    New Technology and Techniques for Needle-Based Magnetic Resonance Image-Guided Prostate Focal Therapy

    Get PDF
    The most common diagnosis of prostate cancer is that of localized disease, and unfortunately the optimal type of treatment for these men is not yet certain. Magnetic resonance image (MRI)-guided focal laser ablation (FLA) therapy is a promising potential treatment option for select men with localized prostate cancer, and may result in fewer side effects than whole-gland therapies, while still achieving oncologic control. The objective of this thesis was to develop methods of accurately guiding needles to the prostate within the bore of a clinical MRI scanner for MRI-guided FLA therapy. To achieve this goal, a mechatronic needle guidance system was developed. The system enables precise targeting of prostate tumours through angulated trajectories and insertion of needles with the patient in the bore of a clinical MRI scanner. After confirming sufficient accuracy in phantoms, and good MRI-compatibility, the system was used to guide needles for MRI-guided FLA therapy in eight patients. Results from this case series demonstrated an improvement in needle guidance time and ease of needle delivery compared to conventional approaches. Methods of more reliable treatment planning were sought, leading to the development of a systematic treatment planning method, and Monte Carlo simulations of needle placement uncertainty. The result was an estimate of the maximum size of focal target that can be confidently ablated using the mechatronic needle guidance system, leading to better guidelines for patient eligibility. These results also quantified the benefit that could be gained with improved techniques for needle guidance

    MRI robot for prostate focal laser ablation : An ex vivo study in human prostate

    Get PDF
    Purpose: A novel grid-template-mimicking MR-compatible robot was developed for in-gantry MRI-guided focal laser ablation of prostate cancer. Method: A substantially compact robot was designed and prototyped to meet in-gantry lithotomy ergonomics and allow for accommodation in the perineum. The controller software was reconfigured and integrated with the custom-designed navigation and multi-focal ablation software. Three experiments were conducted: (1) free space accuracy test; (2) phantom study under computed tomography (CT) guidance for image-guided accuracy test and overall workflow; and (3) magnetic resonance imaging (MRI)-guided focal laser ablation of an ex vivo prostate. The free space accuracy study included five targets that were selected across the workspace. The robot was then commanded five times to each target. The phantom study used a gel phantom made with color changing thermos-chromic ink, and four spherical metal fiducials were deployed with the robot. Then, laser ablation was applied, and the phantom was sliced for gross observation. For an MR-guided ex vivo test, a prostate from a donor who died of prostate cancer was obtained and multi-focally ablated using the system within the MRI gantry. The tissue was sliced after ablation for validation. Results: free-space accuracy was 0.38 ± 0.27 mm. The overall system targeting accuracy under CT guidance (including robot, registration, and insertion error) was 2.17 ± 0.47 mm. The planned ablation zone was successfully covered in both acrylamide gel phantom and in human prostate tissue. Conclusions: The new robot can accurately facilitate fiber targeting for MR-guided focal laser ablation of targetable prostate cancer

    Real-time Prostate Motion Tracking For Robot-assisted Laparoscopic Radical Prostatectomy

    Get PDF
    Radical prostatectomy surgery (RP) is the gold standard for treatment of localized prostate cancer (PCa). Recently, emergence of minimally invasive techniques such as Laparoscopic Radical Prostatectomy (LRP) and Robot-Assisted Laparoscopic Radical Prostatectomy (RARP) has improved the outcomes for prostatectomy. However, it remains difficult for surgeons to make informed decisions regarding resection margins and nerve sparing since the location of the tumour within the organ is not usually visible in a laparoscopic view. While MRI enables visualization of the salient structures and cancer foci, its efficacy in LRP is reduced unless it is fused into a stereoscopic view such that homologous structures overlap. Registration of the MRI image and peri-operative ultrasound image either via visual manual alignment or using a fully automated registration can potentially be exploited to bring the pre-operative information into alignment with the patient coordinate system at the beginning of the procedure. While doing so, prostate motion needs to be compensated in real-time to synchronize the stereoscopic view with the pre-operative MRI during the prostatectomy procedure. In this thesis, two tracking methods are proposed to assess prostate rigid rotation and translation for the prostatectomy. The first method presents a 2D-to-3D point-to-line registration algorithm to measure prostate motion and translation with respect to an initial 3D TRUS image. The second method investigates a point-based stereoscopic tracking technique to compensate for rigid prostate motion so that the same motion can be applied to the pre-operative images

