282 research outputs found

    Vicarious Methodologies to Assess and Improve the Quality of the Optical Remote Sensing Images: A Critical Review

    Get PDF
    Over the past decade, number of optical Earth observing satellites performing remote sensing has increased substantially, dramatically increasing the capability to monitor the Earth. The quantity of remote sensing satellite increase is primarily driven by improved technology, miniaturization of components, reduced manufacturing, and launch cost. These satellites often lack on-board calibrators that a large satellite utilizes to ensure high quality (e.g., radiometric, geometric, spatial quality, etc.) scientific measurement. To address this issue, this work presents “best” vicarious image quality assessment and improvement techniques for those kinds of optical satellites which lacks on-board calibration system. In this article, image quality categories have been explored, and essential quality parameters (e.g., absolute and relative calibration, aliasing, etc.) have been identified. For each of the parameters, appropriate characterization methods are identified along with its specifications or requirements. In cases of multiple methods, recommendation has been made based-on the strengths and weaknesses of each method. Furthermore, processing steps have been presented, including examples. Essentially, this paper provides a comprehensive study of the criteria that needs to be assessed to evaluate remote sensing satellite data quality, and best vicarious methodologies to evaluate identified quality parameters such as coherent noise, ground sample distance, etc

    Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

    Get PDF
    Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS

    Forty-Year Calibrated Record of Earth-Surface Reflected Radiance from Landsat: A Review

    Get PDF
    Sensors on Landsat satellites have been collecting images of the Earth's surface for nearly 40 years. These images have been invaluable for characterizing and detecting changes in the land cover and land use of the world. Although initially conceived as primarily picture generating sensors, even the early sensors were radiometrically calibrated and spectrally characterized prior to launch and incorporated some capabilities to monitor their radiometric calibration once on orbit. Recently, as the focus of studies has shifted to monitoring Earth surface parameters over significant periods of time, serious attention has been focused toward bringing the data from all these sensors onto a common radiometric scale over this 40-year period. This effort started with the most recent systems and then was extended back in time. Landsat-7 ETM+, the best-characterized sensor of the series prior to launch and once on orbit, and the most stable system to date, was chosen to serve as the reference. The Landsat-7 project was the first of the series to build an image assessment system into its ground system, allowing systematic characterization of its sensors and data. Second, the Landsat-5 TM (still operating at the time of the Landsat-7 launch and continues to operate) calibration history was reconstructed based on its internal calibrator, vicarious calibrations, pseudo-invariant sites and a tie to Landsat-7 ETM+ at the time of the commissioning of Landsat-7. This process was performed in two iterations: the earlier one relied primarily on the TM internal calibrator. When this was found to have some deficiencies, a revised calibration was based more on pseudo-invariant sites, though the internal calibrator was still used to establish the short-term variations in response due to icing build up on the cold focal plane. As time progressed, a capability to monitor the Landsat-5 TM was added to the image assessment system. The Landsat-4 TM, which operated from 1982-1992, was the third system to which the radiometric scale was extended. The limited and broken use of the Landsat-4 TM made this analysis more difficult. Eight-day separated image pairs from Landsat-5 combined with analysis of pseudo invariant sites established this history. The fourth and most challenging effort was making the Landsat-1 to -5 MSS sensors' data internally radiometrically consistent. This effort was particularly complicated by the age of the MSS data, varying formats and processing levels in the archive, limited datasets, and limited documentation available. Ultimately, pseudo-invariant sites were identified in North America and used for this effort. Note that most of the Landsat-MSS archived data had already been calibrated using the MSS internal calibrators, so this processing was imbedded in the result. The final effort was developing an absolute scale for Landsat MSS similar to what was already established for the "TM" sensors. This was accomplished by using simultaneous data from Landsat-5 MSS and Landsat-5 TM, accounting for spectral differences between the sensors using EO-1 Hyperion data. The recalibrated history of the Landsat data and implications to users are discussed. The key result from this work is a consistently calibrated Landsat data archive that spans nearly 40 years with total uncertainties on the order of 10% or less for most sensors and bands

    Hyperspectral Empirical Absolute Calibration Model Using Libya 4 Pseudo-Invariant Calibration Site

