2,935 research outputs found

    Three-dimensional scanning of specular and diffuse metallic surfaces using an infrared technique

    Get PDF
    For the past two decades, the need for three-dimensional (3-D) scanning of industrial objects has increased significantly and many experimental techniques and commercial solutions have been proposed. However, difficulties remain for the acquisition of optically non-cooperative surfaces, such as transparent or specular surfaces. To address highly reflective metallic surfaces, we propose the extension of a technique that was originally dedicated to glass objects. In contrast to conventional active triangulation techniques that measure the reflection of visible radiation, we measure the thermal emission of a surface, which is locally heated by a laser source. Considering the thermophysical properties of metals, we present a simulation model of heat exchanges that are induced by the process, helping to demonstrate its feasibility on specular metallic surfaces and predicting the settings of the system. With our experimental device, we have validated the theoretical modeling and computed some 3-D point clouds from specular surfaces of various geometries. Furthermore, a comparison of our results with those of a conventional system on specular and diffuse parts will highlight that the accuracy of the measurement no longer depends on the roughness of the surface

    Quantum differential ghost microscopy

    Full text link
    Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol able to compensate for the detrimental effect of detection noise and losses. This represents an important improvement as quantum correlations allow low brightness imaging, desirable for reducing the absorption dose. In particular, we develop a comprehensive model starting from a ghost imaging scheme elaborated for bright thermal light, known as differential ghost imaging and particularly suitable in the relevant case of faint or sparse objects. We perform the experiment using SPDC light in microscopic configuration. The image is reconstructed exploiting non-classical intensity correlation rather than photon pairs detection coincidences. On one side we validate the theoretical model and on the other we show the applicability of this technique by reconstructing a biological object with 5 micrometers resolution

    3D Scanning, Imaging, and Printing in Orthodontics

    Get PDF

    LIME : Software for 3-D visualization, interpretation, and communication of virtual geoscience models

    Get PDF
    Parts of LIME have been developed to address research requirements in projects funded by the Research Council of Norway (RCN) through the Petromaks and Petromaks 2 programs. The following grants are acknowledged: 153264 (VOG [Virtual Outcrop Geology]; with Statoil ASA), 163316 (Carbonate Reservoir Geomodels [IRIS (International Research Institute of Stavanger)]), 176132 (Paleokarst Reservoirs [Uni Research CIPR]), 193059 (EUSA; with FORCE Sedimentology and Stratigraphy Group), 234152 (Trias North [University of Oslo]; with Deutsche Erdoel AG, Edison, Lundin, Statoil, and Tullow), 234111 (VOM2MPS [Uni Research CIPR]; with FORCE Sedimentology and Stratigraphy Group), as well as SkatteFUNN (RCN) project 266740. In addition, the SAFARI project consortium (http://safaridb.com) is thanked for its continued support. The OSG and wxWidgets communities are acknowledged for ongoing commitment to providing mature and powerful software libraries. All authors thank colleagues past and present for studies culminating in the presented figures: Kristine Smaadal and Aleksandra Sima (Figs. 1 and 4); Colm Pierce (Fig. 2A); Eivind Bastesen, Roy Gabrielsen and Haakon Fossen (Fig. 3); Christian Haug Eide (Fig. 7); Ivar Grunnaleite and Gunnar Sælen (Fig. 8); and Magda Chmielewska (Fig. 9). Isabelle Lecomte contributed to discussions on geospatial-geophysical data fusion. Bowei Tong and Joris Vanbiervliet are acknowledged for internal discussions during article revision. The lead author thanks Uni Research for providing a base funding grant to refine some of the presented features. Finally, authors Buckley and Dewez are grateful to Institut Carnot BRGM for the RADIOGEOM mobility grant supporting the writing of this paper. Corbin Kling and one anonymous reviewer helped improve the final manuscript.Peer reviewedPublisher PD

    Guidance for benthic habitat mapping: an aerial photographic approach

    Get PDF
    This document, Guidance for Benthic Habitat Mapping: An Aerial Photographic Approach, describes proven technology that can be applied in an operational manner by state-level scientists and resource managers. This information is based on the experience gained by NOAA Coastal Services Center staff and state-level cooperators in the production of a series of benthic habitat data sets in Delaware, Florida, Maine, Massachusetts, New York, Rhode Island, the Virgin Islands, and Washington, as well as during Center-sponsored workshops on coral remote sensing and seagrass and aquatic habitat assessment. (PDF contains 39 pages) The original benthic habitat document, NOAA Coastal Change Analysis Program (C-CAP): Guidance for Regional Implementation (Dobson et al.), was published by the Department of Commerce in 1995. That document summarized procedures that were to be used by scientists throughout the United States to develop consistent and reliable coastal land cover and benthic habitat information. Advances in technology and new methodologies for generating these data created the need for this updated report, which builds upon the foundation of its predecessor

    Comparing the trueness of seven intraoral scanners and a physical impression on dentate human maxilla by a novel method

    Get PDF
    Intraoral scanner (IOS) accuracy is commonly evaluated using full-arch surface comparison, which fails to take into consideration the starting position of the scanning (scan origin). Previously a novel method was developed, which takes into account the scan origin and calculates the deviation of predefined identical points between references and test models. This method may reveal the error caused by stitching individual images during intraoral scan. This study aimed to validate the novel method by comparing the trueness of seven IOSs (Element 1, Element 2, Emerald, Omnicam, Planscan, Trios 3, CS 3600) to a physical impression digitized by laboratory scanner which lacks linear stitching problems

    Three-Dimensional Shape Measurements of Specular Objects Using Phase-Measuring Deflectometry

    Get PDF
    The fast development in the fields of integrated circuits, photovoltaics, the automobile industry, advanced manufacturing, and astronomy have led to the importance and necessity of quickly and accurately obtaining three-dimensional (3D) shape data of specular surfaces for quality control and function evaluation. Owing to the advantages of a large dynamic range, non-contact operation, full-field and fast acquisition, high accuracy, and automatic data processing, phase-measuring deflectometry (PMD, also called fringe reflection profilometry) has been widely studied and applied in many fields. Phase information coded in the reflected fringe patterns relates to the local slope and height of the measured specular objects. The 3D shape is obtained by integrating the local gradient data or directly calculating the depth data from the phase information. We present a review of the relevant techniques regarding classical PMD. The improved PMD technique is then used to measure specular objects having discontinuous and/or isolated surfaces. Some influential factors on the measured results are presented. The challenges and future research directions are discussed to further advance PMD techniques. Finally, the application fields of PMD are briefly introduce
    corecore