feasible to be developed further as a competitive IBS building system

    Switching Frequency Effects on the Efficiency and Harmonic Distortion in a Three-Phase Five-Level CHBMI Prototype with Multicarrier PWM Schemes: Experimental Analysis

    Get PDF
    The current climatic scenario requires the use of innovative solutions to increase the production of electricity from renewable energy sources. Multilevel Power Inverters are a promising solution to improve the penetration of renewable energy sources into the electrical grid. Moreover, the performance of MPIs is a function of the modulation strategy employed and of its features (modulation index and switching frequency). This paper presents an extended and experimental analysis of three-phase five-level Cascaded H-Bridges Multilevel Inverter performance in terms of efficiency and harmonic content considering several MC PWM modulation strategies. In detail, the CHBMI performance is analyzed by varying the modulation index and the switching frequency. For control purposes, the NI System On Module sbRIO-9651 control board, a dedicated FPGA-based control board for power electronics and drive applications programmable in the LabVIEW environment, is used. The paper describes the modulation strategies implementation, the test bench set-up, and the experimental investigations carried out. The results obtained in terms of Total Harmonic Distorsion (THD) and efficiency are analyzed, compared, and discussed

    Grid integration of renewable power generation

    Get PDF
    This thesis considers the use of three-phase voltage and current source inverters as interfacing units for renewable power, specifically photovoltaic (PV) into the ac grid. This thesis presented two modulation strategies that offer the possibility of operating PV inverters in grid and islanding modes, with reduced switching losses. The first modulation strategy is for the voltage source inverter (VSI), and exploits 3rd harmonic injection with selective harmonic elimination (SHE) to improve performance at low and high modulation indices, where the traditional SHE implementation experiences difficulties due to pulse dropping. The simulations and experimentation presented show that the proposed SHE allows grid PV inverters to be operated with less than a 1kHz effective switching frequency per device. This is vital in power generation, especially in medium and high power applications. Pulse dropping is avoided as the proposed modified SHE spreads the switching angles over 90°, in addition increasing the modulation index. The second proposed modulation strategy, called direct regular sampled pulse width modulation (DRSPWM), is for the current source inverter (CSI). It exploits a combination of forced and natural commutation imposed by the co-existence of an insulated gate bipolar transistor in series with a diode in a three phase current source inverter, to determine device dwell times and switching sequence selection. The DRSPWM strategy reduces switching frequency per device in a CSI by suspending each phase for 60°, similar to VSI dead-band, thus low switching losses are expected. Other benefits include simple digital platform implementation and more flexible switching sequence selection and pulse placement than with space vector modulation. The validity of the DRSPWM is confirmed using simulations and experimentation. This thesis also presents a new dc current offset compensation technique used to facilitate islanding or grid operation of inverter based distributed generation, with a reduced number of interfacing transformers. The proposed technique will enable transformerless operation of all inverters within the solar farm, and uses only one power transformer at the point of common coupling. The validity of the presented modulation strategies and dc current offset compensation technique are substantiated using simulations and experimentation.This thesis considers the use of three-phase voltage and current source inverters as interfacing units for renewable power, specifically photovoltaic (PV) into the ac grid. This thesis presented two modulation strategies that offer the possibility of operating PV inverters in grid and islanding modes, with reduced switching losses. The first modulation strategy is for the voltage source inverter (VSI), and exploits 3rd harmonic injection with selective harmonic elimination (SHE) to improve performance at low and high modulation indices, where the traditional SHE implementation experiences difficulties due to pulse dropping. The simulations and experimentation presented show that the proposed SHE allows grid PV inverters to be operated with less than a 1kHz effective switching frequency per device. This is vital in power generation, especially in medium and high power applications. Pulse dropping is avoided as the proposed modified SHE spreads the switching angles over 90°, in addition increasing the modulation index. The second proposed modulation strategy, called direct regular sampled pulse width modulation (DRSPWM), is for the current source inverter (CSI). It exploits a combination of forced and natural commutation imposed by the co-existence of an insulated gate bipolar transistor in series with a diode in a three phase current source inverter, to determine device dwell times and switching sequence selection. The DRSPWM strategy reduces switching frequency per device in a CSI by suspending each phase for 60°, similar to VSI dead-band, thus low switching losses are expected. Other benefits include simple digital platform implementation and more flexible switching sequence selection and pulse placement than with space vector modulation. The validity of the DRSPWM is confirmed using simulations and experimentation. This thesis also presents a new dc current offset compensation technique used to facilitate islanding or grid operation of inverter based distributed generation, with a reduced number of interfacing transformers. The proposed technique will enable transformerless operation of all inverters within the solar farm, and uses only one power transformer at the point of common coupling. The validity of the presented modulation strategies and dc current offset compensation technique are substantiated using simulations and experimentation
    corecore