    Get PDF
    The objective of this paper is to find an empirical hyperspectral absolute calibration model using Libya 4 pseudo-invariant calibration site (PICS). The approach involves using the Landsat 8 (L8) Operational Land Imager (OLI) as the reference radiometer and using Earth Observing One (EO-1) Hyperion, with a spectral resolution of 10 nm as a hyperspectral source. This model utilizes data from a region of interest (ROI) in an “optimal region” of 3% temporal, spatial, and spectral stability within the Libya 4 PICS. It uses an improved, simple, empirical, hyperspectral Bidirectional Reflectance Distribution function (BRDF) model accounting for four angles: solar zenith and azimuth, and view zenith and azimuth angles. This model can perform absolute calibration in 1 nm spectral resolution by predicting TOA reflectance in all existing spectral bands of the sensors. The resultant model was validated with image data acquired from satellite sensors such as Landsat 7, Sentinel 2A, and Sentinel 2B, Terra MODIS, Aqua MODIS, from their launch date to 2020. These satellite sensors differ in terms of the width of their spectral band-pass, overpass time, off-nadir viewing capabilities, spatial resolution, and temporal revisit time, etc. The result demonstrates the efficacy of the proposed model has an accuracy of the order of 3% with a precision of about 3% for the nadir viewing sensors (with view zenith angle up to 5°) used in the study. For the off-nadir viewing satellites with view zenith angle up to 20°, it can have an estimated accuracy of 6% and precision of 4%

    Design Analysis of a Sapce Based Chromotomographic Hyperspectral Imaging Experiment

    Get PDF
    This research develops the design of several components and/or systems for an experimental space-based chromotomographic hyperspectral imager that is being built by the Air Force Institute of Technology. The design work includes three separate topics. The first topic was the development of a structure utilizing finite element analysis and eigenanalysis for the ground-based version of the chromotomographic experiment (CTEx). The ground-based experiment was performed as a risk mitigation measure for the space-based experiment. The second topic includes a design review of a contractor\u27s proposed off-axis Mersenne telescope for the space-based chromotomographic hyperspectral imager. The work included the creation of preliminary verification requirements from the contract and sub- sequent analysis of the telescope design based on those requirements. The third topic addressed was a trade study of on-orbit focus, alignment, and calibration schemes for the space-based version of CTEx. The selected imaging focusing method entails imaging Earth-based sodium lights at night while stepping through several focus settings. The optimal focus setting shows the clearest sodium spectral features. The critical alignment concerns were identified as the alignment of the prism and of the collimated light onto the prism. The space-based CTEx utilizes three separate calibration methods involving vicarious Earth-based targets, and on-board laser diodes and spectral filters. The results of the research varied by topic. For the first topic, a structural assembly was successfully fabricated that allowed the goals of the ground-based CTEx to be met, validating the design approach. The design review for the second topic was successful with the contractor\u27s telescope design currently undergoing fabrication with delivery in May 2010. For the third topic, applicable methods and procedures were developed for the space-based CTEx

    PACE Technical Report Series, Volume 5: Mission Formulation Studies

    Get PDF
    This chapter summarizes the mission architecture for the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, ranging from its scientific rationale to the history of its realized conception to itspresent-day organization and management. This volume in the PACE Technical Report series focuses ontrade studies that informed the formulation of the mission in its pre-Phase A (2014-2016; pre-formulation:define a viable and affordable concept) and Phase A (2016-2017; concept and technology development).With that in mind, this chapter serves to introduce the mission by providing: a brief summary of thescience drivers for the mission; a history of the direction of the mission to NASA's Goddard Space Flight Center (GSFC); a synopsis of the mission's and instruments' management and development structures; and a brief description of the primary components and elements that form the foundation ofthe mission, encompassing the major mission segments (space, ground, and science data processing) and their roles in integration, testing, and operations

    An Integrated physics-based approach to demonstrate the potential of the Landsat Data Continuity Mission (LDCM) for monitoring coastal/inland waters

