79,803 research outputs found

    Computational tools for low energy building design : capabilities and requirements

    Get PDF
    Integrated building performance simulation (IBPS) is an established technology, with the ability to model the heat, mass, light, electricity and control signal flows within complex building/plant systems. The technology is used in practice to support the design of low energy solutions and, in Europe at least, such use is set to expand with the advent of the Energy Performance of Buildings Directive, which mandates a modelling approach to legislation compliance. This paper summarises IBPS capabilities and identifies developments that aim to further improving integrity vis-Ć -vis the reality

    A rational approach to the harmonisation of the thermal properties of building materials

    Get PDF
    The Energy Systems Research Unit at the University of Strathclyde in Glasgow was contracted by the Building Research Establishment to review existing data-sets of thermo-physical properties of building materials and devise vetting and conflation mechanisms. The UK Chartered Institute of Building Services Engineers subsequently commissioned a project to extract a sub-set of these data for inclusion in Guide A, Section 3. This paper reports the project process and outcome. Specifically, it describes the source of existing data, comments on the robustness of the underlying test procedures and presents a new approach to data classification and conflation

    Post-test simulation of a PLOFA transient test in the CIRCE-HERO facility

    Get PDF
    CIRCE is a leadā€“bismuth eutectic alloy (LBE) pool facility aimed to simulate the primary system of a heavy liquid metal (HLM) cooled pool-type fast reactor. The experimental facility was implemented with a new test section, called HERO (Heavy liquid mEtal pRessurized water cOoled tubes), which consists of a steam generator composed of seven double-wall bayonet tubes (DWBT) with an active length of six meters. The experimental campaign aims to investigate HERO behavior, which is representative of the tubes that will compose ALFRED SG. In the framework of the Horizon 2020 SESAME project, a transient test was selected for the realization of a validation benchmark. The test consists of a protected loss of flow accident (PLOFA) simulating the shutdown of primary pumps, the reactor scram and the activation of the DHR system. A RELAP5-3DĀ© nodalization scheme was developed in the pre-test phase at DIAEE of ā€œSapienzaā€ University of Rome, providing useful information to the experimentalists. The model consisted to a mono-dimensional scheme of the primary flow path and the SG secondary side, and a multi-dimensional component simulating the large LBE pool. The analysis of experimental data, provided by ENEA, has suggested to improve the thermalā€“hydraulic model with a more detailed nodalization scheme of the secondary loop, looking to reproduce the asymmetries observed on the DWBTs operation. The paper summarizes the post-test activity performed in the frame of the H2020 SESAME project as a contribution of the benchmark activity, highlighting a global agreement between simulations and experiment for all the primary circuit physical quantities monitored. Then, the attention is focused on the secondary system operation, where uncertainties related to the boundary conditions affect the computational results

    Experimental investigation of ventilation efficiency in a dentistry surgical room

    Get PDF
    As a response to the need to provide an acceptable thermal comfort and air quality in indoor environments, various ventilation performance indicators were developed over the years. These metrics are mainly geared towards air distribution, heat and pollutant removals. Evidence exists of influencing factors on these indicators as centered on ventilation design and operations. Unlike other indoor environments, health care environment requires better performance of ventilation system to prevent an incidence of nosocomial and other hospital acquired illnesses. This study investigates, using in-situ experiments, the ventilation efficiency in a dentistry surgical room. Thermal and hygric parameters were monitored on the air terminal devices and occupied zone over a period of one week covering both occupied and unoccupied hours. The resulting time-series parameters were used to evaluate the room's ventilation effectiveness. Also, the obtained parameters were benchmarked against ASHRAE 170 (2013) and MS1525 (2014) requirements for ventilation in health care environment and building energy efficiency respectively. The results show that the mean daily operative conditions failed to satisfy the provisions of both standards. Regarding effectiveness, the findings reveal that the surgical room ventilation is ineffective with ventilation efficiency values ranging between 0 and 0.5 indicating air distribution short-circuiting. These results suggest further investigations, through numerical simulation, on the effect of this short-circuiting on thermal comfort, infection risk assessments and possible design improvements, an endeavour that forms our next line of research inquiries

    Assessing and benchmarking the performance of advanced building facades

    Get PDF
    This chapter describes the energy demand reshaping and supply technologies that may be encapsulated within an advanced building faƧade - for example, transparent and breathable insulation, advanced glazing, daylight capture, photovoltaic components and ducted wind turbines. Laboratory testing techniques for the characterisation of the fundamental parameters underlying each technology are elaborated as the essential prerequisite of integrated performance appraisals of specific technology combinations within an advanced faƧade design context. Based on the results from simulations undertaken in the UK climate context, performance benchmarks are suggested for some principal faƧade configurations