    Positive surgical margin during radical prostatectomy: overview of sampling methods for frozen sections and techniques for the secondary resection of the neurovascular bundles

    Get PDF
    Objective: The aim of the paper is to provide an overview of intraoperative sampling methods for frozen section (FS) analysis and of surgical techniques for a secondary neurovascular bundle (NVB) resection, as the method of surgical margin (SM) sampling and the management of a positive SM (PSM) at the nerve-sparing (NS) area are under evaluated issues. FS analysis during radical prostatectomy (RP) can help to tailor the plane of dissection based on cancer extension and thus extend the indications for NS surgery. Evidence Acquisition: We performed a PubMed/Medical Literature Analysis and Retrieval System Online (MEDLINE), Web of Science, Cochrane Library, and Elton B. Stephens Co. (EBSCO)host search to include articles published in the last decade, evaluating FS analysis in the NS area and surgical attempts to convert a PSM to a negative status. Evidence Synthesis: Overall, 19 papers met our inclusion criteria. The ways to collect samples for FS analysis included: systematic (analysing the whole posterolateral aspect of the prostate specimen, i.e., neurovascular structure-adjacent frozen-section examination [NeuroSAFE]); magnetic resonance imaging (MRI)-guided (biopsies from MRI-suspicious areas, retrieved by the surgeon in a cognitive way); and random biopsies from the soft periprostatic tissues. Techniques to address a PSM in the NS area included: full resection of the spared NVB, from its caudal to cranial aspect, often including the rectolateral part of the Denonvilliers’ fascia; partial resection of the NVB, in cases where sampling attempts to localise a PSM; incremental approach, meaning a partial or full resection that extends until no prostate tissue is found in the soft periprostatic environment. Conclusions: There is no homogeneity in prostate sampling for FS analysis, although most recent evidence is moving toward a systematic sampling of the entire NS area. The management of a PSM is variable and can be affected by the sampling strategy (difficult localisation of the persisting tumour at the NVB). The difficult identification of the exact soft tissue location contiguous to a PSM could be considered as the critical point of FS analysis and of spared-NVB management

    Design of an ultrasound-guided robotic brachytherapy needle insertion system

    Full text link
    In this paper we describe a new robotic brachytherapy needle-insertion system that is designed to replace the template used in the manual technique. After a brief review of existing robotic systems, we describe the requirements that we based our design upon. A detailed description of the proposed system follows. Our design is capable of positioning and inclining a needle within the same workspace as the manual template. To help improve accuracy, the needle can be rotated about its axis during insertion into the prostate. The system can be mounted on existing steppers and also easily accommodates existing seed dispensers, such as the Mick Applicator

    Exploiting Temporal Image Information in Minimally Invasive Surgery

    Get PDF
    Minimally invasive procedures rely on medical imaging instead of the surgeons direct vision. While preoperative images can be used for surgical planning and navigation, once the surgeon arrives at the target site real-time intraoperative imaging is needed. However, acquiring and interpreting these images can be challenging and much of the rich temporal information present in these images is not visible. The goal of this thesis is to improve image guidance for minimally invasive surgery in two main areas. First, by showing how high-quality ultrasound video can be obtained by integrating an ultrasound transducer directly into delivery devices for beating heart valve surgery. Secondly, by extracting hidden temporal information through video processing methods to help the surgeon localize important anatomical structures. Prototypes of delivery tools, with integrated ultrasound imaging, were developed for both transcatheter aortic valve implantation and mitral valve repair. These tools provided an on-site view that shows the tool-tissue interactions during valve repair. Additionally, augmented reality environments were used to add more anatomical context that aids in navigation and in interpreting the on-site video. Other procedures can be improved by extracting hidden temporal information from the intraoperative video. In ultrasound guided epidural injections, dural pulsation provides a cue in finding a clear trajectory to the epidural space. By processing the video using extended Kalman filtering, subtle pulsations were automatically detected and visualized in real-time. A statistical framework for analyzing periodicity was developed based on dynamic linear modelling. In addition to detecting dural pulsation in lumbar spine ultrasound, this approach was used to image tissue perfusion in natural video and generate ventilation maps from free-breathing magnetic resonance imaging. A second statistical method, based on spectral analysis of pixel intensity values, allowed blood flow to be detected directly from high-frequency B-mode ultrasound video. Finally, pulsatile cues in endoscopic video were enhanced through Eulerian video magnification to help localize critical vasculature. This approach shows particular promise in identifying the basilar artery in endoscopic third ventriculostomy and the prostatic artery in nerve-sparing prostatectomy. A real-time implementation was developed which processed full-resolution stereoscopic video on the da Vinci Surgical System

