278 research outputs found

    Innovative robot hand designs of reduced complexity for dexterous manipulation

    Get PDF
    This thesis investigates the mechanical design of robot hands to sensibly reduce the system complexity in terms of the number of actuators and sensors, and control needs for performing grasping and in-hand manipulations of unknown objects. Human hands are known to be the most complex, versatile, dexterous manipulators in nature, from being able to operate sophisticated surgery to carry out a wide variety of daily activity tasks (e.g. preparing food, changing cloths, playing instruments, to name some). However, the understanding of why human hands can perform such fascinating tasks still eludes complete comprehension. Since at least the end of the sixteenth century, scientists and engineers have tried to match the sensory and motor functions of the human hand. As a result, many contemporary humanoid and anthropomorphic robot hands have been developed to closely replicate the appearance and dexterity of human hands, in many cases using sophisticated designs that integrate multiple sensors and actuators---which make them prone to error and difficult to operate and control, particularly under uncertainty. In recent years, several simplification approaches and solutions have been proposed to develop more effective and reliable dexterous robot hands. These techniques, which have been based on using underactuated mechanical designs, kinematic synergies, or compliant materials, to name some, have opened up new ways to integrate hardware enhancements to facilitate grasping and dexterous manipulation control and improve reliability and robustness. Following this line of thought, this thesis studies four robot hand hardware aspects for enhancing grasping and manipulation, with a particular focus on dexterous in-hand manipulation. Namely: i) the use of passive soft fingertips; ii) the use of rigid and soft active surfaces in robot fingers; iii) the use of robot hand topologies to create particular in-hand manipulation trajectories; and iv) the decoupling of grasping and in-hand manipulation by introducing a reconfigurable palm. In summary, the findings from this thesis provide important notions for understanding the significance of mechanical and hardware elements in the performance and control of human manipulation. These findings show great potential in developing robust, easily programmable, and economically viable robot hands capable of performing dexterous manipulations under uncertainty, while exhibiting a valuable subset of functions of the human hand.Open Acces

    Rehabilitation Engineering

    Get PDF
    Population ageing has major consequences and implications in all areas of our daily life as well as other important aspects, such as economic growth, savings, investment and consumption, labour markets, pensions, property and care from one generation to another. Additionally, health and related care, family composition and life-style, housing and migration are also affected. Given the rapid increase in the aging of the population and the further increase that is expected in the coming years, an important problem that has to be faced is the corresponding increase in chronic illness, disabilities, and loss of functional independence endemic to the elderly (WHO 2008). For this reason, novel methods of rehabilitation and care management are urgently needed. This book covers many rehabilitation support systems and robots developed for upper limbs, lower limbs as well as visually impaired condition. Other than upper limbs, the lower limb research works are also discussed like motorized foot rest for electric powered wheelchair and standing assistance device

    The effects on biomechanics of walking and balance recovery in a novel pelvis exoskeleton during zero-torque control

    Get PDF
    Fall-related accidents are among the most serious concerns in elderly people, amputees and subjects with neurological disorders. The aim of this paper was to investigate the behaviour of healthy subjects wearing a novel light-weight pelvis exoskeleton controlled in zero-torque mode while carrying out unperturbed locomotion and managing unexpected perturbations. Results showed that the proposed exoskeleton was unobtrusive and had a minimum loading effect on the human biomechanics during unperturbed locomotion. Conversely, it affected the movement of the trailing leg while subjects managed unexpected slipping-like perturbations. These findings support further investigations on the potential use of powered exoskeletons to assist locomotion and, possibly prevent incipient fall

    Continuous Proportional Myoelectric Control of an Experimental Powered Lower Limb Prosthesis During Walking Using Residual Muscles.

    Full text link
    Current robotic lower limb prostheses rely on intrinsic sensing and finite state machines to control ankle mechanics during walking. State-based controllers are suitable for stereotypical cyclic locomotor tasks (e.g. walking on level ground) where joint mechanics are well defined at specific gait phases (i.e. states) and state transitions are easily detected. However, state-based controllers are not ideal for non-stereotypical acyclic tasks (e.g. freestyle dancing) where joint mechanics cannot be predefined and transitions are unpredictable. An alternative to state-based control is to utilize the amputee's nervous system for myoelectric control. A robotic lower limb prosthesis that uses continuous proportional myoelectric control would allow the amputee to adapt their ankle mechanics freely. One potential source for myoelectric control is the amputee’s residual muscles. I conducted four studies to examine the feasibility of using residual muscles for continuous myoelectric control during walking. In my first study, I demonstrated that it is possible to record residual electromyography from amputees during walking that are viable for continuous myoelectric control. My results showed that the stride-to-stride variability of residual and intact muscle activation patterns was similar. However, residual muscle activation patterns were significantly different across amputee subjects and significantly different than corresponding muscles in intact subjects. In my second study, I built and tested an experimental powered transtibial prosthesis and demonstrated that an amputee subject was able to walk using continuous proportional myoelectric control to alter prosthetic ankle mechanics. In my third study, I showed that five amputee subjects were able to adapt their residual muscles to walk using continuous proportional myoelectric control. With visual feedback of their control signal, amputees were able to generate higher peak ankle power walking with the experimental powered prosthesis compared to their prescribed prosthesis. In my fourth study, I conducted a user experience study and found that despite challenges with the device user interface, walking with continuous proportional myoelectric control gave amputees a sense of empowerment and embodiment. The results of my studies demonstrated the advantages and disadvantages of using continuous proportional myoelectric control for a powered transtibial prosthesis and suggest how next generation prostheses can build upon these findings.PHDBiomedical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/110412/1/shuangz_1.pd

    Biomechatronics: Harmonizing Mechatronic Systems with Human Beings

    Get PDF
    This eBook provides a comprehensive treatise on modern biomechatronic systems centred around human applications. A particular emphasis is given to exoskeleton designs for assistance and training with advanced interfaces in human-machine interaction. Some of these designs are validated with experimental results which the reader will find very informative as building-blocks for designing such systems. This eBook will be ideally suited to those researching in biomechatronic area with bio-feedback applications or those who are involved in high-end research on manmachine interfaces. This may also serve as a textbook for biomechatronic design at post-graduate level

    Full Issue: Volume 8, Number 1

    Get PDF
    corecore