    Case studies of outdoor testing and analysis of building components

    Get PDF
    The construction and development of the PASSYS/PASLINK outdoor test cells were funded by the European Commission, with the objective of providing high-quality test environments for quantifying the performance of passive solar building components. Over the years since the original test cells were commissioned, the initial concept for outdoor testing has been extended to include other test cell types. Significant improvements have been made to the experimental procedures and analysis techniques, and a broad range of components has been tested. This paper describes representative experiments that have been conducted using these highly controlled outdoor test environments, indicates some of the related analysis, and shows the type of information that can be obtained from such tests. It demonstrates the way in which component performance can be ascertained in the realistic external environment. The case studies chosen range from building component tests within EC research projects to commercial tests, and from conventional building components to novel integrated facade systems. They also include a large range of passive and active components. Each case study summarises the test component, the purpose of the test, details of the test configuration (period of test, instrumentation, etc.), results and analysis, and associated modelling and monitoring where appropriate. The paper concludes with an appraisal of the advantages and limitations of the test cells for the various component types

    Towards measurement and verification of energy performance under the framework of the European directive for energy performance of buildings

    Get PDF
    Directive 2002/91/EC of the European Parliament and Council on the Energy Performance of Buildings has led to major developments in energy policies followed by the EU Member States. The national energy performance targets for the built environment are mostly rooted in the Building Regulations that are shaped by this Directive. Article 3 of this Directive requires a methodology to calculate energy performance of buildings under standardised operating conditions. Overwhelming evidence suggests that actual energy performance is often significantly higher than this standardised and theoretical performance. The risk is national energy saving targets may not be achieved in practice. The UK evidence for the education and office sectors is presented in this paper. A measurement and verification plan is proposed to compare actual energy performance of a building with its theoretical performance using calibrated thermal modelling. Consequently, the intended vs. actual energy performance can be established under identical operating conditions. This can help identify the shortcomings of construction process and building procurement. Once energy performance gap is determined with reasonable accuracy and root causes identified, effective measures could be adopted to remedy or offset this gap

    COAPEC: Newsletter No. 4

    Get PDF
    The fourth of an irregular series of Newsletters with brief reports on meetings and projects associated with the NERCā€™s COAPEC directed programme. Article: Programme News Article: Bjerknes Compensation and the Decadal Variability of Energy Transports in a Coupled Climate Model Article: Probabilistic Attribution of the UK Autumn 2000 Floods using a Forecast Resolution Global Atmospheric Climate Model and Distributed Computing Article: Accuracy of Sea-Ice Observations and Impact on GCM Simulations Article: Use of Spatially Dependent Inverse Analysis Techniques to Close the SOC Flux Climatology Ocean Heat Budget Article: The Hot Summer of 2003 Article: COAPEC Data Article: The PRECIS Regional Modelling System Article: Meetings and Workshop

    Effectiveness of CFD simulation for the performance prediction of phase change building boards in the thermal environment control of indoor spaces

    Get PDF
    This is the post-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2013 ElsevierThis paper reports on a validation study of CFD models used to predict the effect of PCM clay boards on the control of indoor environments, in ventilated and non-ventilated situations. Unlike multi-zonal models, CFD is important in situations where localised properties are essential such as in buildings with complex and large geometries. The employed phase change model considers temperature/enthalpy hysteresis and varying enthalpy-temperature characteristics to more accurately simulate the phase change behaviour of the PCM boards compared to the standard default modelling approach in the commercial CFD codes. Successful validation was obtained with a mean error of 1.0 K relative to experimental data, and the results show that in addition to providing satisfactory quantitative results, CFD also provides qualitative results which are useful in the effective design of indoor thermal environment control systems utilising PCM. These results include: i) temperature and air flow distribution within the space resulting from the use of PCM boards and different night ventilation rates; ii) the fraction of PCM experiencing phase change and is effective in the control of the indoor thermal environment, enabling optimisation of the location of the boards; and iii) the energy impact of PCM boards and adequate ventilation configurations for effective night charging.This work was funded through sponsorship from the UK Engineering and Physical Sciences Research Council (EPSRC), Grant No: EP/H004181/1

    Numerical modelling of the temperature distribution in a two-phase closed thermosyphon

    Get PDF
    Interest in the use of heat pipe technology for heat recovery and energy saving in a vast range of engineering applications has been on the rise in recent years. Heat pipes are playing a more important role in many industrial applications, particularly in improving the thermal performance of heat exchangers and increasing energy savings in applications with commercial use. In this paper, a comprehensive CFD modelling was built to simulate the details of the two-phase flow and heat transfer phenomena during the operation of a wickless heat pipe or thermosyphon, that otherwise could not be visualised by empirical or experimental work. Water was used as the working fluid. The volume of the fluid (VOF) model in ANSYS FLUENT was used for the simulation. The evaporation, condensation and phase change processes in a thermosyphon were dealt with by adding a user-defined function (UDF) to the FLUENT code. The simulation results were compared with experimental measurements at the same condition. The simulation was successful in reproducing the heat and mass transfer processes in a thermosyphon. Good agreement was observed between CFD predicted temperature profiles and experimental temperature data.The Saudi Cultural Bureau in London, the Ministry of Higher Education and the Mechanical Engineering Department, Umm Al-Qura University
    • ā€¦
    corecore