    Image-guided prostate biopsy robots: A review

    Get PDF
    At present, the incidence of prostate cancer (PCa) in men is increasing year by year. So, the early diagnosis of PCa is of great significance. Transrectal ultrasonography (TRUS)-guided biopsy is a common method for diagnosing PCa. The biopsy process is performed manually by urologists but the diagnostic rate is only 20%–30% and its reliability and accuracy can no longer meet clinical needs. The image-guided prostate biopsy robot has the advantages of a high degree of automation, does not rely on the skills and experience of operators, reduces the work intensity and operation time of urologists and so on. Capable of delivering biopsy needles to pre-defined biopsy locations with minimal needle placement errors, it makes up for the shortcomings of traditional free-hand biopsy and improves the reliability and accuracy of biopsy. The integration of medical imaging technology and the robotic system is an important means for accurate tumor location, biopsy puncture path planning and visualization. This paper mainly reviews image-guided prostate biopsy robots. According to the existing literature, guidance modalities are divided into magnetic resonance imaging (MRI), ultrasound (US) and fusion image. First, the robot structure research by different guided methods is the main line and the actuators and material research of these guided modalities is the auxiliary line to introduce and compare. Second, the robot image-guided localization technology is discussed. Finally, the image-guided prostate biopsy robot is summarized and suggestions for future development are provided

    Clinically significant prostate cancer diagnosed using a urinary molecular biomarker-based risk score : two case reports

    Get PDF
    Background: Identifying men for a repeat prostate biopsy is a conundrum to urologists. Risk calculators (RCs) such as the European Randomized Study of Screening for Prostate Cancer (ERSPC) RCs have been developed to predict the outcome of prostate biopsies and have been shown to improve diagnostic accuracy compared to PSA alone. However, it was recently shown that the outcome for high-grade prostate cancer (PCa) upon biopsy tended to be underestimated in men with previous negative biopsies using ERSPC RC model 4. For these men, an individualized approach combining the clinical information with the outcome of biomarker-related urine tests may help to make a more informed decision. Case presentation Two men, aged 66 and 69 respectively when presented in the clinic, show the typical dilemma of urologist and patient for electing repeat prostate biopsy. Both men had normal DRE findings, did not have a family history of PCa, presented with serum PSA values between 3 and 10 ng/ml and the first biopsies were negative for disease. The ERSPC RC4 did not indicate a biopsy in these men. The urinary molecular biomarker-based test for HOXC6 and DLX1, combining biomarker-expression profiling with clinical risk factors, resulted in SelectMDx Risk scores for these men that were higher than the cut-off of the test. Based on this outcome, mpMRI was performed with an outcome of PI-RADS >= 4 in both men. Histopathological evaluation of TRUS-guided biopsies confirmed high-grade PCa. Conclusions: The urinary molecular biomarker-based risk score played a pivotal role in the diagnosis of clinically significant PCa whereas ERSPC RC4 outcome would not have indicated further diagnostic follow-up in these two cases. The timely diagnosis was shown to be crucial for the curative treatment by radical retropubic prostatectomy and the potential life-years gained for these two vital males

    Image-Fusion for Biopsy, Intervention, and Surgical Navigation in Urology