286 research outputs found

    PMU-Based ROCOF Measurements: Uncertainty Limits and Metrological Significance in Power System Applications

    Full text link
    In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF-based applications, with a specific focus on Under-Frequency Load-Shedding (UFLS). For this analysis, we select three state-of-the-art window-based synchrophasor estimation algorithms and compare different signal models, ROCOF estimation techniques and window lengths in datasets inspired by real-world acquisitions. In this sense, we are able to carry out a sensitivity analysis of the behavior of a PMU-based UFLS control scheme. Based on the proposed results, PMUs prove to be accurate ROCOF meters, as long as the harmonic and inter-harmonic distortion within the measurement pass-bandwidth is scarce. In the presence of transient events, the synchrophasor model looses its appropriateness as the signal energy spreads over the entire spectrum and cannot be approximated as a sequence of narrow-band components. Finally, we validate the actual feasibility of PMU-based UFLS in a real-time simulated scenario where we compare two different ROCOF estimation techniques with a frequency-based control scheme and we show their impact on the successful grid restoration.Comment: Manuscript IM-18-20133R. Accepted for publication on IEEE Transactions on Instrumentation and Measurement (acceptance date: 9 March 2019

    Pattern Mining and Anomaly Detection based on Power System Synchrophasor Measurements

    Get PDF
    Real-time monitoring of power system dynamics using phasor measurement units (PMUs) data improves situational awareness and system reliability, and helps prevent electric grid blackouts due to early anomaly detection. The study presented in this paper is based on real PMU measurements of the U.S. Western Interconnection system. Given the nonlinear and non-stationary PMU data, we developed a robust anomaly detection framework that uses wavelet-based multi-resolution analysis with moving-window-based outlier detection and anomaly scoring to identify potential PMU events. Candidate events were evaluated via spatiotemporal correlation analysis and classified for a better understanding of event types, resulting in successful anomaly detection and classification of the recorded events

    Vulnerability Assessment and Privacy-preserving Computations in Smart Grid

    Get PDF
    Modern advances in sensor, computing, and communication technologies enable various smart grid applications which highlight the vulnerability that requires novel approaches to the field of cybersecurity. While substantial numbers of technologies have been adopted to protect cyber attacks in smart grid, there lacks a comprehensive review of the implementations, impacts, and solutions of cyber attacks specific to the smart grid.In this dissertation, we are motivated to evaluate the security requirements for the smart grid which include three main properties: confidentiality, integrity, and availability. First, we review the cyber-physical security of the synchrophasor network, which highlights all three aspects of security issues. Taking the synchrophasor network as an example, we give an overview of how to attack a smart grid network. We test three types of attacks and show the impact of each attack consisting of denial-of-service attack, sniffing attack, and false data injection attack.Next, we discuss how to protect against each attack. For protecting availability, we examine possible defense strategies for the associated vulnerabilities.For protecting data integrity, a small-scale prototype of secure synchrophasor network is presented with different cryptosystems. Besides, a deep learning based time-series anomaly detector is proposed to detect injected measurement. Our approach observes both data measurements and network traffic features to jointly learn system states and can detect attacks when state vector estimator fails.For protecting data confidentiality, we propose privacy-preserving algorithms for two important smart grid applications. 1) A distributed privacy-preserving quadratic optimization algorithm to solve Security Constrained Optimal Power Flow (SCOPF) problem. The SCOPF problem is decomposed into small subproblems using the Alternating Direction Method of Multipliers (ADMM) and gradient projection algorithms. 2) We use Paillier cryptosystem to secure the computation of the power system dynamic simulation. The IEEE 3-Machine 9-Bus System is used to implement and demonstrate the proposed scheme. The security and performance analysis of our implementations demonstrate that our algorithms can prevent chosen-ciphertext attacks at a reasonable cost

