110 research outputs found

    Artificial intelligence for ultrasound scanning in regional anaesthesia: a scoping review of the evidence from multiple disciplines

    Get PDF
    Background Artificial intelligence (AI) for ultrasound scanning in regional anaesthesia is a rapidly developing interdisciplinary field. There is a risk that work could be undertaken in parallel by different elements of the community but with a lack of knowledge transfer between disciplines, leading to repetition and diverging methodologies. This scoping review aimed to identify and map the available literature on the accuracy and utility of AI systems for ultrasound scanning in regional anaesthesia. Methods A literature search was conducted using Medline, Embase, CINAHL, IEEE Xplore, and ACM Digital Library. Clinical trial registries, a registry of doctoral theses, regulatory authority databases, and websites of learned societies in the field were searched. Online commercial sources were also reviewed. Results In total, 13,014 sources were identified; 116 were included for full-text review. A marked change in AI techniques was noted in 2016–17, from which point on the predominant technique used was deep learning. Methods of evaluating accuracy are variable, meaning it is impossible to compare the performance of one model with another. Evaluations of utility are more comparable, but predominantly gained from the simulation setting with limited clinical data on efficacy or safety. Study methodology and reporting lack standardisation. Conclusions There is a lack of structure to the evaluation of accuracy and utility of AI for ultrasound scanning in regional anaesthesia, which hinders rigorous appraisal and clinical uptake. A framework for consistent evaluation is needed to inform model evaluation, allow comparison between approaches/models, and facilitate appropriate clinical adoption

    Advancements and Breakthroughs in Ultrasound Imaging

    Get PDF
    Ultrasonic imaging is a powerful diagnostic tool available to medical practitioners, engineers and researchers today. Due to the relative safety, and the non-invasive nature, ultrasonic imaging has become one of the most rapidly advancing technologies. These rapid advances are directly related to the parallel advancements in electronics, computing, and transducer technology together with sophisticated signal processing techniques. This book focuses on state of the art developments in ultrasonic imaging applications and underlying technologies presented by leading practitioners and researchers from many parts of the world

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Mixed-reality visualization environments to facilitate ultrasound-guided vascular access

    Get PDF
    Ultrasound-guided needle insertions at the site of the internal jugular vein (IJV) are routinely performed to access the central venous system. Ultrasound-guided insertions maintain high rates of carotid artery puncture, as clinicians rely on 2D information to perform a 3D procedure. The limitations of 2D ultrasound-guidance motivated the research question: “Do 3D ultrasound-based environments improve IJV needle insertion accuracy”. We addressed this by developing advanced surgical navigation systems based on tracked surgical tools and ultrasound with various visualizations. The point-to-line ultrasound calibration enables the use of tracked ultrasound. We automated the fiducial localization required for this calibration method such that fiducials can be automatically localized within 0.25 mm of the manual equivalent. The point-to-line calibration obtained with both manual and automatic localizations produced average normalized distance errors less than 1.5 mm from point targets. Another calibration method was developed that registers an optical tracking system and the VIVE Pro head-mounted display (HMD) tracking system with sub-millimetre and sub-degree accuracy compared to ground truth values. This co-calibration enabled the development of an HMD needle navigation system, in which the calibrated ultrasound image and tracked models of the needle, needle trajectory, and probe were visualized in the HMD. In a phantom experiment, 31 clinicians had a 96 % success rate using the HMD system compared to 70 % for the ultrasound-only approach (p= 0.018). We developed a machine-learning-based vascular reconstruction pipeline that automatically returns accurate 3D reconstructions of the carotid artery and IJV given sequential tracked ultrasound images. This reconstruction pipeline was used to develop a surgical navigation system, where tracked models of the needle, needle trajectory, and the 3D z-buffered vasculature from a phantom were visualized in a common coordinate system on a screen. This system improved the insertion accuracy and resulted in 100 % success rates compared to 70 % under ultrasound-guidance (p=0.041) across 20 clinicians during the phantom experiment. Overall, accurate calibrations and machine learning algorithms enable the development of advanced 3D ultrasound systems for needle navigation, both in an immersive first-person perspective and on a screen, illustrating that 3D US environments outperformed 2D ultrasound-guidance used clinically