    Get PDF
    Monitoring coastal or inland waters, recognized as case II waters, using the existing Landsat technology is somewhat restricted because of its low Signal-to-Noise ratio (SNR) as well as its relatively poor radiometric resolution. As a primary task, we introduce a novel technique, which integrates the Landsat-7 data as a surrogate for LDCM with a 3D hydrodynamic model to monitor the dynamics of coastal waters near river discharges as well as in a small lake environment. The proposed approach leverages both the thermal and the reflective Landsat-7 imagery to calibrate the model and to retrieve the concentrations of optically active components of the water. To do so, the model is first calibrated by optimizing its thermal outputs with the surface temperature maps derived from the Landsat-7 data. The constituent retrieval is conducted in the second phase where multiple simulated concentration maps are provided to an in-water radiative transfer code (Hydrolight) to generate modeled surface reflectance maps. Prior to any remote sensing task, one has to ensure that a dataset comes from a well-calibrated imaging system. Although the calibration status of Landsat-7 has been regularly monitored over multiple desert sites, it was desired to evaluate its performance over dark waters relative to a well-calibrated instrument designed specifically for water studies. In the light of this, several Landsat- 7 images were cross-calibrated against the Terra-MODIS data over deep, dark waters whose optical properties remain relatively stable. This study is intended to lay the groundwork and provide a reference point for similar studies planned for the new Landsat. In an independent case study, the potential of the new Landsat sensor was examined using an EO-1 dataset and applying a spectral optimization approach over case II waters. The water constituent maps generated from the EO-1 imagery were compared against those derived from Landsat-7 to fully analyze the improvement levels pertaining to the new Landsat\u27s enhanced features in a water constituent retrieval framework

    New Approach for Temporal Stability Evaluation of Pseudo-Invariant Calibration Sites (PICS)

    Get PDF
    Pseudo-Invariant Calibration Sites (PICS) are one of the most popular methods for in-flight vicarious radiometric calibration of Earth remote sensing satellites. The fundamental question of PICS temporal stability has not been adequately addressed. However, the main purpose of this work is to evaluate the temporal stability of a few PICS using a new approach. The analysis was performed over six PICS (Libya 1, Libya 4, Niger 1, Niger 2, Egypt 1 and Sudan 1). The concept of a Virtual Constellation was developed to provide greater temporal coverage and also to overcome the dependence limitation of any specific characteristic derived from one particular sensor. TOA reflectance data from four sensors consistently demonstrating stable calibration to within 5%the Landsat 7 ETM+ (Enhanced Thematic Mapper Plus), Landsat 8 OLI (Operational Land Imager), Terra MODIS (Moderate Resolution Imaging Spectroradiometer) and Sentinel-2A MSI (Multispectral Instrument)were merged into a seamless dataset. Instead of using the traditional method of trend analysis (Students T test), a nonparametric Seasonal Mann-Kendall test was used for determining the PICS stability. The analysis results indicate that Libya 4 and Egypt 1 do not exhibit any monotonic trend in six reflective solar bands common to all of the studied sensors, indicating temporal stability. A decreasing monotonic trend was statistically detected in all bands, except SWIR 2, for Sudan 1 and the Green and Red bands for Niger 1. An increasing trend was detected in the Blue band for Niger 2 and the NIR band for Libya 1. These results do not suggest abandoning PICS as a viable calibration source. Rather, they indicate that PICS temporal stability cannot be assumed and should be regularly monitored as part of the sensor calibration process

    reflectance spectra measurements of mt etna a comparison with multispectral hyperspectral satellite

    Get PDF
    We present a collection of eight reflectance spectra representative of Mt. Etna volcano lava flows. The reflectance spectra were measured with a FieldSpecPro from 350 nm to 2500 nm during a fieldwork in June 2007. The reflectance has been compared with reflectance obtained by multispectral Advanced Space borne Thermal Emission and Reflection Radiometer (ASTER) and by hyper spectral EO1-Hyperion satellites. Prior the comparison, reflectance spectra have been convolved with ASTER and EO1-Hyperion spectral functions. The results show percentage errors in accordance to those present in literature in the ASTER SWIR range. However, some differences have been confirmed for the ASTER reflectance product (ASTER_07) in visible channels. Regarding EO1-Hyperion, a good agreement of reflectance against field measurement has been found resulting in 5% percentage maximum error in the VIS and up 30% in SWIR spectral range. The capacity of reproducing spectral feature by EO1-Hyperion has been checked on bright pixels (ice-snow) in the acquired image
    corecore