    Undetectable GPS-Spoofing Attack on Time Series Phasor Measurement Unit Data

    Full text link
    The Phasor Measurement Unit (PMU) is an important metering device for smart grid. Like any other Intelligent Electronic Device (IED), PMUs are prone to various types of cyberattacks. However, one form of attack is unique to the PMU, the GPS-spoofing attack, where the time and /or the one second pulse (1 PPS) that enables time synchronization are modified and the measurements are computed using the modified time reference. This article exploits the vulnerability of PMUs in their GPS time synchronization signal. At first, the paper proposes an undetectable gradual GPS-spoofing attack with small incremental angle deviation over time. The angle deviation changes power flow calculation through the branches of the grids, without alerting the System Operator (SO) during off-peak hour. The attacker keeps instigating slow incremental variation in power flow calculation caused by GPS-spoofing relentlessly over a long period of time, with a goal of causing the power flow calculation breach the MVA limit of the branch at peak-hour. The attack is applied by solving a convex optimization criterion at regular time interval, so that after a specific time period the attack vector incurs a significant change in the angle measurements transmitted by the PMU. Secondly, while the attack modifies the angle measurements with GPS-spoofing attack, it ensures the undetectibility of phase angle variation by keeping the attack vector less than attack detection threshold. The proposed attack model is tested with Weighted Least Squared Error (WLSE), Kalman Filtering, and Hankel-matrix based GPS-spoofing attack detection models. Finally, we have proposed a gradient of low-rank approximation of Hankel-matrix based detection method to detect such relentless small incremental GPS-spoofing attack

    Parallel detrended fluctuation analysis for fast event detection on massive PMU data

    Get PDF
    ("(c) 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works.")Phasor measurement units (PMUs) are being rapidly deployed in power grids due to their high sampling rates and synchronized measurements. The devices high data reporting rates present major computational challenges in the requirement to process potentially massive volumes of data, in addition to new issues surrounding data storage. Fast algorithms capable of processing massive volumes of data are now required in the field of power systems. This paper presents a novel parallel detrended fluctuation analysis (PDFA) approach for fast event detection on massive volumes of PMU data, taking advantage of a cluster computing platform. The PDFA algorithm is evaluated using data from installed PMUs on the transmission system of Great Britain from the aspects of speedup, scalability, and accuracy. The speedup of the PDFA in computation is initially analyzed through Amdahl's Law. A revision to the law is then proposed, suggesting enhancements to its capability to analyze the performance gain in computation when parallelizing data intensive applications in a cluster computing environment

    Performance Improvement of Wide-Area-Monitoring-System (WAMS) and Applications Development

    Get PDF
    Wide area monitoring system (WAMS), as an application of situation awareness, provides essential information for power system monitoring, planning, operation, and control. To fully utilize WAMS in smart grid, it is important to investigate and improve its performance, and develop advanced applications based on the data from WAMS. In this dissertation, the work on improving the WAMS performance and developing advanced applications are introduced.To improve the performance of WAMS, the work includes investigation of the impacts of measurement error and the requirements of system based on WAMS, and the solutions. PMU is one of the main sensors for WAMS. The phasor and frequency estimation algorithms implemented highly influence the performance of PMUs, and therefore the WAMS. The algorithms of PMUs are reviewed in Chapter 2. To understand how the errors impact WAMS application, different applications are investigated in Chapter 3, and their requirements of accuracy are given. In chapter 4, the error model of PMUs are developed, regarding different parameters of input signals and PMU operation conditions. The factors influence of accuracy of PMUs are analyzed in Chapter 5, including both internal and external error sources. Specifically, the impacts of increase renewables are analyzed. Based on the analysis above, a novel PMU is developed in Chapter 6, including algorithm and realization. This PMU is able to provide high accurate and fast responding measurements during both steady and dynamic state. It is potential to improve the performance of WAMS. To improve the interoperability, the C37.118.2 based data communication protocol is curtailed and realized for single-phase distribution-level PMUs, which are presented in Chapter 7.WAMS-based applications are developed and introduced in Chapter 8-10. The first application is to use the spatial and temporal characterization of power system frequency for data authentication, location estimation and the detection of cyber-attack. The second application is to detect the GPS attack on the synchronized time interval. The third application is to detect the geomagnetically induced currents (GIC) resulted from GMD and EMP-E3. These applications, benefited from the novel PMU proposed in Chapter 6, can be used to enhance the security and robust of power system
    corecore