    The radiological investigation of musculoskeletal tumours : chairperson's introduction

    No full text

    Infective/inflammatory disorders

    Get PDF

    PRELIMINARY FINDINGS OF A POTENZIATED PIEZOSURGERGICAL DEVICE AT THE RABBIT SKULL

    Get PDF
    The number of available ultrasonic osteotomes has remarkably increased. In vitro and in vivo studies have revealed differences between conventional osteotomes, such as rotating or sawing devices, and ultrasound-supported osteotomes (Piezosurgery®) regarding the micromorphology and roughness values of osteotomized bone surfaces. Objective: the present study compares the micro-morphologies and roughness values of osteotomized bone surfaces after the application of rotating and sawing devices, Piezosurgery Medical® and Piezosurgery Medical New Generation Powerful Handpiece. Methods: Fresh, standard-sized bony samples were taken from a rabbit skull using the following osteotomes: rotating and sawing devices, Piezosurgery Medical® and a Piezosurgery Medical New Generation Powerful Handpiece. The required duration of time for each osteotomy was recorded. Micromorphologies and roughness values to characterize the bone surfaces following the different osteotomy methods were described. The prepared surfaces were examined via light microscopy, environmental surface electron microscopy (ESEM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM) and atomic force microscopy. The selective cutting of mineralized tissues while preserving adjacent soft tissue (dura mater and nervous tissue) was studied. Bone necrosis of the osteotomy sites and the vitality of the osteocytes near the sectional plane were investigated, as well as the proportion of apoptosis or cell degeneration. Results and Conclusions: The potential positive effects on bone healing and reossification associated with different devices were evaluated and the comparative analysis among the different devices used was performed, in order to determine the best osteotomes to be employed during cranio-facial surgery

    Methods for Arrhythmogenic Substrate Identification and Procedural Improvements for Ventricular Arrhythmias.

    Get PDF
    Ventricular arrhythmias (VA) are a frequent precursor to sudden cardiac death (SCD) in patients with structural heart disease (SHD). Patients with SHD are at risk of recurrent ventricular tachycardia (VT), which generally occurs due to re-entry within and around the presence of an arrhythmogenic scar. Therefore, scarred myocardium forms the necessary substrate for arrhythmogenesis to occur. A scar may occur due to obstructive coronary artery disease, causing ischaemic cardiomyopathy (ICM), or from cardiac injury due to several other causes, including inflammatory, infiltrative, toxin-mediated, or genetic heart disease, termed non-ischaemic cardiomyopathy (NICM). An implantable cardioverting defibrillator (ICD) can abort SCD from recurrent VAs. However, they do not stop VAs from occurring in the first place. Anti-arrhythmic drugs (AADs) may reduce the frequency and burden of VAs but have limited efficacy. Some have a narrow therapeutic window or the potential for multiorgan toxicity and can be poorly tolerated. Catheter ablation (CA) is a class I indication for treating sustained monomorphic VT refractory to AADs. CA reduces VT burden, the number of defibrillator therapies, greater freedom from recurrent ventricular arrhythmia, and improves quality of life. However, recurrences can be experienced in up to 50% of patients with SHD-related VT. Some reasons for the failure of CA include reliable identification of critical components of substrate that can harbour VAs both in sinus rhythm and during ongoing VT using electroanatomic mapping (EAM) and imaging techniques, as well as limitations in assessing intraprocedural endpoints. Further refinement of electroanatomic mapping techniques is required to improve the efficacy of CA. This thesis aims to expand on current techniques for substrate identification and methods to improve the efficacy of VA ablation procedures

    CT Scanning

    Get PDF
    Since its introduction in 1972, X-ray computed tomography (CT) has evolved into an essential diagnostic imaging tool for a continually increasing variety of clinical applications. The goal of this book was not simply to summarize currently available CT imaging techniques but also to provide clinical perspectives, advances in hybrid technologies, new applications other than medicine and an outlook on future developments. Major experts in this growing field contributed to this book, which is geared to radiologists, orthopedic surgeons, engineers, and clinical and basic researchers. We believe that CT scanning is an effective and essential tools in treatment planning, basic understanding of physiology, and and tackling the ever-increasing challenge of diagnosis in our society
    • …
    corecore