576 research outputs found

    Motion from Fixation

    Get PDF
    We study the problem of estimating rigid motion from a sequence of monocular perspective images obtained by navigating around an object while fixating a particular feature point. The motivation comes from the mechanics of the buman eye, which either pursuits smoothly some fixation point in the scene, or "saccades" between different fixation points. In particular, we are interested in understanding whether fixation helps the process of estimating motion in the sense that it makes it more robust, better conditioned or simpler to solve. We cast the problem in the framework of "dynamic epipolar geometry", and propose an implicit dynamical model for recursively estimating motion from fixation. This allows us to compare directly the quality of the estimates of motion obtained by imposing the fixation constraint, or by assuming a general rigid motion, simply by changing the geometry of the parameter space while maintaining the same structure of the recursive estimator. We also present a closed-form static solution from two views, and a recursive estimator of the absolute attitude between the viewer and the scene. One important issue is how do the estimates degrade in presence of disturbances in the tracking procedure. We describe a simple fixation control that converges exponentially, which is complemented by a image shift-registration for achieving sub-pixel accuracy, and assess how small deviations from perfect tracking affect the estimates of motion

    Omnidirectional Vision Based Topological Navigation

    Get PDF
    Goedemé T., Van Gool L., ''Omnidirectional vision based topological navigation'', Mobile robots navigation, pp. 172-196, Barrera Alejandra, ed., March 2010, InTech.status: publishe

    Purposive three-dimensional reconstruction by means of a controlled environment

    Get PDF
    Retrieving 3D data using imaging devices is a relevant task for many applications in medical imaging, surveillance, industrial quality control, and others. As soon as we gain procedural control over parameters of the imaging device, we encounter the necessity of well-defined reconstruction goals and we need methods to achieve them. Hence, we enter next-best-view planning. In this work, we present a formalization of the abstract view planning problem and deal with different planning aspects, whereat we focus on using an intensity camera without active illumination. As one aspect of view planning, employing a controlled environment also provides the planning and reconstruction methods with additional information. We incorporate the additional knowledge of camera parameters into the Kanade-Lucas-Tomasi method used for feature tracking. The resulting Guided KLT tracking method benefits from a constrained optimization space and yields improved accuracy while regarding the uncertainty of the additional input. Serving other planning tasks dealing with known objects, we propose a method for coarse registration of 3D surface triangulations. By the means of exact surface moments of surface triangulations we establish invariant surface descriptors based on moment invariants. These descriptors allow to tackle tasks of surface registration, classification, retrieval, and clustering, which are also relevant to view planning. In the main part of this work, we present a modular, online approach to view planning for 3D reconstruction. Based on the outcome of the Guided KLT tracking, we design a planning module for accuracy optimization with respect to an extended E-criterion. Further planning modules endow non-discrete surface estimation and visibility analysis. The modular nature of the proposed planning system allows to address a wide range of specific instances of view planning. The theoretical findings in this work are underlined by experiments evaluating the relevant terms

    Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment

    Get PDF
    Includes abstract.Includes bibliographical references.Clinicians often take measurements between anatomical landmarks on X-ray radiographs for diagnosis and treatment planning, for example in orthopaedics and orthodontics. X-ray images, however, overlap three-dimensional internal structures onto a two-dimensional plane during image formation. Depth information is therefore lost and measurements do not truly reflect spatial relationships. The main aim of this study was to develop an inter-landmark measurement tool for the Lodox Statscan digital radiography system. X-ray stereophotogrammetry was applied to Statscan images to enable three-dimensional point localization for inter-landmark measurement using two-dimensional radiographs. This technique requires images of the anatomical region of interest to be acquired from different perspectives as well as a suitable calibration tool to map image coordinates to real world coordinates. The Statscan is suited to the technique because it is capable of axial rotations for multiview imaging. Three-dimensional coordinate reconstruction and inter-landmark measurements were taken using a planar object and a dry pelvis specimen in order to assess the intra-observer measurement accuracy, reliability and precision. The system yielded average (X, Y, Z) coordinate reconstruction accuracy of (0.08 0.12 0.34) mm and resultant coordinate reconstruction accuracy within 0.4mm (range 0.3mm – 0.6mm). Inter-landmark measurements within 2mm for lengths and 1.80 for angles were obtained, with average accuracies of 0.4mm (range 0.0mm – 2.0 mm) and 0.30 (range 0.0 – 1.8)0 respectively. The results also showed excellent overall precision of (0.5mm, 0.10) and were highly reliable when all landmarks were completely visible in both images. Femoral neck anteversion measurement on Statscan images was also explored using 30 dry right adult femurs. This was done in order to assess the feasibility of the algorithm for a clinical application. For this investigation, four methods were tested to determine the optimal landmarks for measurement and the measurement process involved calculation of virtual landmarks. The method that yielded the best results produced all measurements within 10 of reference values and the measurements were highly reliable with very good precision within 0.10. The average accuracy was within 0.40 (range 0.10 –0.80).In conclusion, X-ray stereophotogrammetry enables accurate, reliable and precise inter-landmark measurements for the Lodox Statscan X-ray imaging system. The machine may therefore be used as an inter-landmark measurement tool for routine clinical applications

    Real-time synthetic primate vision

    Get PDF

    Multi Camera Stereo and Tracking Patient Motion for SPECT Scanning Systems

    Get PDF
    Patient motion, which causes artifacts in reconstructed images, can be a serious problem in Single Photon Emission Computed Tomography (SPECT) imaging. If patient motion can be detected and quantified, the reconstruction algorithm can compensate for the motion. A real-time multi-threaded Visual Tracking System (VTS) using optical cameras, which will be suitable for deployment in clinical trials, is under development. The VTS tracks patients using multiple video images and image processing techniques, calculating patient motion in three-dimensional space. This research aimed to develop and implement an algorithm for feature matching and stereo location computation using multiple cameras. Feature matching is done based on the epipolar geometry constraints for a pair of images and extended to the multiple view case with an iterative algorithm. Stereo locations of the matches are then computed using sum of squared distances from the projected 3D lines in SPECT coordinates as the error metric. This information from the VTS, when coupled with motion assessment from the emission data itself, can provide a robust compensation for patient motion as part of reconstruction
    corecore